Application; Specification And Parameter; Limit Parameter; Operating Parameter - Ebyte E22-400T22DC User Manual

Sx1262 433/470mhz 160mw lora wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Manual
The size and shape are consistent with our E32 series modules, which can be directly replaced to improve product
performance and distance.

1.3 Application

Home security alarm and remote keyless entry;
Smart home and industrial sensors;
Wireless alarm security system;
Building automation solutions;
Wireless industrial-grade remote control;
Health care products;
Advanced Meter Reading Architecture(AMI);
Automotive industry applications.

2. Specification and parameter

2.1 Limit parameter

Main parameter
Power supply(V)
Blocking power(dBm)
Operating temperature(℃)

2.2 Operating parameter

Main parameter
Operating voltage(V)
Communication level(V)
Operating temperature(℃)
Operating frequency(MHz)
TX current(mA)
Power
RX current(mA)
consu
mption
Sleep current(μA)
Max Tx power(dBm)
Receiving sensitivity(dBm)
Air data rate(bps)
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
Performance
Min.
Max.
0
5.5
-
10
-40
+85
Performance
Min.
Typ.
2.3
5.0
-
3.3
-40
-
410.125
433.125
493.125
-
110
-
12
-
2
21.5
22.0
-146
-147
0.3k
2.4k
62.5k
Voltage over 5.5V will cause permanent damage to
module
Chances of burn is slim when modules are used in
short distance
Industrial grade
Max.
5.5
≥5.0 V ensures output power
-
For 5V TTL, It is recommended to add level conversion
85
Industrial design
Support ISM band
-
Instant power consumption
-
-
-
Software is shut down
22.5
-
-148
Air data rate is 0.3 kbps
Controlled via user's programming
E22-400T22DC User
Remark
Remark
2-5