1.
DESCRIPTION
The DIN310 and DIN310E are microprocessors based earth leakage relays designed for measure the
low-level current flowing from the live part of the installation to the earth in the absent of the insulation
fault. A zero phase current transformer is connected to the relay and function as the sensor for
sensing the leakage current. All conductors of the circuit to be protected shall go through the ZCT.
For better fault preventive control of the system or equipment to be protected, DIN310E series comes
with a pre-fault alarm contact and a positive safety contact. The pre-fault alarm contact is activated
whenever the leakage current exceed 50% of the sensitivity setting. While the positive safety contact
is activated if the relay is power up and function correctly. The DIN310E series also built-in a digital
input port for remotely reset the relay after leakage fault trip, manual test trip or ZCT connection fault.
Model
Alarm status indicator
Increment button
Decrement button
Reset button
Integral test button
DP2 indicator
DP1 indicator
FUNC display
DATA display
Symbols
I
- Sensitivity setting
n
t
- Time delay setting
Flt 1 - Fault record #1 (Most recent)
Flt 2 - Fault record #2
Flt 3 - Fault record #3 (Oldest)
a
b
c
d
e

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIN310 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mikro DIN310

  • Page 1 DATA display DESCRIPTION The DIN310 and DIN310E are microprocessors based earth leakage relays designed for measure the low-level current flowing from the live part of the installation to the earth in the absent of the insulation fault. A zero phase current transformer is connected to the relay and function as the sensor for sensing the leakage current.
  • Page 2 LIGHT INDICATORS [Trip] [Alarm] [FUNC] [DP1] [DATA] Status display indicator display No auxiliary supply Normal condition, no tripping Leakage current > 50% of the I∆n Leakage current > 85% of the I∆n. Trip time delay running. Relay tripped Scroll through setting Scroll through records [DATA] programming mode “Ct”...
  • Page 3 Step 2: Press [ ] and [ ] buttons simultaneously and hold for 3.5s or the [DATA] show “0”. It will clear the entire fault records database. TECHNICAL DATA AUXILIARY SUPPLY DIN310-230A(6)............. 184~276 VAC DIN310E-230A(6)............184~276 VAC Rated frequency............. 50Hz or 60Hz VA rating................. 3 VA typical SETTING RANGES Sensitivity adjustment.............
  • Page 4 ZCT connection fault............7-segment display and red indicators Trip records..............7-segment display Real-time leakage current..........7-segment display ZERO-PHASE CURRENT TRANSFORMERS To operate with Mikro's ZCT series of current transformers MECHANICAL Mounting................. Standard 35mm DIN rail mounting Approximate weight............0.38kg (excluding ZCT)

This manual is also suitable for:

Din310e

Table of Contents