Lincoln Electric INVERTEC V350-PRO Operator's Manual page 21

Hide thumbs Also See for INVERTEC V350-PRO:
Table of Contents

Advertisement

E-2
PROBLEMS
(SYMPTOMS)
Major physical or electrical damage
is evident when the sheet metal
covers are removed.
Input fuses keep blowing, or input
breaker keeps tripping
Machine will not power up (No
lights)
Machine won't weld, can't get any
output.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE AREAS OF
MISADJUSTMENT(S)
1. Contact your local authorized
Lincoln Electric Field Service
facility for technical assistance.
1. Make certain that the fuses or
breakers are properly sized. See
installation section of the manual
for recommended fuse and
breaker sizes.
2. Welding procedure is drawing too
much output current, or duty
cycle is too high. Reduce output
current, duty cycle or both.
3. There is internal damage to the
power source. Contact an autho-
rized Lincoln Electric Service
facility.
1. Make certain that the power
switch is in the "ON" position.
2. The circuit breaker in the recon-
nect area may have opened.
Reset. Check input voltage sec-
tion below.
3. Input voltage selection made
improperly. Power down, check
input voltage reconnect accord-
ing to diagram on reconnect
cover.
4. The 6 amp breaker may have
opened. Check for overload on
42VAC or 24VAC supply from the
14 pin MS-style connector.
1. If the displays show an Err ###
see the fault section for correc-
tive action.
2. If the displays are not lit refer to
machine will not power up sec-
tion.
3. If the thermal symbol is lit refer to
the thermal section.
4. If the output terminals are in
Remote control switch to "ON"
and check for output voltage. If
output voltage is now present
check for correct remote control
connection and operation.
INVERTEC® V350-PRO (CE)
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
CAUTION
RECOMMENDED
COURSE OF ACTION
E-2