Section 2, Installation; Figure 2-1- Preferred Lifting Method - Gardner Denver INTEGRA EFA99F Operating And Service Manual

Base-mounted compressors
Table of Contents

Advertisement

SECTION 2
INSTALLATION
GENERAL - On receipt of the unit, check for any damage that may have been incurred during transit.
Report any damage or missing parts as soon as possible.
Do not electric weld on the compressor or base; bearings can be damaged by
passing of current.
LIFTING UNIT (Figure 2-1, page 14) - Proper lifting and/or transporting methods must be used to prevent
damage.
Lift compressor unit by base only. Do not use other places such as motor,
compressor or discharge manifold piping as lifting points.
The eyebolts or lugs provided on the motor are for lifting the motor only and
should not be used to lift any additional weight. All eyebolts must be securely
tightened. When lifting the motor the lifting angle must not exceed 15 degrees.
Failure to observe this warning may result in damage to equipment or personal
injury.
CAUTION
CAUTION
DANGER

Figure 2-1- PREFERRED LIFTING METHOD

13-8-639
Page14