Viking VEDV1200 Installation Manual
Viking VEDV1200 Installation Manual

Viking VEDV1200 Installation Manual

Exterior mounted blower for use with viking model vipr181 and vipr181r 48" downdraft ventilator only

Advertisement

Quick Links

MODEL VEDV1200
EXTERIOR MOUNTED BLOWER
FOR USE WITH VIKING MODEL VIPR181 AND VIPR181R
48" DOWNDRAFT VENTILATOR ONLY.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Soci-
ety for Heating, Refrigeration and Air Conditioning Engi-
neers (ASHRAE), and the local code authorities.
PLAN THE
INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the
length of the duct run and
number of elbows needed
are kept to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
be running through the wall.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL VEDV1200
EXTERIOR BLOWER
10" ROUND
DUCT
TO
DOWNDRAFT
TYPICAL ROOF MOUNTED INSTALLATION
WARNING
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
Blower Dimensions
22 x 30.828 x 12.724

SPECIFICATIONS

MODEL
VOLTS
VEDV1200
120
TO
DOWNDRAFT
TYPICAL WALL MOUNTED INSTALLATION
AMPS
CFM
DUCT SIZE
3.0
1200
10" DIA.
10" ROUND DUCT
MODEL
VEDV1200
EXTERIOR
BLOWER

Advertisement

loading

Summary of Contents for Viking VEDV1200

  • Page 1: Specifications

    MODEL VEDV1200 EXTERIOR MOUNTED BLOWER FOR USE WITH VIKING MODEL VIPR181 AND VIPR181R 48" DOWNDRAFT VENTILATOR ONLY. READ AND SAVE THESE INSTRUCTIONS WARNING WARNING 5. When cutting or drilling into wall, or ceiling, do not TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR damage electrical wiring or other hidden utilities.
  • Page 2 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION WALL INSTALLATIONS ROOF INSTALLATIONS 1. Locate the blower on the rear slope of the roof. Place 1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the opening it in a location to minimize duct run.
  • Page 3 INSTALL THE BLOWER INSTALL THE BLOWER ROOF INSTALLATIONS WALL INSTALLATIONS 1. Remove the cover and screws. 1. Place a large bead of caulk on the back side of the housing all along the outer edges. 2. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.
  • Page 4 Be careful not to bend or otherwise damage blower wheel. NOTE: Use duct tape to make ductwork connections secure and air tight. MOTOR LUBRICATION The motor is permanently lubricated. Do not oil or disassemble motor. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99042941C...