Periodical Cleaning
Machine down for longer than 30 days
For long periods of inactivity, proceed as follows:
• Carry out the operations described in the "Machine down for up to 30 days" section.
Clean the electric compressor unit:
1. Remove the cover by taking out the screws "A."
2. Clean the inside with compressed air (wearing a face mask and safety goggles).
3. Spray the self-cleaning liquid for electrical contacts through the slots on the electric motor.
4. Put the cover back on.
• To ensure dense and lasting formation of foam, replace the sponges, Part No. 520004-747, ("D" in Weekly
Cleaning Diagram) every year.
Pipe Repairs
Maintenance (Continued)
Hose Repairs
If the hoses burst, complete the repair using a section
of hose diameter 6cm (inside) x 8cm (outside), supplied
in the kit.