VIKING MODEL VIL900
INLINE FAN
ONLY FOR USE WITH: VWH, VIH, VBCV, VICV, DTWL AND
DTWN 24"W TO 42"W WALL AND ISLAND HOODS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer or
your distributor.
2. Before servicing or cleaning unit, switch power off at ser-
vice panel and lock the service disconnecting means to pre-
vent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and ex-
hausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guidelines and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5
When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
INSTALLER: Leave this Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
3. Please read specification label on product for additional
information and requirements.
4. Unit has an unguarded impeller. Do not use in locations where
the impeller is readily accessible to people or animals.
5. Screen guards must be installed if impeller is within reach
of personnel, and less than 7 feet above the floor.
6. When handling fan wear hand protection and stay
clear of sharp edges.
7. Because this unit has rotating parts, safety should be
exercised during all phases of installation, operation and
maintenance.
8. The motor is permanently lubricated. Do not oil or disas-
semble motor.
9. Electrical circuit, including speed control, (if used), must
be rated 3.5 AMPS minimum.
SPECIFICATIONS
MODEL
VOLTS
VIL900
115
1
AMPS
CFM
DUCT SIZE
3.01
900
10" DIA.

Advertisement

loading

Summary of Contents for Viking VIL900

  • Page 1 VIKING MODEL VIL900 INLINE FAN ONLY FOR USE WITH: VWH, VIH, VBCV, VICV, DTWL AND DTWN 24"W TO 42"W WALL AND ISLAND HOODS READ AND SAVE THESE INSTRUCTIONS WARNING CAUTION 1. For general ventilating use only. Do not use to exhaust TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- hazardous or explosive material and vapors.
  • Page 2 3. Use rigid metal ductwork. 4. Always install ventilation products with an approved wall or roof cap. 5. For a truly quiet kitchen ventilation system add a Viking ���� Inline Duct Silencer part number VSIL10 (sold separate- ly) to the installation. The simple addition of a inline duct...
  • Page 3 CONNECT WIRING TO VIL900 INLINE FAN CONNECT WIRING TO THE ROUGH-IN PLATE 1. The opposite end of this wiring will be connected to the Run 115VAC electrical power cable from the service panel rough-in plate in the next step. and from the inline fan to the rough-in plate part number 2.
  • Page 4 If excess build up is present it should be removed from the If special supports are required in anticipation of earthquakes interior of the fan and from the impeller of the fan. the duct clamps that are supplied with the VIL900 are not intended to meet these requirements. MOTOR LUBRICATION To minimize vibration, leave a 1/4”...