6.5 Deep sleep mode(Mode 3)
M0 = 1,M1 = 1
Type
Transmitting
Unable to transmit wireless data
Receiving
Unable to receive wireless data
When from the sleep mode to other modes, the module will reconfigure the parameters. During the configuration process,
Note
AUX will remain low; After configuration,it outputs high level, we suggest that user test rising edge AUX.

7. Register read and write control

7.1 Command format

In configuration mode (mode 2: M1 = 1, M0 = 0), the list of supported commands are as follows (only 9600, 8N1
format is supported when):
No.
Command format
1
Set register
2
Read register
Set
temporary
3
registers
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
Command: C0+starting address+length+parameters
Response: C1+starting address+length+parameters
E.g 1: Channel is 0x09
command starting address length parameter
Send:
C0
05
Return: C1
05
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air
data rate (1.2K).
Send: C0 00 04 12 34 00 61
Return: C1 00 04 12 34 00 61
Command: C1+starting address+length
Response: C1+starting address+length+parameters
E.g 1:Read channel
command starting address length parameter
Send:
C1
05
Return: C1
05
E.g 2: Read module address, network address, serial port and air data rate.
Send: C1 00 04
Return: C1 00 04 12 34 00 61
Command: C2+starting address+length+parameters
Response: C1+starting address+length+parameters
E.g 1: Channel is 0x09
command starting address length parameter
Send:
C2
05
Return: C1
05
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air
data rate (1.2K).
Description
01
09
01
09
01
01
09
01
09
01
09