Query Current Module Version: At+Ver; Local Port Operation: At+Clport; Set Up Serial Port:at+Uart; Set Up Dhcp:at+Dhcpc - Hi-Link HLK-RM58S User Manual

Table of Contents

Advertisement

3.1 Query current module version: at+ver

Grammatical rules:
Command type
Grammar
EO
at+ver=?

3.2 Local port operation: at+CLport

Grammar
Command type
at+CLport=8080
EO
at+CLport=?
3.3 Set up serial Port: at+uart
Command Type
Grammar
EO
at+uart=115200,8,n,1
Query Command
at+uart=?
3.4 Set up DHCP: at+dhcpc
Command Type
Grammar
EO
at+dhcpc=1
Query Command
at+dhcpc=?
Return and description
at+ver=HLK-RM58S(V1.00(Nov 30 2017)): current version
Return and description
at+CLport=8080
Ok
Description: set the local port to port 8080
at+CLport=?
8080
Description: Query local port
Return and description
at+uart=115200,8,n,1
Ok
Description: Set up serial Port parameters
at+uart=?
115200,8,n,1
Description:query serial port parameters
Return and description
at+dhcpc=1
ok
at+dhcpc=?
1
Description: 1: dhcp mode, 0: static ip