Installation
1.1
Installing a New Thermostat
For a new installation, select a position about 5 feet (1.5 m) above
the floor, where there is good air circulation. The thermostat must be
installed on an inside wall.
Avoid places where there are:
• air draughts (the top of a staircase, an air outlet,...)
• dead air spots (e.g., behind a door)
• direct sunlight
• chimneys or hidden pipes
1.2
Thermostat Installation
Remove the mounting plate from the thermostat.
Loosen the screw holding the mounting plate to
the thermostat.
Lift the lower part of the plate to remove it from
the thermostat.
Loosen the screw holding the wire cover, and remove it.
Secure the mounting plate to the wall and make the appropriate
connection (refer to section 2).
1.3
Wiring
Refer to the diagram. Connect one wire to either therminal and
the other wire to the other terminal.
Connection to a circulator
of a hot water system or
to a baseboard heater
through a 24-V relay
Connection to the furnace of
a hot water system, or to the
boiler of a hot air system
Put the wire cover back on.
NOTE: If you have a CT240 telephone controller, refer to section 5.1
for hook-up.
TH135-01
1.
Before installing the thermostat on the wall, it must be configured
using the dip switches at the back.
2.1
2.2
Proportional Adaptive Mode
This mode analyses previous cycles in order to define the length of
the upcoming cycle. This mode guarantees optimal regulation of 3
cycles (switch #1 to 20 min.) or 4 cycles (switch #1 to 15 min.) per
hour, regardless of the season.
Ideal for:
• Central heating (gas, oil or electric)
• Radiant or convection electrical heating system
• Circulator control in a hot water system
Conventional Mode with Anticipation
Relay
240 V
This mode turns the system On or Off when the temperature reaches
preset levels. This mode is compatible with all heating systems. It is
Transformer
recommended for a multi-zone system or when a thermostat directly
24 VAC
controls a furnace equipped with a combustion gas purge cycle of
more than 30 seconds. The temperature span (deadband) is 0.5°C
(0.9°F).
Relay
Furnace
Installation and User Guide
Thermostat Configuration
15- or 20-minute Cycles
The TH135 can operate on 15- or 20-minute
cycles. While 15-minute cycles provide
greater comfort, the heating system will be
running more often.
Temperature Control Modes
You can choose between two temperature
control modes:
TH135-01
Electronic Thermostat
2.
1/3

Advertisement

loading

Summary of Contents for Aube Technologies TH135-01

  • Page 1 TH135-01 Installation and User Guide Electronic Thermostat   Installation Thermostat Configuration Installing a New Thermostat Before installing the thermostat on the wall, it must be configured using the dip switches at the back. For a new installation, select a position about 5 feet (1.5 m) above the floor, where there is good air circulation.
  • Page 2 After the battery replacement, you have to reprogram the settings (refer to section Even if the thermostat indicates the batteries are good, it is recommended to replace them once a year at the beginning of the heating season. TH135-01...
  • Page 3 This warranty gives you specific legal rights, and you may have other rights which vary from one province, state or region to another.  Customer Assistance If you have any questions on the product installation or operation, contact us at: 1-800-831-2823 aube.service@honeywell.com TH135-01 Printed in USA 33-00052-01 2014-06-01...