U S E R M A N U A L ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D Read and understand all instructions before using this product.
TABLE OF CONTENTS Introduction/Descriptions…………………………………………………………………. Safety Precautions………………………………………………………………………... Warnings and Limitations……………………………………………………………….. Cautions and Limitations………………………………………………………………….. Parts List…………………………………………………………………………………… Air Quality and Volume…………………………………………………………………… Inlet Pressure……………………………………………………………………………… Donning/Doffing Instructions…………..………………………………………………….. Hood Replacement…………………………………………………………………………. Maintenance and Storage…………………………………………………………………… Specifications……………………………………………………………………………….. Warranty and Return Policy………………………………………………………………… NIOSH Approval…………………………………………………………………………….
INTRODUCTION This manual provides instructions for the use and maintenance of the ALLEGRO INDUSTRIES Continuous-Flow Supplied Air Hood Respirator. You must read and understand this manual and be trained in the proper use of the equipment before using it in a contaminated atmosphere.
8. Do not use this respirator during abrasive blasting (including sandblasting). 9. Use only ALLEGRO INDUSTRIES component parts and combinations of parts to assemble or repair this respirator. Consult the parts list and approval label for approved parts. Use of non-approved parts voids the NIOSH approval and may result in bodily injury or death.
CAUTIONS AND LIMITATIONS LOCATED ON THE NIOSH APPROVAL LABEL Not for use in atmospheres immediately dangerous to life or health. Do not exceed maximum use concentrations established by regulatory standards. Airline respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7.1 Grade D or higher quality.
Parts List Item No. Product Number Description 9910-09 Disposable Hood Assy 9911-19 Fully Disposable Hood Assy 9911-19S Fully Disposable Hood Assy, (Saran Coated) 9911-09 Fully Disposable Hood Assy, Dual Bib 9910-01 Breathing Tube Assembly w/Waist belt 9910-11 Breathing Tube Adapter Assy w/Waist belt 9910-02 Head Band Assembly (Standard) 9910-03...
Page 7
(see “Special User Instructions”) Warning ALLEGRO INDUSTRIES air hose is approved for use with this Supplied-Air Hood Respirator. Using any other hose will automatically void the approval of the respirator and may be hazardous to the wearer.
Page 8
HOOD REMOVAL AND REPLACEMENT INSTRUCTIONS FOR P/N’S 9910 & 9910R 1. Exit from the hazardous environment and remove the supplied air hood. 2. Turn off the air supply and disconnect the breathing tube from the air line hose at the waist. 3.
Page 9
1. Exit from the hazardous environment and remove the supplied air hood. 2. Turn off the air supply and disconnect the breathing tube from the air line hose at the waist. 3. Unbuckle and remove the waist belt. 4. Remove the Down Tube Adapter from the Down Tube by unthreading the swivel nut. 5.
Replace lens cover when it becomes difficult to see through the lens. Replace hood when contaminant penetration occurs, or when soiled or damaged. Clean the breathing tubes of the 9910 and 9910R outer surface with mild soap and warm water. Rinse with clean water. Shake to remove excess water and let air dry.
Page 11
In the event that this ALLEGRO INDUSTRIES product is found to be defective in material or workmanship, or not in conformance with any expressed warranty for a specific purpose, ALLEGRO's...