PicC Electronics SMS Alert 9 User Manual

PicC Electronics SMS Alert 9 User Manual

Advertisement

Quick Links

The range

SMS Alert 9 is developed to connect to an existing alarm system or equipment to be monitored and controlled. It
is a 9
input,
and 3 switched relay output unit that keeps you in constant contact with your home or business. It
notifies you instantly when the inputs are triggered by sending an SMS or missed call to four cellphones. You
can phone the unit and listen in for possible intruders. As it is bi-directional, you can also send the unit SMS
messages and control remote systems. SMS Alert 9 can be configured as a two-way intercom system using a
Base Station intercom. The input strings and phone numbers of the users are programmable by the
user.
Examples: AC Loss/Restore, motion detection; temperature monitoring; computer server room control; 3-phase
imbalance; over/under voltage monitoring; field monitoring by using solar energy; opening of electric gates;
steamer room control & monitoring; farm water pump control and monitoring; air conditioning monitoring and
control; access control and monitoring, etc.
SMS Alert 1 works on the same principle than SMS Alert 9, but it is smaller and less expensive. It is a
programmable dual single
155mm x 75mm x 55mm. It reports to four cellphones.
Input 1: (Dual option)
Can be set to send a SMS on both a Negative apply or Negative remove trigger. The SMS that will be send is
Programmable.
Examples:
Open your car with your cell phone when you accidentally locked your key in your car; receive a
SMS when your car alarm is on; activate pepper gas in your car; switch boiler rooms on, etc.
SMS Alert Alarm / Plus is a lockup-and-go alarm and does not require an existing alarm system. It is a 9 input,
1 switched relay
output,
SMS, remote control or key switch. It reports to four cellphones.
This is an upgraded SMS Alert 9 that connects to a BPT intercom system. This system enables your visitors to
call and talk to you from your intercom by pressing a button, where after you can open your gate via SMS. The
user can change the phone number as required. It reports to four cellphones.
SMS Alert 9
SMS Alert 1
input,
and 1 switched relay output device. The dimensions are approximately
SMS Alert 9 Alarm /Plus
LED and Siren output device. You can arm or disarm your SMS Alert Alarm via
SMS Alert 9 Intercom
Page 1 of 1
SMS Alert Alarm / Plus

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMS Alert 9 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PicC Electronics SMS Alert 9

  • Page 1 & monitoring; farm water pump control and monitoring; air conditioning monitoring and control; access control and monitoring, etc. SMS Alert 1 SMS Alert 1 works on the same principle than SMS Alert 9, but it is smaller and less expensive. It is a programmable dual single input, and 1 switched relay output device.
  • Page 2 SMS Alert Alarm / Plus SMS ALERT ALARM / PLUS User Manual SMS Alert Version 7.7 Input 1 : ZONE 1 Input 2 : ZONE 2 Input 3 : ZONE 3 Input 4 : ZONE 4 Input 5 : ZONE 5 Input 6 : ZONE 6 Input 7 : ZONE 7 Input 8 : ZONE 8...
  • Page 3 SMS Alert Alarm / Plus Quick Start Steps 1. SIM card - Insert the SIM card into the phone. Ensure the SIM card is activated. Test this by sending a SMS and making a missed call manually from the SMS Alert cellphone to your phone. 2.
  • Page 4 SMS Alert Alarm / Plus How to program the SMS Alert to report to a 2 or 4 cellphone cellphone, send 1234 and then the character c from a second If you want the SMS Alert to report to a 2 cellphone to the SMS Alert.
  • Page 5 SMS Alert Alarm / Plus How to operate the microphone to silently listen in You are able to phone the SMS Alert and listen in for noises within a 20m radius. Phone the SMS Alert and wait for it to auto answer. It will auto answer automatically after two rings. Siren If B is enabled (yellow LED on) and the unit is armed, the siren output relay will trigger for 1 minute and then reset.
  • Page 6 SMS Alert Alarm / Plus function can be switched (toggled) on and off by sending: 1234 01 (this is off by default). Example : 1234 01. There must be a space between 1234 and 01. You will get the following SMS back: x?xx The return string format is [SMS for arm input | Missed Call | Relay switch for arm input | Input swap] 10 SMS function on/off...
  • Page 7 SMS Alert Alarm / Plus SMS characters SMS Alert accepts all characters if they are all upper or lower case. E.g. 1234 A ON or 1234 a on. Microphone The microphone is mounted on the side of the box .The range is dependent on the environment in which it is installed in.
  • Page 8 If they are unable to help you, we will be more than happy to assist. Disclaimer: PicC Electronics will not be held responsible for loss, damage or injury to any persons, company or legal entity using SMS Alert. It is also recommended that the SMS Alert is tested on a regular basis, for example by sending a status request to it.

This manual is also suitable for:

Sms alert 1Sms alert 9 plus

Table of Contents