5.5.1 Driving with the standard panel
RUN/STOP/RESET key on the standard operation panel is effective regardless of the setting of the driving order method(A002). Thus, the following
operation method (1) to (3) is possible without an option if it is an initial value.
(1)Method to perform driving in RUN/STOP/RESET key and perform frequency setting in Multispeed select
This is the operation method using Run command is given by "RUN/STOP/RESET key"
& Frequency setting is given by Fixed value such as 20/40/60Hz, Accel&Decel time is
10 seconds. If you don't need to change parameters such as Accel&Decel time, the
optional Operator is not required.) To use the set Freq. setting, use the Multi-speed
default frequency setting (1=60Hz),(2=40Hz),(3=20Hz).
■Setup
Function Name
Code
Input [3] function
C003
Input [4] function
C004
The initial value of Acceleration/ Deceleration time is 10sec.
Please change the following parameters as needed.
Function Name
Acceleration time
Deceleration time
※ One of the following is required when changing parameters on NE-S1 series inverters.
① Dedicated operator (NES1-OP) ② Digital operator ③ 5-line LCD operator
④ Modbus ⑤ PC programming tool (ProDriveNext)
(2) Method to perform driving in RUN/STOP/RESET key and perform frequency setting in speed potentiometer
This is the operation method using Run command is given by "RUN/STOP/RESET key" & Frequency setting is given by analog input such as
O-L voltage, Accel&Decel time is 10 seconds. If you don't need to change parameter such as Accel&Decel time, the optional Operator is not required.)
Below diagram is to set the external Freq. setting connecting H-O-L volume to supply O-L voltage.
■Setup
Function Name
Frequency source
The initial value of Acceleration/ Deceleration time is 10sec.
Please change the following parameters as needed.
Function Name
Code
Acceleration time
F002
Deceleration time
F003
※ One of the following is required when changing default parameters on NE-S1 series
inverters.
② Dedicated operator (NES1-OP) ② Digital operator ③ 5-line LCD operator
④ Modbus ⑤ PC programming tool (ProDriveNext)
(3) Method to perform driving in FW/RV teraminal and perform frequency setting in volume resistor
This is the operation method using Run command is given by intelligent input terminal such as FW(RV) function & Frequency setting is given by
analog input such as O-L voltage. If you don't need to change such as Accel&Decel time, optional Operator is not required.) Below diagram is to set
the external Freq. setting connecting H-O-L volume to supply O-L voltage.
■Setup
Function Name
Frequency source
Run command source
Input [1] function
Input [2] function
The initial value of Acceleration/ Deceleration time is 10sec.
Please change the following parameters as needed.
Function Name
Code
Acceleration time
F002
Deceleration time
F003
※ One of the following is required when changing default parameters on NE-S1 series
inverters.
① Dedicated operator (NES1-OP) ② Digital operator ③ 5-line LCD operator
④ Modbus ⑤ PC programming tool (ProDriveNext)
Data
Note
02(CF1)
Default
03(CF2)
Code
Setting Range
F002
0.00 to 3600sec.
F003
0.00 to 3600sec.
Code
Data
A001
01(Control circuit terminals)
Setting Range
0.00 to 3600 sec.
0.00 to 3600 sec.
Code
Data
A001
01(Control circuit terminals)
A002
01(Control circuit terminals)
C001
00(FW)
C002
01(RV)
Setting Range
0.00 to 3600 sec.
0.00 to 3600 sec.
Note
Default:10 sec.
Default:10 sec.
Note
Default
Note
default:10 sec.
default:10 sec.
Note
Default
Default
Default
Note
Default:10 sec.
Default:10 sec.
14
■Control circuit terminals wiring
4
3
L
...
CF2
CF1
■Example of use(default)
Intelligent input
terminal [3]
OFF
60Hz order
ON
40Hz order
ON
20Hz order
■Control circuit terminals wiring
H
O/OI
L
Frequency setting
resistor
Note)
The above is a method to perform analog
input(O/OI) by voltage input. It is necessary for
SW6 on the board to be set for voltage
input(default).
→P9
■Control circuit terminals wiring
H
O/OI
L
2
Frequency setting
RV
resistor
Note)
The above is a method to perform analog
input(O/OI) by voltage input. It is necessary for
SW6 on the board to be set for voltage
input(default).
→P9
PLC
P24
Intelligent input
terminal [4]
ON
OFF
ON
PLC
P24
1
L
PLC
P24
FW

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents