Marshall Excelsior ME990-3F Installation And Operating Manual

Marshall Excelsior ME990-3F Installation And Operating Manual

3” flanged internal valve

Advertisement

Quick Links

!WARNING!
Failure to follow these instructions or to properly install and
maintain this equipment could result in an explosion and/or
fire causing property damage and personal injury or death.
MEC equipment must be installed, operated, and maintained
in accordance with federal, state, and local codes and
manufacturer's instructions. The installation in most states
must also comply with NFPA No. 58, and ANSI/CGA G-2.1.
For installation in the European Union, the equipment must
also comply with PED/TPED and EN ISO standards. Periodic
inspections, intermediate inspections and exceptional checks
of transportable pressure equipment should be carried out
in accordance with the Annexes of Directive 2008/68/EC and
with 2010/35/EU Directive (TPED) to ensure continued
compliance with their safety requirements.
Only personnel trained in the proper procedures, codes,
standards, and regulations of the LP-Gas industry should
install and service this equipment.
The internal valve must be closed except during product
transfer. A line break downstream of a pump may not
actuate the excess flow valve. If any break occurs in the
system or if the excess flow valve closes, the system should
be shut down immediately.
WARNING:
These products contain a chemical
known to the state of California to cause cancer and
birth defects or other reproductive harm.
Scope of the Manual
This manual covers instructions for the ME990-3F
"Excelerator" Series 3" Flanged internal valves.
Also included in this manual are the instructions for
connection from the valve's operating lever to a cable
control.
Introduction
The ME990-3F internal valve is typically used on the inlets
and outlets of transport truck tanks and large stationary
storage tanks. They can also be installed in-line. Designed
for propane or NH
(Anhydrous Ammonia) at ambient
3
temperatures, the valves can be used on other
compressed gases, but the user should check with the
factory to make sure the valve is suitable for the particular
service and application.
Actuation of the valve can be achieved manually, by cable,
or with a pneumatic actuator.
Marshall Excelsior Company
1506 George Brown Drive Marshall, MI 49068
Phone (269) 789-6700 Fax (269) 781-8340
www.marshallexcelsior.com
The contents of this publication are for informational purposes only. While every effort has been made to ensure accuracy, these contents
are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or for their use
or applicability. Marshall Excelsior Co. reserves the right to modify or improve the designs or specifications of such products at any time
without notice. The MEC™ logo is the trademark of Marshall Excelsior Co.
FORM #1132 ME990-3F IOM
ME990-3F
3" FLANGED INTERNAL VALVE
INSTALLATION AND
OPERATING MANUAL
Specifications
Body Size and End Connection Styles:
Maximum Allowable Inlet Pressure:
Excess Flow Springs:
Temperature Capabilities: -20° to 150°F / -29° to 66°C
Approximate weight: 30 pounds / 14 kg
Body Material: Stainless Steel
DOT Internal Self-Closing Stop Valve Requirement--
U.S. Department of Transportation (DOT) regulations
49CFR§178.337-8(a)(4) require each liquid or vapor
discharge outlet on cargo tanks (except for cargo tanks
used to transport chlorine, carbon dioxide, refrigerated
liquid, and certain cargo tanks certified prior to January 1,
1995) to be fitted with an internal self-closing stop valve.
The ME990 series internal valves comply with the internal
self-closing stop valve requirement under the DOT
regulations.
Specifications
Inlet: NPS 3 / DN 100, CL300 ASME RF Modified Flange
(4.625" / 117mm bore)
Outlet: NPS 3 / DN 100, CL300 ASME Flange
500 psig / 34.5 bar WOG
GPM LPG (vertical down): 175, 250, 300, 375, 400,
475, and 500
l/min LPG: 662, 946, 1136, 1419, 1514, 1798, and 1893
MEC Europe AsP
Alsvej 21
8940 Randers SV
Denmark
Rev C 2/3/21

Advertisement

Table of Contents
loading

Summary of Contents for Marshall Excelsior ME990-3F

  • Page 1 Marshall Excelsior Co. reserves the right to modify or improve the designs or specifications of such products at any time without notice.
  • Page 2 ME990-3F 1” / 25mm MINIMUM FIGURE 2: ME990-3F INSTALLATION SCHEMATIC FORM #1132 ME990-3F IOM Rev C 2/3/21...
  • Page 3: Installation

    !WARNING! After installation check all joints for leaks using a suitable leak detector solution such as Marshall Excelsior low-temp Since there is strong spring force on the operating lever, leak detector before putting the valve into service. avoid getting in the way of lever if it slams to the closed position.
  • Page 4 DOT Passive Shutdown Equipment Requirement-- DOT regulations 49CFR§173.315(n){2) require certain cargo tanks transporting propane, anhydrous ammonia and other liquefied compressed gases to be equipped with passive emergency discharge control equipment that will FORM #1132 ME990-3F IOM Rev C 2/3/21...
  • Page 5: Operation

    FIGURE 4: Operational Schematic Operation Troubleshooting Since the ME990-3F internal valve is most often used on Internal Valve Will Not Open: This could be due to leakage transport trucks, the following procedure applies to that downstream, engaging the pump too soon or from type of application.
  • Page 6: Principle Of Operation

    Continued use without repair can create a on the nameplate. hazardous situation which could result in serious or fatal personal injury or property damage. FORM #1132 ME990-3F IOM Rev C 2/3/21...
  • Page 7 ME990-3F Parts List for ME990-3F ME990-3F- Ref. # Description Qty. Body   Cage Bushing  Stem   Stem O-ring  Spring Seat Excess Flow Spring, Purple, 175 GPM Excess Flow Spring, Black, 250 GPM Excess Flow Spring, Green, 300 GPM...
  • Page 8 ME990-3F FORM #1132 ME990-3F IOM Rev C 2/3/21...