This Cavius carbon monoxide (CO) alarm is de-
signed and tested to detect CO in private homes,
camping trailers, mobile homes and caravans. It
will provide early warning of the presence of CO.
SAFETY INSTRUCTIONS:
The device comes with a 3V lithium battery. Bat-
teries are to be handled with care and battery pow-
ered devices should be kept out of reach of chil-
dren. Do not try to recharge or burn the batteries.
Information about carbon monoxide:
CO - Carbon monoxide - is known as the "silent
killer" because it is odourless, tasteless and co-
lourless. It can kill in few minutes. This apparatus
may not prevent the chronic effects of Carbon
Monoxide exposure.
All people are at risk for CO poisoning. Unborn ba-
bies, infants, the elderly, and people with chron-
ic heart disease, anemia, or respiratory problems
are generally more at risk than others.
The apparatus will not fully safeguard individuals
at special risks
Breathing CO can cause headache, dizziness,
vomiting, and nausea. If CO levels are high
enough, you may become unconscious or die.
1. TECHNICAL INFORMATION:
Diameter: 40mm Height: 38m.
Type of alarm: Type B apparatus with elec-
tro-chemical CO sensor.
Battery: Powered by a non-replaceable 3V
CR123 Lith ium battery with 10-year life (included).
IMPORTANT: Do not try to replace the bat-
tery. Replace the product if the battery fails.
Product Life: 10 years after manufacturing date.
Complies to standards: EN50291-1:2018,
EN50270, EN50271, EN60335, RoHs, REACH.
Working condition: -10 to +40
C, 30 to 95% non-con-
0
densing.
Storage/Transport: -20 to +50
C, 10 to 95% non-
0
condensing.
Alarm Sound Level: The minimum sound level is 85
dB at 3 meters.
2. THE BEST AREAS TO INSTALL YOUR CO
ALARM:
• Ideally, an apparatus should be installed in every
room containing a fuel-burning appliance.
UK
Mounting
base
Red LED
Alarm indicator
Test/ hush
button
• Near bedrooms and living areas.
• On each level of your home.
• 1 to 3 meter away from all fuel burning applianc-
es.
• At eye level to allow optimum monitoring of the
indicator lights.
Recommended CO alarm location
2. AREAS WHERE NOT TO INSTALL
CO ALARMS:
• In an enclosed space (for example in a cup-
board or behind a curtain).
• Where it can be obstructed (for example by fur-
niture).
• Directly above a sink.
• Next to a door or window.
• Next to an extractor fan.
• Next to an air vent or other similar ventilation
openings.
• In an area where the temperature may drop below
-10 °C or exceed 40 °C.
Ceiling
Wall
Minimum 15cm from ceiling
Minimum 1,20m to 1,50m from the floor
Floor
Green LED
Power indicator
Sounder
Yellow LED
Fault indicator
Wall
1 to 3m from fireplace
• Where dirt and dust may block the sensor.
• In a damp or humid location.
• In the immediate vicinity of a cooking appliance.
4. PLACEMENT:
The CO alarm is designed to be installed on the
wall or a ceiling.
5. INSTALLING YOUR CO ALARM:
CAUTION: This alarm should be installed by
a competent person.
The installation of this device should not be
used as a substitute for proper installation,
use and maintenance of fuel burning appli-
ances, including appropriate ventilation and
exhaust systems.
It does not replace a smoke alarm.
Installation with screw and plug:
Detach the alarm from the mounting base by twisting
counter clockwise.
Use the mounting base to mark up horizontally
the screw holes on the wall.
Mark up screw holes with a pen
Attach the alarm by twisting clockwise.
Please note: The label in the product must not
be removed as it contains important information
regarding the product.
Ceiling
Wall
Minimum 30cm
from wall
Peak ceiling
Use the enclosed screws
and plugs for installation