Fault
"E:35 / -10"
flashes.
flashes.
lights up.
50
Cause and troubleshooting
The water pressure is low.
No remedial action possible.
The filter in the water inflow is blocked.
Clean the water inflow filter → Page 48.
The tap is turned off.
Turn on the tap.
The water inlet hose is kinked or jammed.
Ensure that the water inlet hose is not kinked or
jammed.
There is water in the base trough.
Turn off the water tap.
Call the after-sales service.
→ "Customer Service", Page 59
The appliance is leaking.
Turn off the water tap.
Call the after-sales service.
→ "Customer Service", Page 59
The automatic voltage control system detects an un-
authorised voltage under-usage.
No remedial action possible.
Note: If the power supply is stable, the programme
continues to run as normal.
Voltage under-usage may cause extension of a pro-
gramme.
No remedial action possible.
Voltage under-usage may cause extension of a pro-
gramme.
No remedial action possible.
The temperature is too high.
Wait until the temperature has dropped.
→ "Cancelling the programme", Page 40
Water level is too high.
Start the Abpumpen programme.
Laundry is caught in the door.
Open the door again.
1.
Remove any trapped laundry.
2.
Close the door.
3.
Press Start/Nachlegen to start the programme.