Hitachi RAC-18WPE Service Manual
Hide thumbs Also See for RAC-18WPE:

Advertisement

SERVICE MANUAL
TECHNICAL INFORMATION
FOR SERVICE PERSONNEL ONLY
OUTDOOR UNIT
RAC-18WPE
RAC-25WPE
RAC-35WPE
SPECIFICATIONS
TYPE
MODEL
1 PHASE,50Hz,220-230V
POWER SOURCE
TOTAL INPUT (W
TOTAL AMPERES (A)
COOLING
(KW)
CAPACITY
(B.T.U./h)
TOTAL INPUT (W
TOTAL AMPERES (A)
HEATING
(KW)
CAPACITY
(B.T.U./h)
W
DIMENSIONS
H
(mm)
D
NET WEIGHT
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT
ROOM AIR CONDITIONER
Johnson Controls-Hitachi Air Conditioning Wuhu Co., Ltd.
RAC-42WPE
RAC-50WPE
OUTDOOR UNIT
OUTDOOR UNIT
RAC-18W
PE
RAC-25W
1 PHASE,50Hz,220-230V
419 (250 1,010)
549 (250 1,290)
2.46-2.35
3.08-2.95
2.00 (0.90 2.5)
2.50 (0.90 3.10)
6,820 (3,070 8,530)
8,530 (3,070 10,580)
519 (250 970)
733 (250 1500)
2.93-2.81
3.87-3.71
2.50 (0.90 3.20)
3.40 (0.90 4.40)
8,530 (3,070 10,920)
11,600 (3,070 15,010)
750(+65)
750(+65)
548
548
288(+27.5)
288(+27.5)
32.5
32.5
OUTDOOR UNIT
JCH-WH
REFER TO THE FOUNDATION MANUAL
SPECIFICATIONS ------------------------------------------------------------------- 6
CONSTRUCTION AND DIMENSIONAL DIAGRAM ---------------------- 9
MAIN PARTS COMPONENT --------------------------------------------------- 11
WIRING DIAGRAM ---------------------------------------------------------------- 13
BLOCK DIAGRAM ----------------------------------------------------------------- 16
REFRIGERATING CYCLE DIAGRAM --------------------------------------- 17
DESCRIPTION OF MAIN CIRCUIT OPERATION ----------------------- 20
TROUBLE SHOOTING ------------------------------------------------------------41
PARTS LIST AND DIAGRAM --------------------------------------------------56
DC INVERTER
OUTDOOR UNIT
PE
RAC-35W
PE
1 PHASE,50Hz,220-230V
941 (250 1,460)
4.81-4.60
3.50 (0.90 4.00)
11,940 (3,070 13,650)
1,000 (250 1,700)
5.11-4.89
4.20 (0.90 5.00)
14,330 (3,070 17,060)
750(+65)
548
288(+27.5)
32.5
1
NO.0120E
RAC-18WPE
RAC-25WPE
RAC-35WPE
RAC-42WPE
RAC-50WPE
CONTENTS
OUTDOOR UNIT
OUTDOOR UNIT
RAC-42W
PE
RAC-50W
1 PHASE,50Hz,220-230V
1 PHASE,50Hz,220-230V
1,120 (300 1,700)
1,471 (300 2,100)
5.10-4.88
6.69-6.40
4.20 (1.70 5.00)
5.00 (1.90 5.20)
14,330 (5,800 17,060)
17,060 (6,480 17,740)
1,317 (500 2,100)
1,558 (500 2,750)
5.99-5.73
7.09-6.78
5.40 (1.70 6.00)
6.00 (2.20 7.30)
18,430 (5,800 20,470)
20,470 (7,510 24,910)
792(+85)
792(+85)
600
600
299(+47)
299(+47)
39
39
After installation
PE

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RAC-18WPE

  • Page 1: Table Of Contents

    750(+65) 750(+65) 750(+65) 792(+85) 792(+85) DIMENSIONS (mm) 288(+27.5) 288(+27.5) 288(+27.5) 299(+47) 299(+47) 32.5 32.5 32.5 NET WEIGHT After installation SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT ROOM AIR CONDITIONER OUTDOOR UNIT Johnson Controls-Hitachi Air Conditioning Wuhu Co., Ltd.
  • Page 2 6$)(7< '85,1* 5(3$,5 :25.  ,Q RUGHU WR GLVDVVHPEOH DQG UHSDLU WKH XQLW LQ TXHVWLRQ EH VXUH WR GLVFRQQHFW WKH SRZHU FRUG SOXJ IURP WKH SRZHU RXWOHW EHIRUH VWDUWLQJ WKH ZRUN  ,I LW LV QHFHVVDU\ WR UHSODFH DQ\ SDUWV WKH\ VKRXOG EH UHSODFHG ZLWK UHVSHFWLYH JHQXLQH SDUWV IRU WKH XQLW DQG WKH UHSODFHPHQW PXVW EH HIIHFWHG LQ FRUUHFW PDQQHU DFFRUGLQJ WR WKH LQVWUXFWLRQV LQ WKH 6HUYLFH 0DQXDO RI WKH XQLW ,I WKH FRQWDFWV RI HOHFWULFDO...
  • Page 3 WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS 1. Scope The standards provide for items to be generally observed in carrying and handling semiconductors in relative manufactures during maintenance and handling thereof. (They apply the same to handling of abnormal goods such as rejected goods being returned.) 2.
  • Page 4 (6) Use a three wire type soldering iron including a grounding wire. Metal plate (of Al. stainless steel, etc.) Bare copper wire (for body earth) Working table Resistor 1MΩ(1/2W) Staple Earth wire Fig.3 Grounding of the working table soldering iron Grounding wire Screw stop at the screwed part using a rag plate...
  • Page 5 CAUTION In quiet or stop operation, slight flowing noise of refrigerant in the refrigerating cycle is heard occasionally, but this noise is not abnormal for the operation. When it thunders near by, it is recommend to stop the operation and turn off the circuit breaker for safety. In the event of power failure,the room air conditioner will restare automatically in the previously selected mode once the power is restored.
  • Page 6: Specifications

    SPECIFICATIONS RAC-18/25/35WPE RAC-42/50WPE MODEL FAN MOTOR 47W (DC120~380V) FAN MOTOR CAPACITOR FAN MOTOR PROTECTOR COMPRESSOR GSD088SKQA6JK6 GTD130UKQA8JT6 COMPRESSOR MOTOR CAPACITOR OVERLOAD PROTECTOR YES(INTERNAL) OVERHEAT PROTECTOR FUSE (for MICROPROCESSOR) 15A, 2A, 3A, 3.15A 25A, 2A, 3A, 3.15A POWER RELAY HF161F POWER SWITCH TEMPORARY SWITCH SERVICE SWITCH TRANSFORMER...
  • Page 7 Figure showing the installation of Outdoor unit MODEL RAC-18WPE RAC-25WPE RAC-35WPE The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle. The difference in height between above 200mm the indoor and outdoor unit should be kept below 10m.
  • Page 8 Figure showing the installation of Outdoor unit MODEL RAC-42WPE RAC-50WPE The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle. The difference in height between above 200mm the indoor and outdoor unit should be kept below 10m.
  • Page 9: Construction And Dimensional Diagram

    CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-18/25/35WPE OUTDOORUNIT Handle Handle Air outlet Air Suction grill Rear side Holes for anchor bolt (2 – ø12 x 6 slots for ø8.0 bolt) Notch for anchor bolt (for 2 – ø8.0 bolt) Drain hole Fixing hole Drain hole Service space...
  • Page 10 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-42/50WPE OUTDOORUNIT Unit : mm Drain hole Drain hole Drain hole More than NOTE: 1.For outdoor unit installation , allow at least 2 sides of space around the unit ensure ventilation flue. 2.The connecting pipe , should all the insulated with insulation pipe. 3.Piping length is within 20m.
  • Page 11: Main Parts Component

    MAIN PARTS COMPONENT THERMOSTAT (Room temperature Thermistor) FAN MOTOR Fan Motor Specifications MODEL RAC-18/25/35/42/50WPE WHT(V) CONNECTION RED(U) BLK(W) BLU : BLUE YEL : YELLOW BRN : BROWN WHT : WHITE GRY : GRAY ORN : ORANGE GRN : GREEN RED : RED BLK : BLACK PNK : PINK VIO : VIOLET...
  • Page 12 COMPRESSOR MOTOR Compressor Motor Specifications MODEL RAC-18/25/35WPE RAC-42/50WPE GSD088SKQA6JK6 COMPRESSOR TYPE GTD130UKQA8JT6 POWER SOURCE 220 - 350 V 220 - 350 V OUTPUT 1350W 840W WHITE YELLOW 2M= 2.167 2M= 1.354 RAC-18/25/35WPE RAC-42/50WPE CAUTION When the refrigerating cycle has been operated for a long time with the capillary tubes clogged or crushed or with too little refrigerant, check the color of the refrigerating machine oil inside the compressor.
  • Page 13: Wiring Diagram

    WIRING DIAGRAM RAC-18/25/35WPE RAC-42/50WPE...
  • Page 14 MODEL RAC-18/25/35WPE (AX-16G814)
  • Page 15 MODEL RAC-42/50WPE...
  • Page 16: Block Diagram

    BLOCK DIAGRAM MODEL RAC-18/25/35/4 2/50WPE Power source OUTDOOR UNIT Compressor Power circuit drive circuit Indoor unit Compressor Indoor / Outdoor motor interface circuit Control power circuit Outdoor DC fan motor Reset circuit drive circuit Outdoor Fan motor Overheat thermistor Defrost thermistor Reversing valve drive circuit Outdoor temperature...
  • Page 17: Refrigerating Cycle Diagram

    MODEL RAC-18/25/35WPE COOLING CYCLE OUTDOOR UNIT Silencer Indoor unit Silencer Silencer HEATING CYCLE OUTDOOR UNIT Silencer Indoor unit Silencer Silencer...
  • Page 18 MODEL RAC- 50WP COOLING CYCLE OUTDOOR UNIT 1/2 Silencer Indoor unit Silencer Silencer 1/4 HEATING CYCLE OUTDOOR UNIT 1/2 Silencer Indoor unit Silencer Silencer 1/4...
  • Page 19: Procedure For Disassembly And Reassembly

    Procedure for Disassembly and Reassembly OUTDOOR UNIT MODEL RAC-42/50WP OUTDOOR UNIT MODEL RAC-18/25/35WPE 1. Electrical parts 1. Electrical parts (1)Remove the service value cover lock screws (1)Remove the service value cover lock screws and lower the cover to remove it. and lower the cover to remove it.
  • Page 20: Description Of Main Circuit Operation

    DESCRIPTION OF MAIN CIRCUIT OPERATION RAC-18/25/35WPE 300-330 Main parts C021-C022,37 5 ,420V)
  • Page 21 2. Power circuit (Low voltage) Fig. 2-1 The 230V AC voltage is rectified to DC voltage (B-12V,16V,12V,5V) pass through switching control IC (ICI), switching transformer. (1) B-12V Power supply for electrical expansion valve. (2) 16V Power supply for IPM driver circuit of compressor and fan motor, IGBT action. (3) 12V Power supply for 4 way valve relay, power relay, inrush current relay,motor current amplification, (4) 5V...
  • Page 22 Main parts 001,C002,C003,C004,C005,C011,C013,C014,NF1 1,2,5,8. DC/DC convertor IC (DC12V DC5V). L105 (JUMPER) D110 (EARTH) L104 (JUMPER) 0.5V D110 (EARTH) L103 (JUMPER) 15.5 1.5V D110 (EARTH) 1.0V R120 B-12V Expansion valve B-12V O/P 2.5V R120 B-0V) 1.0V...
  • Page 23 4. Reversing valve (4-way valve) control circuit ・ This model is equipped with a reversing valve ※Voltage measurement timing (4-way Valve). ・ Forced cooling The reversing valve (4-way Valve) "slides" the switch (Test switch) valve in the specified direction for each operating mode and switches the route of Reversing valve refrigerant and holds the route with a built-in...
  • Page 24 HIC P.W.B 70 74 75...
  • Page 25 6. Electric expansion valve circuit...
  • Page 26 2A Fuse DC300 -330V...
  • Page 27 60 100 ( DC300-330V )
  • Page 28 42/50WPE 300-330...
  • Page 29 C021-C023,500 ,450V) 33 ACT R249 IP CUT 300-330...
  • Page 30 2. Power circuit (Low voltage) Fig. 2-1 The 230V AC voltage is rectified to DC voltage (B-12V,16V,12V,5V) pass through switching control IC (ICI), switching transformer. (1) B-12V Power supply for electrical expansion valve. (2) 16V Power supply for IPM driver circuit of compressor and fan motor, IGBT action. (3) 12V Power supply for 4 way valve relay, power relay, inrush current relay,motor current amplification, (4) 5V...
  • Page 31 Main parts 001,C002,C003,C004,C005,C011,C013,C014,NF1 1,2,5,8. DC/DC convertor IC (DC12V DC5V). L105 (JUMPER) D110 (EARTH) L104 (JUMPER) 0.5V D110 (EARTH) L103 (JUMPER) 15.5 1.5V D110 (EARTH) 1.0V R418 B-12V Expansion valve B-12V O/P 2.5V 1 “ - ” 1.0V...
  • Page 32 4. Reversing valve (4-way valve) control circuit ・ This model is equipped with a reversing valve ※Voltage measurement timing (4-way Valve). ・ Forced cooling The reversing valve (4-way Valve) "slides" the switch (Test switch) valve in the specified direction for each operating mode and switches the route of Reversing valve refrigerant and holds the route with a built-in...
  • Page 33 HIC P.W.B 70 74 75...
  • Page 34 6. Electric expansion valve circuit...
  • Page 35 2A Fuse DC300 -330V...
  • Page 36 30 60 ( DC300-330V )
  • Page 37: Service Call Q&A

    SERVICE CALL Q&A Cooling operation The compressor sometimes Cooling when the room Check if the heat stops during cooling. temperature is low may exchanger of the indoor cause the heat exchanger unit is covered with dew. of the indoor unit to gather Wait for 3 to 4 minutes dew.
  • Page 38 Common, etc. In "automatic wind speed" mode, the In wind speed "automatic" mode, This does not abnormal. It indoor fan changes from strong wind the product will sense the heat is because the cold wind to weak wind to slight wind. exchange temperature and, prevention is working.
  • Page 39 Wireless remote control The timer will not become set. Have you set the product to the current time? The timer cannot be set unless it is set to the current time. The current time When set to the current The current time display will disappears 10 seconds time setting, the reading disappear at once.
  • Page 40 This occurs when the room temperature and humidity I set the "sleep" timer during have reached their settings during dehumidification and operation.But the air-conditioner is in a pause. The product will begin the indoor fan will not run (it will again to run within about 3 minutes.
  • Page 41: Trouble Shooting

    TROUBLE SHOOTING MODEL RAC-18/25/35/42/50WPE Inspection instructions RAC-42/50WPE RAC-18/25/35WPE Indoor fan motor Indoor fan motor Power supply Power supply Indoor Electrical Outdoor Electrical Indoor Electrical Outdoor Electrical 1Φ 230V 50Hz 1Φ 230V 50Hz Compressor Compressor motor motor Warning 0V line 0V line Note that the 0 V line of the outdoor electrical parts and Control circuit...
  • Page 42 DISCHARGE, PROCEDURE AND POWER SHUT OFF METHOD FOR POWER CIRCUIT WARNING Caution Voltage of about 350 V is charged between the terminal of smoothing capacitors. During continuity check for each circuit part of the outdoor unit, be sure to discharge the smoothing capacitors.
  • Page 43 Other instructions (1) Detaching and reattaching the receptacles for tab terminal All the receptacles for connecting tab terminals are with a locking mechanism. Forcibly pulling any such receptacle without unlocking it will destroy it. Be on guard. When reconnecting it, insert it securely all the way home. ・Receptacle types and how to unlock them Mild resin cover Cancel button...
  • Page 44 Troubleshooting support Function ・The failure mode detected on the outdoor unit side is displayed by blinking the "LD301". Detecting a failure will stop the outdoor unit [Display on the and keep blinking the LD301 until it is restarted. outdoor unit side] (The communication error will persist until the communication is reestablished.) ・The failure modes detected on the indoor and outdoor unit sides...
  • Page 45 SELF-DIAGNOSIS LIGHTING MODE MODEL RAC-18/25/35WPE...
  • Page 46 SELF-DIAGNOSIS LIGHTING MODE MODEL RAC-42/50WPE...
  • Page 47 After turning on the power, perform air purification by remote control. If there is not the air purifier and operating function,setting to 32 by the remote control,and operate in the cooling mode. Is there 230V AC between Is the LD301 turned on? Ensure the power supply.
  • Page 48 * This page is for RAC-18/25/35WPE Check the blinking frequency of the LD301. The LD301 blinks 13 times. Replace the outdoor electrical parts (in the case of an abnormality in the EEPROM reading error microcomputer or EEPROM). Abnormal The LD301 blinks 9 times. Check the F cable connection (for half insertion, connection by Correct the F cable connection.
  • Page 49 Check the blinking frequency of the LD301. * This page is only for RAC-42/50WPE The LD301 blinks 13 times. Replace the outdoor electrical parts (in the case of an abnormality in the EEPROM reading error microcomputer or EEPROM). Abnormal The LD301 blinks 9 times. Check the F cable connection (for half insertion, connection by Correct the F cable connection.
  • Page 50 The LD301 blinks 10 times. AC 187 V or less, AC 253 V or more Is there AC 220 -230V between Check the power supply. terminal boards L and N? Power supply voltage error AC 187-253 V Ifyon confirm the connect of the reactor Abnormal Is there a voltage of DC 264-358 V ? wire, And it is ok, please change the...
  • Page 51 When cooling: Is the heat exchanger of the outdoor unit clogged up? Is there shelter around? The LD301 blinks 5 times. When heating: Is the heat exchanger or filter of the indoor unit Since the compressor Clear up the causation load was heavy, the clogged up? Overload lower limit cut...
  • Page 52 Abnormal The creepage breaker have already set? The LD301 blinks 14 times Change the compressor and then Does the compressor insulation OK? check the outdoor ele. unit . Active voltage abnormal Normal Change the outdoor ele. unit. Q601,Q602 (RAC-42/50WPE only) have Change the outdoor ele.
  • Page 53 (JUDGING BETWEEN GAS LEAKAGE AND CHECKING THE REFRIGERATING CYCLE COMPRESSOR DEFECTIVE) 1. Troubleshooting procedure (No operation, No heating, No cooling) Lighting mode Blinks Blinks Blinks Blinks Blinks Blinks Connect U,V,W phase leads to the Self- 2 times 3 times 4 times 5 times 6 times 8times...
  • Page 54 How to run the product with the outdoor unit test switch If the indoor electrical parts is out of order and if you wish to run the outdoor unit 1. Turn on the outdoor terminal boards L and N (220-230 V AC). 2.
  • Page 55 Cautions 1. Applying power directly to the outdoor unit will cause a rush current to stress the outdoor unit. Therefore, if the indoor unit is not out of order, do not use the method descried in 2). 2. Before making the connections, be sure to turn off the breaker. 3.
  • Page 56: Parts List And Diagram

    PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL: RAC-18WPE、RAC-25WPE、RAC-35WPE...
  • Page 57 INDOOR UNIT J C H - W H P A R T S N O Q ' T Y / P A R T S N A M E U N I T R A C - 1 8 W P E R A C - 2 5 W P E R A C - 3 5 W P E HWRAC-35WPC...
  • Page 58 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL: RAC-42WPE、RAC-50WPE...
  • Page 59 OUTDOOR UNIT J C H - W H P A R T S N O Q ' T Y / P A R T S N A M E U N I T R A C - 4 2 W P E R A C - 5 0 W P E HWRAC-50WPC A01 BASE...
  • Page 60 RAC-18WPE JCH-WH NO.0120E RAC-25WPE RAC-35WPE RAC-42WPE RAC-50WPE...

This manual is also suitable for:

Rac-25wpeRac-35wpeRac-42wpeRac-50wpe

Table of Contents