Huato A2000 Series Operation Manual

Huato A2000 Series Operation Manual

Digital alarm-hygrometer
Hide thumbs Also See for A2000 Series:

Advertisement

Operation manual for A2000 series Digital Alarm-hygrometer
Thank you for purchasing HUATO A2000 series digital alarm-hygrometer. This product
is featured monitoring environment temperature and humidity and alarm when the
value exceeds the setting limits. We believe HUATO products can satisfy your
requirements perfectly.

1. Product Features

n
Fahrenheit and Celsius are available.
n
Large LCD display temperature, humidity, data and time as well as date
simultaneously.
n
Elegant appearance design, desktop and wall-mounted are available.
n
Built-in audible and visual alarm and limit alarm.

2. Applications

It has been widely applied in medical field, warehouse, office, lab and agricultural
industry etc.

3. Technical Specifications

Model
Temperature
accuracy
Humidity accuracy
Sensor type
Temperature
measuring range
Humidity
measuring range
Introduction
A2000-TH
A2000-EX A2000-TB A2000-EB A2000-TS A2000-ES
±0.5℃
±0.5℃
±5%RH
±5%RH
Internal
External
-20~70℃
-40~85℃
--------P.1--------
±0.3℃
±0.5℃
±3%RH
±3%RH
Internal
External
-20~70℃
-40~85℃
0~100%RH
±0.2℃
±0.2℃
±2%RH
±2%RH
Internal
External
-20~70℃
-40~85℃

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A2000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Huato A2000 Series

  • Page 1 Operation manual for A2000 series Digital Alarm-hygrometer Introduction Thank you for purchasing HUATO A2000 series digital alarm-hygrometer. This product is featured monitoring environment temperature and humidity and alarm when the value exceeds the setting limits. We believe HUATO products can satisfy your requirements perfectly.
  • Page 2 Operation manual for A2000 series Digital Alarm-hygrometer 4. Brief introduction for A2000 structure LCD display DC 12V Menu Reset Max/Min Hanger Backlight button Holder ON/OFF Battery cover Install battery and mounting dimension --------P.2--------...
  • Page 3 Operation manual for A2000 series Digital Alarm-hygrometer 6. LCD symbols instructions Backlight Alarm when the value exceeds the setting limits. Press MAX and display the maximum value. Press MIN and display the minimum value, press again and them show the current value.
  • Page 4 Operation manual for A2000 series Digital Alarm-hygrometer 7. Buttons Instructions : Setup key, press this key, the hygrometer enters into setting status and customers can set temperature and humidity high and low limits, alarm function, clock as well as re-calibration setup.

This manual is also suitable for:

A2000-thA2000-exA2000-tbA2000-ebA2000-tsA2000-es

Table of Contents

Save PDF