Advertisement

Quick Links

1100-WD2000
221205

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1100-WD2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bartscher 1100-WD2000

  • Page 1 1100-WD2000 221205...
  • Page 2 Bartscher GmbH Phone: +49 5258 971-0 Franz-Kleine-Str. 28 Fax: +49 5258 971-120 Technical Support Hotline: +49 5258 971-197 D-33154 Salzkotten Germany www.bartscher.com Version: 1.0 Date of preparation: 2020-10-15...
  • Page 3: Table Of Contents

    Original instruction manual Safety ......................2 Explanation of Signal Words ..............2 Safety instructions..................3 Intended Use ................... 5 Unintended Use ..................5 General information ..................6 Liability and Warranty ................6 Copyright Protection ................6 Declaration of Conformity ................ 6 Transport, Packaging and Storage ..............
  • Page 4: Safety

    Safety Diese Bedi enungsanlei tung besc hrei bt di e Installation, Bedi enung und Wartung des Geräts und gilt als wic htige Infor mationsquelle und N achschl agewer k. Di e Kenntnis aller enthaltenen Sic herheits hi nweis e und H andlungs anweisungen schafft die Vorauss etz ung für das sichere und s ac hger echte Ar beiten mit dem Gerät. D arüber hi naus müs sen die für den Ei ns atz ber eic h des Geräts geltenden ör tlichen Unfall verhütungs vorsc hriften und allgemeinen Sicherheits besti mmungen eing ehalten wer den. Dies e Bedi enungs anleitung is t Bes tandteil des Produkts und muss i n unmi ttelbarer N ähe des Ger äts für das In¬s tall ations-, Bedi enungs-, Wartungs- und R einigungspers onal jederzeit z ugänglich auf¬bewahrt werden. Wenn das Ger ät an eine dritte Pers on weiterg egeben wird, muss die Bedi enungsanlei tung mit ausgehändigt wer den.
  • Page 5: Safety Instructions

    Safety WARNING! The signal word WARNING warns against hazards that may lead to moderate or severe injuries or death if the hazards are not avoided. CAUTION! The signal word CAUTION warns against hazards that may lead to light or moderate injuries if the hazards are not avoided. , di e IMPORTANT! The signal word IMPORTANT indicates possible property damages,...
  • Page 6 Safety • Always completely unwind the power cord. • Never place the appliance or other objects on the power cord. • Always take hold of the plug to disconnect the appliance from the power supply. • Check the power cord regularly for damage. Do not use the appliance if the power cord is damaged.
  • Page 7: Intended Use

    Safety Intended Use As described below, every use of the appliance for a purpose differing and/or diverging from its intended standard use, is prohibited and considered to be an unintended use. The following is an intended use: – Venting and exhausting steams and vapours from appliances used for preparing food, –...
  • Page 8: General Information

    General information General information Liability and Warranty All information and instructions in this instruction manual account for legal regulations in force, current level of technical engineering knowledge as well as our expertise and experience, developed over the years. If special models or additional options are ordered, or state-of-the-art technical solutions were implemented, the actual scope of delivery of the appliance may, in some circumstances, differ from descriptions and numerous drawings in this instruction manual.
  • Page 9: Transport, Packaging And Storage

    Transport, Packaging and Storage Transport, Packaging and Storage Delivery Check Immediately upon reception, check the delivery for completeness and possible shipping damage. In the case of visible transport damage refuse to accept the appliance or accept it conditionally. Mark and note the scope of damage in shipping documents/consignment list of the shipping company and lodge a complaint.
  • Page 10: Technical Data

    Technical Data Technical Data Technical Specifications Name: Infusion hood 1100-WD2000 221205 Art. No.: Material: stainless steel Flame protection filters: Typ A Number of filters: Filter material: stainless steel Max. air throughput, in m³/h: 3.700 Degree of protection: IP55 LED Lighting:...
  • Page 11: List Of Components Of The Appliance

    Technical Data – Combined wall and ceiling mounting required • The set includes: fastening material (chains are not part of the delivery) List of Components of the Appliance Fig. 1 1. LED lighting 2. Housing 3. Flame protection filter holder 4.
  • Page 12: Functions Of The Appliance

    Installation and operation Functions of the Appliance Owing to both optional motors, the infusion extractor hood is capable of providing maximum air throughput at the level of 3,700 m³/h, and thus becoming a highly efficient solution also in large kitchens. The combination of fresh air and exhaust air reduces impurities and vapours in a room.
  • Page 13 Installation and operation Unpacking / Mounting • Unpack the appliance, remove all external and internal packaging elements and shipment safeguards. CAUTION! Choking hazard! Prevent children from accessing packaging materials, for instance: plastic bags and EPS elements. • If the appliance is covered with a protective film, remove it. Remove the film slowly, so no glue residues are left.
  • Page 14 Installation and operation The infusion extractor hood is mounted to the wall with a specially enclosed installation brackets. During transportation, they are affixed to the housing of the appliance. Unscrew the installation brackets from the housing. The below figure presents a schematic view of the number and location of brackets. Fig.
  • Page 15 Installation and operation Ceiling Mounting The infusion extractor hood must be additionally fastened to the enclosed eye bolts with four chains or cords (not part of the delivery) and anchored to ceiling (Fig. below). 1. For each fastening holder use M5 bolt, as presented in the figure (detail B). 2.
  • Page 16 Installation and operation Drain Tap Installation To facilitate transportation of the appliance, the drain tap is installed at the internal side of the housing. 1. Undo the drain tap. 2. Screw it to the external side of the housing. Fig. 5 Flame Protection Filters Installation 1.
  • Page 17 Installation and operation Power supply connection • Verify if technical data of the appliance (see rating plate) correspond with the local electric power grid specification. • Connect the appliance to a single, properly grounded mains socket with protective contact. Do not connect the appliance to a multi-socket. •...
  • Page 18 Installation and operation Fan speed regulators and motors are not part of the delivery! 3-0750 Fan Speed Regulator Designed for: – 1100-WD2000 fresh air supply motor – 1100-WD2000 infusion extractor hood Output control: – manual – 4 levels – up to 0.75 kW / 400 V, 50 Hz, 3 NAC...
  • Page 19 Installation and operation 1100-WD2000 Fresh Air Supply Motor Version: Asynchronous motor, 3 phases Number of blower motors: 1 Number exhaust air outputs: 1 Air filter: 1, removable Motor output: 0.75 kW Motor position: beyond the stream of air Output control: with 220121 external fan speed regulator Power supply: 0.75 kW / 400 V 50 Hz...
  • Page 20: Operation

    Installation and operation Operation • Przed pier wsz ym uż yciem wycz yś cić urządz eni e i wypos ażenie zgodni e z e ws kazówkami z awartymi w pu nkcie 6 „Cz yszczen ie” . U waż ać, aby do ins tal acji elektr ycznej i s krz ynki roz dzi elcz ej ni e dostała si ę woda. N astępnie dokł adnie os usz yć urządz eni e i elementy wypos aż enia. •...
  • Page 21: Cleaning And Maintenance

    Cleaning and Maintenance Cleaning and Maintenance Safety Instructions for Cleaning • Before cleaning, disconnect the appliance from the power supply. • Leave the appliance to cool down completely. • Make sure water does not enter the appliance. Do not immerse the appliance in water or other liquids during cleaning.
  • Page 22: Maintenance

    Cleaning and Maintenance Emptying Grease Collection Channel 1. Empty the grease collection channel daily. 2. Open the drain tap and drain entire fat/condensate into a suitable container. 3. Close the drain tap. Maintenance ATTENTION! All maintenance works with the appliance must be performed by qualified personnel only.
  • Page 23: Possible Malfunctions

    Possible Malfunctions Possible Malfunctions Mögliche The table below contains descriptions of possible causes and solutions to malfunctions or errors during operation of the appliance. When malfunction cannot be removed, contact the technical service. Error Possible Cause Solution Appliance is not Appliance is not connected to Connect the appliance venting vapours...
  • Page 24: Disposal

    Disposal Disposal Electrical Appliance Electric appliances are marked with this symbol. Electrical appliances must be disposed of and recycled in a correct and environmentally friendly manner. You must not dispose of electric appliances with household waste. Disconnect the appliance from the power supply and remove power cord from the appliance.

This manual is also suitable for:

221205

Table of Contents