6. ENVIRONMENT
Operating Temperature: 0~35°C (Ambient)
Operating Humidity: 10%~90% (Non-condensing)
Operating Altitude: 0 - 14,000 feet (Non-Operating)
7. Dimensions (Physical dimension)
Height
Width
Depth
8. Weight (Physical weight)
a. Net:
23.0± 1kg (without Base)
25.0± 1kg (with Base)
b. Gross:
32± 1kg
9. Precautions
Please pay attention to the followings when you use this TFT LCD module.
9-1. Mounting Precautions
(1) You must mount a module using holes arranged in four corners four sides.
(2) You should consider the mounting structure so that uneven force (ex. Twisted
stress) is not applied to the module. And the case on which a module is
mounted should have sufficient strength so that external force is not
transmitted directly to the module.
(3) Please attach the surface transparent protective plate to the surface in order to
protect the polarizer. Transparent protective plate should have sufficient
strength in order to the resist external force.
(4) You should adopt radiation structure to satisfy the temperature specification.
(5) Acetic acid type and chlorine type materials for the cover case are not
desirable because the former generates corrosive gas of attacking the
polarizer at high temperature and the latter cause circuit broken by
electro-chemical reaction.
(6) Do not touch, push or rub the exposed polarity with glass, tweezers or
anything harder than HB pencil lead. And please do not rub with dust clothes
with chemical treatment. Do not touch the surface of polarizer for bare hand or
greasy cloth.(Some cosmetics are detrimental to the polarizer.)
CONFIDENTIAL – DO NOT COPY
Display Module
848.6
1458.6
69.9
Display Module + Base
890.5
1458.6
348.7
(Unit: mm)