4.7.5.
Clean out the drilled holes.
4.7.6.
Position the press and align the holes in the base section with the holes in the fl oor.
4.7.7.
Use four concrete anchor bolts or lag bolts for wooden fl oors, (not included), to secure to the fl oor.
WARNING! To prevent serious injury DO NOT use damaged equipment. If abnormal noise or vibration occurs have the problem
corrected.
4.8.
BEFORE FIRST USE
4.8.1.
Before operating the press, purge the hydraulic system in order to eliminate any air that may have built up during transit. Open the
release valve and pump the handle several times and close the release valve. Should the system malfunction at any time, repeating
this process may resolve the problem.
DANGER! Models are purpose designed to withstand greater loads than the hydraulic units can develop. For safety reasons, always
ensure the workpiece and press tools are secured on the table and will not fl ex or suddenly "give way" causing danger to operator or
the component. Also ensure you have read and understood section 1 Safety Instructions.
5. OPERATION
5.8.1.
Check that release valve, located on the front face of the protective housing for pump (#52), on the hydraulic unit is fully closed, ready for
operating. .
5.8.2.
Position the table at the required operating height by inserting the pins into the appropriate holes in the frame.
5.8.3.
Position the V-block plates or press tools to be used onto the table and align beneath the ram. Place workpiece onto the table or V-blocks
and align beneath the ram as required.
NOTE: Care must be taken to ensure a V-block does not fall from the press table. If necessary hold the configuration in position with
clamps (not supplied).
WARNING! DO NOT apply off centre loads.
5.8.4.
Rotate the speed control valve clockwise, located on the right hand side of the protective housing for pump (#52), to the 'Quick Without
Load' position to lower the ram head rapidly until the ram is close or just touching the workpiece by using either the handle or foot pedal.
NOTE: If the foot pedal is selected for use, remove the handle from the pump assembly.
5.8.5.
When the ram head has made contact with the workpiece, rotate the speed control valve anti-clockwise to the 'Slow With Load'
position, providing a more controlled pressing with full load capacity.
NOTE: The 'Quick Without Load' setting will only operate at approximately 5tonne.
WARNING! Monitor the pressure gauge during operation to ensure that the rated capacity of the press is not exceeded.
5.8.6.
When the operation is complete turn the release valve anti-clockwise to release the pressure. The piston and the ram head will
retract automatically.
NOTE: Always keep the piston retracted after use to avoid corrosion.
6.
MAINTENANCEI
7M
NOTE: Maintenance and repair must be carried out by qualified person. Contact your Sealey stockist for details.
6.1.
Check all fittings are tight before each use.
6.2.
Lubricate all moving parts at regular intervals.
6.3.
Always keep the press clean, dry, and protect from harsh conditions.
6.4.
Should you need to replace the oil ensure the piston is fully retracted. An excess of oil will render the press inoperative.
Use only appropriate Sealey hydraulic jack oil. DO NOT use brake fluid. Contact your local Sealey stockist for details. Purge the system
to remove any air.
6.5.
Check your model parts information for spares.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE MACHINE.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.
DO NOT RETURN PRODUCT TO US. Please telephone us on 01284 757500 to obtain the address and phone number of your local
agent.
If the product is under guarantee please contact your stockist.
De-commissioning Product
Should the product become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of
the product and the oil according to local regulations.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our
technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
NTENANCE
01284 703534
Original Language Version
sales@sealey.co.uk
www.sealey.co.uk
YK30FFP.V2 Issue 1 10/05/21

Advertisement

loading