This remote control also displays when the filter(s) needs to be replaced/ cleaned or when the ventilation system is malfunctioning. Brink supplies a range of wireless remote controls/sensors that make contact with a heat recovery unit by means of a USB transceiver. This range consists of the 5 following types of...
Page 4
The connected ventilation unit is operated by pressing one of the buttons on the Wireless Controller with humidity sensor with your finger. For explanation of the buttons of the Wireless Controller with humidity sensor see ® Overview operational controls page 7. The Wireless Controller with humidity sensor must always be used with a transceiver on the HRU appliance;...
1. Wireless Controller with humidity sensor 2. Frame 3. Wall bracket 4. Double-sided adhesive tape 5. Mounting screws 6. USB transceiver 7. Short information with QR- code to on line manual Wireless Controller with humidity sensor 616880-B Brink / 5...
2 Technical specification 2.1 General product specification Product description Name: Wireless Controller with humidity sensor Technical product specifications Operating voltage: Protection class: IP21 CR2032.MRF Lithium (preferred manufacturer Renata or Panasonic CR-2032/BS ) Type of battery : Not applicable if a permanent power connection is used! Frequency 868 MHz...
"button press" confirmation. Filter/ fault LED This LED indicates when filter (s) must be cleaned / replaced or when a malfunction has occurred in the connected HRU appliance. Wireless Controller with humidity sensor 616880-B Brink / 7...
Page 8
Filter notification The filter(s) in the HRU appliance, connected to the Wireless Controller with humidity sensor, should be cleaned or replaced when the red LED on the Wireless Controller with humidity sensor appears. This LED is on for 10 seconds every 3 hours or for 300 seconds if any of the buttons are operated (Wireless Controller with humidity sensor with battery power supply).
Click the Wireless Controller with humidity sensor (A) together with supplied frame (B) on the wall bracket (C). After mounting the Wireless Controller with humidity sensor on the wall bracket remove the foil from the front. Wireless Controller with humidity sensor 616880-B Brink / 9...
Step 4 When the Wireless Controller with humidity sensor has been fitted on the wall the USB transceiver can be placed in the USB port of the appliance which must be connected with the Wireless Controller with humidity sensor. To connect the USB transceiver with HRU appliance see ®...
Page 11
Controller with humidity sensor. To connect the USB transceiver with HRU appliance see ® Connecting with USB Tranceiver (Pairing) page 13, Connecting additional RF sensor with USB Tranceiver (Pairing) page 16 . Wireless Controller with humidity sensor 616880-B Brink / 11...
A. Gira - System 55 B. Busch Jaeger Reflex S1 C. Jung AS D. Siemens Delta E. Berker S.1 F. Merten System M The above mentioned alternative frames are not included in the Brink delivery program! Wireless Controller with humidity sensor 616880-B...
Pairing enabled when the LEDs(4 pcs) light in turn (0.5 sec. ON and next will ON when previous is OFF). Pairing disabled when Filter/service LED is ON for two seconds; go back to step 3. Wireless Controller with humidity sensor 616880-B Brink / 13...
Page 14
Step 5 For configure a "note ID" button 1 on the RF Controller with RH sensor . For example press button 1; LED 1 will flash once. When there are more RF Controllers or RH sensors to connect with the device, press different button;...
▪ Press the button for more than 20 seconds. ▪ ▪ To confirm this reset the green LED will flash two times. ▪ ▪ All the pairing information has been deleted from the ▪ USB transceiver. Wireless Controller with humidity sensor 616880-B Brink / 15...
5 Information additional Wireless Controller with humidity sensor 5.1 Connecting additional RF sensor with USB Tranceiver (Pairing) For connecting another Wireless Controller with humidity sensor or only an RF humidity sensor follow the steps as described below: Step 1 Apply main power supply to the HRU appliance. Step 2 Press the pairing button of the USB transceiver (>2 sec &...
+2 = most sensitive Sensitivity 0 = default setting -2 = least sensitive Check the operation of RH sensor Select step number 9 in readout menu (See the installation instructions). ------------------------------------------------------------------------------------------------------------------------------- Wireless Controller with humidity sensor 616880-B Brink / 17...
Page 18
Sky Excellent After installing one or more RH sensors it must be activated in the settings menu step number 29 to ON. Optionally, the sensitivity of the sensor can be altered by means of step number 30. Process for adjusting the value (s) in the settings menu of the Renovent Sky, see the installation instructions.
For replacing battery take Wireless Controller with humidity sensor from the wall bracket (see ® Remove Wireless Controller with humidity sensor from wall bracket page 10). Wireless Controller with humidity sensor 616880-B Brink / 19...
7 Environment Take note! The Wireless Controller with humidity sensor may not be removed as unsorted urban waste, but should be treated separately. Make enquiries within your own region, where the Wireless Controller with humidity sensor can be handed in when use has been terminated. Do not throw away electrical devices or parts, but check if (parts of) the Wireless Controller with humidity sensor cannot be handed in, recycled or re-used.
The Wireless Controller with humidity sensor operation is guaranteed for a period of two years from the time of delivery. This guarantee is granted in accordance with Brink Climate Systems B.V. General Terms and Conditions.
9 Conformity declaration Manufacturer: Brink Climate Systems B.V. P.O. Box 11 Address: NL-7950 AA, Staphorst, The Netherlands Product: Wireless Controller with humidity sensor The product described above complies with the following directives: ¨ 2014/35/EU (low voltage directive) ¨ 2014/30/EU (EMC directive) ¨...
Need help?
Do you have a question about the Air for life and is the answer not in the manual?
Questions and answers