Step 1: Selection of measurement point & pipe preparation
Avoid installation of sensors in the vicinity of deformations and
pipe defects, near welding seams or where deposits could have
accumulated.
Select a measuring point with sufficient straight pipe to obtain
accurate measurements. Please consult the manual for the
recommended distances from sources of disturbance.
For a horizontal pipe, mount the sensors on the side of the
pipe. For a vertical pipe, mount the sensors at a location where
the liquid flows upwards. (Pic 1)
Mount the sensors in the direction of the flow. (Pic 2)
Clean the pipe at the measurement point. Remove loose paint
and rust with a wire brush or file.
Apply coupling paste to the face of the clamp-on sensors before
attaching them to the pipe.
Pic 1: Mounting points
Step 2: Keyboard familiarisation
Step 3: Quick Start menu and Setup Wizard
The flow meter can be prepared for measurement with the Setup
Wizard as found in the Quick start menu.
Subject to change without prior notice. I Copyright © Katronic Technologies Ltd. 2011 I Issue: KF150QuickStartV30E0711
KATflow 150 Quick Start Manual
Flow in pipe
Pic 2: Flow direction
Show NEXT (1) available item
Q
(2) = Start totalizer function
ON
Show next DISPlay (3)
Q
(8) = Stop totalizer function
OFF
DIRECT (9) access to trend plot
Move menu / selection item UP
Move menu / selection item DOWN
ESCape entry without saving
Switch device OFF (press > 2 sec.)
ENTER selection with saving
Upon first power on and the boot
up sequence, the Main Menu is
displayed.
Use the UP and DOWN cursor
keys to select Quick start and
confirm by pressing ENTER.
1 / 3
Select Setup Wizard CH1 to set
up measurement channel 1, or
CH2 for channel 2. Confirm
selection by pressing ENTER. If
the sensors are recognised, the
serial number will be shown. If
not, they can be selected.
Select the main measurement
unit using the cursor keys and
confirm with ENTER. This unit
will be displayed in the middle of
the measurement screen. Selec-
ting OFF deactivates the mea-
surement channel.
Select the pipe material using
the cursor keys and confirm with
ENTER.
Enter the outer pipe diameter
Enter the outer pipe diameter
using the keypad and confirm
using the keypad and confirm
with ENTER. Use UP key as
with ENTER. Use UP key as
backspace to correct for entry
backspace to correct for entry
errors. If "0" is entered and con-
errors. If "0" is entered and con-
firmed, an additional screen
firmed, an additional screen
appears that allows entry of the
appears that allows entry of the
circumference. Press ENTER to
circumference. Press ENTER to
confirm.
confirm.
Enter pipe wall thickness using
the keypad and confirm with
ENTER. Use UP key as a back-
space to correct for entry errors.
Select fluid using cursor keys.
Confirm by pressing ENTER.
Enter the fluid temperature using
the keypad. Confirm by pressing
ENTER.
Use UP key as a backspace to
correct for entry errors.
Select pipe liner material using
cursor keys and confirm by pres-
sing ENTER. If a liner material is
chosen, an additional screen
appears that allows entry of liner
thickness.

Advertisement

loading

Summary of Contents for Katronic KATflow 150

  • Page 1 KATflow 150 Quick Start Manual Katronic Technologies Ltd . I Telephone: +44 (0)1926 882 954 I Email: info@katronic.co.uk I Web: www.katronic.co.uk Select Setup Wizard CH1 to set Step 1: Selection of measurement point & pipe preparation up measurement channel 1, or ●...
  • Page 2 KATflow 150 Quick Start Manual Katronic Technologies Ltd . I Telephone: +44 (0)1926 882 954 I Email: info@katronic.co.uk I Web: www.katronic.co.uk Step 3: Quick Start menu and Setup Wizard (continued) Select number of sound passes (sound paths) using cursor keys.
  • Page 3 KATflow 150 Quick Start Manual Katronic Technologies Ltd . I Telephone: +44 (0)1926 882 954 I Email: info@katronic.co.uk I Web: www.katronic.co.uk Heat quantity measurement (where specified) Temperature and flow measurement The KATflow 150 is capable of measuring heat flow and heat For separate measurement of flow and temperature select a flow quantity.

This manual is also suitable for:

Katflow 170Katflow 230Katflow 200-k1nKatflow 200-k1/4nKatflow 200-k4nKatflow 150-2k4n2 ... Show all