Summary of Contents for Microsemi SyncSystem 4380A
Page 1
SyncSystem 4380A Operations and Maintenance Manual Ju1 2017 Part Number: 098‐00723‐000 Manual updates are available at: www.microsemi.com/ftdsupport...
Page 3
This is the first release of this document. Related Documents and Information See your Microsemi representative or sales office for a complete list of available documentation. To order any accessory, contact the Microsemi Sales Department. See www.microsemi.com/salescontacts/ for sales support contact information. If you encounter any difficulties installing or using the product, contact Microsemi Frequency and Time Division (FTD) Services and Support: U.S.A.
Page 4
4380A O & M Manual Revision History Revision Description Date Approved Initial Release Feb 2016 Updated performance specifications & CE Documentation May2016 Updated safety and fuse rating information Jun 2016 Software Version 1.1 Jul 2017 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Antenna Delay Calibration ................. 24 On Time Point (OTP) ..................25 Using an External Frequency Reference: ............26 Setting the System Time Manually ..............28 2.9.1 Force Time ....................28 2.9.2 External Reference ..................28 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 6
System Verification .................... 49 Theory of Operations ...................... 58 Generation of Timing Signals ................58 GPS ........................58 Output Signals ....................58 GPS Data Collection ..................59 Startup Sequence ....................59 Maintenance ........................61 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
All units include the antenna, USB dongles, 94020 Rail Kits, network time protocol (NTP), Ethernet control, and data logging capabilities. Contact Microsemi (www.microsemi.com) for current pricing and availability. The 94000-115200 and 94001-5071A USB Dongles are DTE devices; this may require the use of a null modem serial cable.
All of the modules and power supplies are safetly hot swappable, operators are only required to power the system off when removing it from an equipment rack or when turning the system off. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
4380A à fonctionner, le système restera dans ce mode jusqu'à ce que l’antenne est correctement configuré. Cela empêche le système de potentiellement endommager toute antenne jusqu'à ce que la tension d’alimentation antenne est correctement définie par l’utilisateur final. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
If not, you may need to power the system down, plug the cable in and re-apply power. The USB/Serial Cables are programmed to provide users access to the command port 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
E. Users can also view the current network settings using the network command. This will display the current user settings. 4380A-G1R>network [ipv6] auto [mode] static [static] [broadcast] 192.168.150.255 [default_gateway] 192.168.150.1 [ip] 192.168.150.64 [netmask] 255.255.255.0 [OK] 2017-07-03T15:09:43Z 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The 4380A to communicate with a 5071A Cesium Clock (94001-5071A). See section 2.7. Note: Microsemi recommends if you are going to use these cables that the cables should be plugged into the unit when it is powered on. Antenna Installation Installing the antenna properly requires careful planning.
Another consideration when installing the line amplifier is how it will receive power. Some amplifiers are powered using a DC bias on the antenna cable and others are 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
DOC 4380A 4380A O & M Manual powered from AC adapters directly. Please contact Microsemi if you require assistance in selecting the right amplifier for your application. 4380A Line Amp ANTENNA Figure 3 Antenna Cable The antenna mount should be secured to a stable structure such as a building, antenna mast, or other suitable mounting platform.
The Dynamic mode is typically used for systems located on mobile platforms. NOTICE The system default mode is dynamic. Users at static locations should change this to auto or manual based on the information provided below. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The file will be in the “rinex” subdirectory and will have a “.[yy]o” extension where [yy] represents the last digits current year. Many online processing centers available (e.g., http://www.ngs.noaa.gov/OPUS, http://sopac.ucsd.edu/cgi-bin/SCOUT.cgi) will process observation file free of charge. Doing this improves the position estimate of the antenna and is 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
[OK] 2015-08-05T15:36:14Z 4380A>status gps:mode:desc tracking [OK] 2015-08-05T15:37:27Z To manually set the antenna position, use the following steps: A. Select the proper datum, WGS84 (default) or NAD83, using the datum command. 4380A>datum wgs84 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 21
The operator also has the option of setting the manual mode and entering all three parameters on the same command line using the fix_position (current | lat, lon, alt) command. 4380A> fix_position 38.46627893094 -77.44086542274004 51.573999999999998 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Power Supply #1 is on the left and Power Supply #2 is on the right when looking at the front of the unit. See Appendix A for the specifications on the Power Supplies. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Usage: <slot#> <port#> <pulse period> <pulse width> [ERROR] 2015-08-05T15:53:07Z To verify the settings use the settings hardware:slots:N command (where N=Slot #) to obtain the current settings for a particular card. 4380A> settings hardware:slots:1 [4394A] [ports] 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 24
To verify the card is working properly, use the status hardware:outputs:slots:N command (where N=Slot #) to obtain the current settings for a particular card. 4380A>status hardware:outputs:slots:1 [ports] [status] good [status] good [status] good [status] good [power] enabled [type] 4394A 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
To verify the settings use the settings hardware:slots:N command (where N=Slot #) to obtain the current settings for a particular card. 4380A>settings hardware:slots:5 [tsc4376] [ports] [pps_period] 1.000000000000000e+00 [pps_width] 1.000000000000000e-04 [type] pps [pps_period] 1.000000000000000e+00 [pps_width] 1.000000000000000e-04 [type] pps [format] B 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
To verify these cards are working properly, use the status hardware:outputs:slots:N command (N = slot number) to obtain the current status for a particular card. 4380A>status hardware:outputs:slots:3 [ports] [status] good [status] good [status] good [status] good [power] enabled [type] 4395A-10 [OK] 2015-08-05T16:06:29Z 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The system will generate an error message if the operator attempts to enter an unsupported or invalid code. To verify the settings, use the settings hardware:slots:N command (where N=Slot #) to obtain the current settings for a particular card. 4380A>settings hardware:slots:5 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 29
Moving the output module to a different slot causes the system to configure the module with the default output format(s) until that card slot is properly configured by the user. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
To verify the output card settings use the settings hardware:slots:N command where N is the slot # where the 4374A card is installed. 4380A>settings hardware:slots:3 [tsc4374] [ports] [enabled] true [mode] 0 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
To verify the card is working properly, use the status hardware:outputs:slots:N command (N=Slot #) to obtain the current status for a particular card. 4380A>status hardware:outputs:slots:4 [ports] [status] good [status] good [status] good [status] good 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
OTP; users should refer to section 2.7 for information on changing the location of the OTP for the system. For applications requiring the highest level of accuracy, the 4380A should be calibrated at Microsemi. This process involves installing the user’s antenna and antenna cable at the factory and comparing the PPS outputs to a system which has a known offset to UTC(USNO).
4380A to the user inputs. In moving the OTP of the system, it is imperative that the distribution delays from the 4380A to each of the users is equal. This will ensure that all users receive accurate timing signals. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
4380A via a RS232 connection through either of the USB Connectors on the rear of the unit (94001-5071A). The Microsemi 5071A is currently the only model supported; users should contact Microsemi about the possibility of utilizing other clocks. The serial port on the 5071A must be set to 9600 Baud, No Parity, 8 Data Bits, and 1 Stop Bit (9600,N,8,1) and a null modem serial cable will be required.
Page 35
(94000-115200). These cables are NOT interchangeable. To set the type of reference, use the reference_type command. If users are operating with a Microsemi 5071A and they will set the system up so the 4380A is communicating with the 5071A, select hp5071A, if not select cesium.
Users will need to edit the node.cfg file to use one or more 1PPS references from the 4393A Card as a steer source. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The system will recognize case sensitive alphanumeric characters, -, ‘ ‘, and _. If any other characters are used, the system will inform the user that the filename is not valid and will not save the settings. 4380A>save te%^$st Illegal Filename [ERROR] 2015-08-05T17:29:17Z 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
If there are no user configuration files available the system will report no files. 4380A>list_logs ftp 4380A>list_logs rt default default or if there are no log settings files, 4380A>list_logs ftp no files 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 39
4380A>delete_logs ftp example [OK] 2010-05-25T17:33:43Z 4380A>delete_logs ftp <ftp | rt> FILENAME FILENAME Name of file [ERROR] 2015-08-05T20:55:19Z 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
If configuration errors are detected the system will light the front panel alarm light and the alarms command will provide an indication of the error. 4380A>alarm [alarm] syscfg -- Incorrect format in slot 6 port 2: expected=B, actual=H [OK] 2013-09-05T23:54:07Z 4380A>alarms [syscfg] [occurrences] 1 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
2.11 Powering the System Off To remove power from the 4380A remove the input power sources from Power Supply #1 and #2. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The SYNC indicator on the 4380A shall indicate the current status of the internal, external, steer source, or timescale references. Indications shall be based on the reference type currently in use as specified by the operator. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
(5071A). The GPS Antenna connector is used to connect the GPS Antenna to the system. The 10MHz IN connector is used to provide the 10MHz signal input from an external frequency reference. See the figure below. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The system network and user configuration settings are NOT saved and the system will need to be set up. Les arrangements de configuration de réseau et d'utilisateur de système ne sont pas sauvés et le système devra être établi. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
FPGA warmstart register has been cleared; a coldstart will occur common_updater.sh: Cleaning up temporary files and flushing all data to disk common_updater.sh: Setting bootable flag in partition 2 common_updater.sh: UPDATE SUCCESSFUL Outputs disabled Warm start successfully disabled Rebooting... [OK] 2015-08-05T15:17:53Z 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
~2 minutes. Once the SYNC light is on it will take an additional 1.5 to 2 minutes for NTP to lock and for the outputs to be enabled. Users can obtain the new software image and software release notes from Microsemi http://ftd.microsemi.com/time >Products >...
Manual Time Setting Commands force time Manually set the time and enable outputs when GPS is not available adjust_time Manually adjust the time in 1 second increments when in manual time mode 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 49
Allows the operator to set the IRIG codes on the 4394A (DC IRIG) and 4387A (AM IRIG) Cards. irig_input Allows the operator to set the IRIG input codes on the 4383A IRIG input Card. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Diagnostic messages are only displayed on the diagnostic port. If users wish to save the messages provided by the diagnostic port then the output of this port must be saved to a file. It is recommended that diagnostic 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Upload a new software version (.iso) and use the software_update command to update the system software. User name and password = update. Manage the systems mibs files (SNMP) 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
If the user wanted to look for the system uptime, the user would simply add a “:” then the sub-category under unit. Additional subcategories can be added to the command line, separated with the “:”. 4380A>status unit:uptime 3 days, 4 hours, 42 minutes [OK] 2015-08-07T20:41:43Z 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
When using the user file naming scheme you will also need to provide the file prefix, the number of digits you would like to use as the unique file identifier, and the suffix for the file. 4380A>log_filename user Test 4 dat 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 55
To delete the desired data type use the unlog ftp [datatype] command to remove the desired data from the list. Users can remove all of the log files simply using the unlog ftp all command. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
C. If needed, turn the real time logging on using the log_enable rt command. 4380A>log_enable rt 1 [OK] 2015-08-08T13:55:49Z D. You can verify the real time log settings using the settings gps_logging:rt command. 4380A>settings gps_logging:rt [enable] true 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
After the system installation and setup are complete, users can verify the system is operating properly by looking at several of the system operating parameters to verify the values are correct. If there are no red 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 58
The [gps] [satellite] [signal] [freq] field indicates whether single frequency or dual frequency measurements are being received from the receiver. If only single frequency measurements are being received then check the antenna and make sure that it is the Novatel (L1/L2) 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 59
The system will also report the internal temperature as measured by the unit. [temperature] 37 Each of the units hardware conditions is monitored and reported as system health should report false and have zero active errors. [health] [clock_freq_step] [active] false [occurrences] 0 [clock_phase_step] 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 60
[outputs unlocked] active blocks should be false. The [power supply] [0-1] active blocks should also be false. [output_modules] [active] false [occurrences] 0 [ports] [active] false [occurrences] 0 [active] false [occurrences] 0 [active] false 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 63
[clock] info [cpld4370] info [gps] info [kas2] debug [lnsrawstate] info [smcp] info [software] info [tagps] info [timecode] info [4380] info [tsgather] info [warmstart] info [gps] [antenna_delay] 2.374500000000000e-07 [antenna_voltage] 0.000000000000000e+00 [datum] wgs84 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 65
Note: If you do not save the user default settings the system will come up with the factory default values the next time the system reboots or is power cycled. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
OCXO control voltage is at a minimum or maximum value. The averaging of this control voltage provides more stable steering over time. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
GPS receiver which attempts to acquire and track the signal received from GPS satellites. This process usually takes 5 to 10 minutes but may take as long as 30 minutes depending upon 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Page 68
In these cases, a coarse adjustment of system time is performed and then the startup sequence is restarted. This process should only happen once and only in cases where the system has been powered off. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The recommended maintenance schedule for the 4380A is outlined in Table 6. Although this schedule is sufficient for most applications, it may be necessary to increase the number of scheduled maintenance events for extremely dusty or dirty environments. Contact Microsemi if there are questions about the scheduled maintenance cycle.
The possible problems are listed below: Power Supply has failed Internal Fuse is open Power Supply is unplugged, make sure the power supply is plugged in 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
FAULT. By using the status health:output_modules command and/or the syslog command and checking both the active = true and/or occurrences is greater than 0. 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
If set too high, the receiver will not be able to use all of the available satellites to determine a fix and determine the correct time. Ensure the mask angle is correct using the settings gps:mask_angle command. Default = 10 degrees. 4380A>settings gps:mask_angle 1.0000000000000000e+01 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Inspect the antenna cable and correct any issues and replace any cables that appear to be weathered. Improper Antenna Cable. The cable may be either too long or the improper type. Microsemi recommends using low loss coaxial cables for the GPS antenna cable. Cable losses cannot exceed 10dB when using the antenna supplied with the 4380A.
[OK] 2015-08-08T14:46:32Z Users can also check the status of the time scale to ensure the UTC offset value [ptd] is under +/- 100 ns from UTC and the clock is being steered 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
4380A>status hardware:fan [1] true [2] true Users can look to see if the unit had any issues with either of the fans by using the status health:fan command 4380A>status health:fan [active] false 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
[status] good [status] good [power] enabled [type] 4394A For a 4394A-ECL card: [ports] [status] good [status] good [status] n/a [status] n/a [power] enabled [type] 4394A-ECL For a 4376A-RS422 PPS card: [ports] 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
To verify the settings use the settings hardware:slots:N command (where N=Card Slot #) to verify the system settings. 4380A>settings hardware:slots:5 [tsc4387] [ports] [format] B 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
The internal bus used to communicate with the plug in modules and power supplies to determine their type and serial number is the I2C bus. If this alarm occurs the system should continue to operate correctly, but 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
2010-06-15-13:30:52 Jun 15 13:30:52 Sync System Sync System[536]: .001 0x0060e900 [Tsc4370] Sending time 2010-06-15-13:30:52 to the FPGA Jun 15 13:30:52 Sync System Sync System[536]: .007 0x0060e900 [GPSLogging] Starting GPS user logs 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Factory Default: /usr/tsc/syscfg/syscfg_default.py. This file should not be edited. These are the factory default settings for the unit. If necessary you can use this file as a reference guide. User File: /mod/tsc/syscfg/localcfg.py 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Client Support ~100 client requests per second File Transfer Protocol Log Files User:ftp, Password: ftp Software Update User: ftp, Password: ftp Ports Command Port 1700 Debug Port 1800 Status Port 1900 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
100 Ω Line to Line ( 10.0 ) Load Impedance Transition Time (20% 700 ps max. to 80 %) Voltage Output -1025 mv to -880 mv High(V Voltage Output -1810 mv to -1620 mv Low(V 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
This module provides four 5 MHz outputs. The module also monitors each output for levels below approximately 10 dBm, after which an alarm is raised. Characteristic Description Number of outputs Four Output connectors BNC(F) 50 Ω Impedance Amplitude +13 dBm +/- 2 dBm Signal Sine Wave 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Number of outputs Four Output connectors RF-45, Pin 4 TX Ring, Pin 5 TX tip 100 Ω Impedance Signal ANSI T1.102: Digital Hierarchy Electrical Interface Time Code None, frequency output only 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
> 2Vpk and < 5Vpk. AM Input Voltage (50 Ω) > 600mV pk-pk and < 6.0Vpk-pk. Time Codes B000 to B007 and B120 to B127 AM IRIG Ratio 2:1 to 4:1, Nominal 3:1 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
To avoid the risk of Electrical fire rplace the fuses with the SAME size, type, and rating ONLY. AC Input: Two 250V/1.5AT (Time delay) 5 x 20 mm DC Input: Two 250V/5AT (Time delay) 5 x 20 mm 098-00723-000– Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual...
Need help?
Do you have a question about the SyncSystem 4380A and is the answer not in the manual?