Download Print this page

Advertisement

Quick Links

INSTRUCTIONS
RALLY
MONTE-CARLO
BLUNIK II PLUS
Blunik II PLUS has 2 available trips, one for each
stage ZR and one global one for the whole
section, which we call Long Link.
ST00 is the only one that can be used in LONG
LINK MODE.
DAILY PROGRAMMING
SYNCHRONIZE THE CLOCK
T i me
CLOCK
T 1 2 00 25
SYNCHRO
ST01
0
8
1 1 00 00
S 1 2 00 1 0
Time to synchronize
SYNCHRO OK ! ! !
0 8 1 1
0
0 00
.
PARAMETERS
Press
to enter the parameters.
Use the keys
&
change the values.
CLOCK SYNCHRO = according to your needs
Mem/ Calibration = according to your needs
M Probe Mode= according to your needs
Blue Led = 0,3 seconds (recommended)
Decal = only for experts
Corrections = 10 m (recommended)
Bl Gr Re Sc Ac = according to your needs
Format = mts
Difference = distance
Language = according to your needs
START KEY = Synchro
Synchro offset
(only for experts)
START in STAGE = disabled
JP GAP = not necessary
M/ Probe TYPE = according to your needs
1
PREPARING SECTION (LONG LINK ST00)
PROGRAMMING ST00 (LONG LINK)
T i me
T i me
T 1 2 00 25
T08 1 0 56
ST01
ST00
S 1 2 00 1 0
Dxx xx xx
Press
to program.
ST00 LL
xx xx xx
00k 0 0 T5h05m00
0
O
f
Select the "Long Link" Mode with the key
ST
00
(
A)
xxx .
xx
228k 130
to
Press
to calculate the average speed.
ST
0
0
(
A)
044 .
87
228k 130
SET THE LONG LINK'S DISTANCE TO ZERO
T i me
T i me
T08 1 0 56
T 1 2 00 25
ST00
ST01
Sxx xx xx
S 1 2 00 1 0
Press
to program.
ST00 LL
xx xx xx
O
00k 0 0 T5h05m00
0
f
ST00 LL
xx xx xx
TR I P 0
=
Select ST00 with keys
Program the total time
for the section.
With the keys
program the final
distance of the section.
END
Press
to exit.
Select ST00 with the
keys
Press
to set the
Long-Link's trip to
000k00
Press
to exit.

Advertisement

loading
Need help?

Need help?

Do you have a question about the II PLUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Blunik II PLUS

  • Page 1 Language = according to your needs 00k 0 0 T5h05m00 Long-Link’s trip to Blunik II PLUS has 2 available trips, one for each START KEY = Synchro 000k00 stage ZR and one global one for the whole Synchro offset...
  • Page 2 T08 1 0 56 time. ST01 ST00 S 1 2 00 1 0 xx xx xx Long-Link. See Offset distance. T00 k 1 0 0 . 0 (Blunik saves Total distance in memory) To go 9 . 2 See countdown.
  • Page 3 It freezes if you press the key The objective of the SPORT DRIVE is to correct the Blunik will add or subtract the difference in distances total 80+48-2=128, that is, you want to increase To not confirm the % multiplying by 1.6 (128/80=1.6)
  • Page 4 01 2 When it flashes you +00k can validate Regularity difference Box distance, validated by pressing ZERO Press Blunik will set the program- T0 1 K 01 2 www.blunik.com med distance as total +00k (It takes 2 seconds for the screen to update)