ON / OFF button
Priority light
In use light
Display panel
 (up button)
 (down button)
water volume button
Water volume notes:
The water volume function is designed to warn, by a beeping sound, that a certain volume
of water has been delivered from the water heater. It does not stop either the flow of
or the heating of water.
The Kitchen controller does not require priority nor to be on in order to set the water
volume function.
The water volume function can be set whilst a hot tap is open.
The water volume alarm will only sound from the kitchen controller.
The factory preset water volume is 180 litres.
To turn off the water volume function before the alarm sounds, press the water volume
button twice.
The water volume is measured as the water flows through the water heater. Therefore if
more than one hot tap is open, the alarm will respond to the total water volume drawn
from all taps and the expected water volume from the first tap will be decreased.
If the hot tap is closed before the set water volume flows through the water heater and
the water volume button is left on, then the alarm will sound when the remaining water
volume is consumed during a later operation. To prevent the alarm from sounding,
press the water volume button twice to turn it off.
TM090 12-26 Series II CFGWH Service Instructions
REV AB – Issued February 2019
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed "uncontrolled"
This button must be pressed once to turn on the controller. The light
in the button will glow when the controller is on. A controller cannot
be turned on if water is flowing from a hot tap. To turn off a controller,
press the on / off button once. The light will go out. A controller can
be turned off whilst water is flowing.
This light will glow on a controller when that controller has priority.
The Bathroom controller(s), if they are turned on, have priority over
the Kitchen controller. Priority means that controller has control of
the water heater temperature setting. The water temperature setting
can only be adjusted by the controller that has priority.
This light will glow on all controllers, whether they are on or off, when
hot water is flowing, regardless of which controller has priority.
The current temperature setting is displayed on all controllers
(whether hot water is flowing or not), when any controller is on. If all
controllers are off, then the display remains blank. The water volume
can also be displayed on the Kitchen controller. The x10l symbol
glows when the water volume is displayed.
The up button increases the temperature setting.
The down button decreases the temperature setting.
(Kitchen controller only) – This feature enables an alarm to sound
when a set volume of water has flowed through the water heater
(refer to notes below).