7.2 Register description

Read or
Address
Name
write
Read/W
00H
ADDH
rite
Read/W
01H
ADDL
rite
Read/W
02H
NETID
rite
Read/W
03H
REG0
rite
Read/W
04H
REG1
rite
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Description
ADDH(default 0)
ADDL(default 0)
NETID(default 0)
7,6,5
UART: Serial port rate(bps)
000: 1200
001: 2400
010: 4800
011: 9600(default)
100: 19200
101: 38400
110: 57600
111: 115200
---------------------------------------
4,3:
Serial parity bit
00:8N1(default)
01:8O1
10:8E1
11:8N1(equal to 00)
-----------------------------------
2,1,0,air data rate
000: 0.3k
001: 1.2k
010: 2.4k(default)
011: 4.8k
100: 9.6k
101: 19.2k
110: 38.4k
111: 62.5k
7,6:
Sub packet setting
00: 240 bytes(default)
01: 128 bytes
10: 64 bytes
11: 32 bytes
--------------------------------------
5 :RSSI Ambient noise enable
1: Enable
0: Disable(default)
--------------------------------------
4,3,2 Reserve
--------------------------------------
1,0:
Transmitting power
E22-400T30S1C User manual
Remark
The module address is high byte and low byte.
Note: When the module address is FFFF, it can be
used as the broadcast and monitor address, that
is the module will not perform address filtering.
Network address, used to distinguish the network.
When communicating with each other, they
should be set to the same.
For the two modules that communicate with each
other, the serial port baud rate can be different,
and the verification method can also be different.
When transmitting large packets continuously,
users need to consider the data blocking caused
by the same baud rate, and data may even be
lost. It is generally recommended that both
parties have the same baud rate.
---------------------------------------
Both parties must be the same
The higher the rate, the shorter the distance
When the data is smaller than the sub packet
length, the serial output of the receiving end is an
uninterrupted continuous output.
When the data is larger than the sub packet
length, the receiving end serial port will output
the sub packet.
--------------------------------------------
When enabled, the C0 C1 C2 C3 command can be
sent in the transmitting mode or WOR
17