Introduction
This pump has been carefully packaged, inspected and tested to ensure safe operation and delivery. Before installing the pump, check to
see if any damage has occurred to the pump from rough handling. Notify the dealer from whom you purchased the pump if any damage
has occurred.
This sewage pump is suitable for pumping sewage, effluent, wastewater, groundwater and other non-explosive, non-corrosive liquids with
up to 2" (51 mm) solids. The pump includes a wide angle float switch that turns the pump on and off as the fluid level rises and falls.
Safety Instructions
The following safety rules should be followed to avoid serious injury or property damage:
Always remove the plug from the electrical outlet before servicing this pump.
1. Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed
with your safety in mind. Be sure to comply with them.
2. We recommend that a separate circuit be led from the home electrical distribution panel and properly protected with a fuse or a
circuit breaker. We also recommend that a ground fault circuit be used. Consult a licensed electrician for all wiring.
3. Do not stand in water when connecting or disconnecting power cord from outlet.
4. This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter.
5. Do not pump flammable liquids with this pump as an explosion or fire could result.
6. Vent sewage or septic tank according to local codes.
7. Do not run this pump dry. Running your pump without water will damage the mechanical seal, reduce the life of the pump and void
the warranty.
8. Do not touch metal motor housing for at least 30 minutes after pump has operated. A severe burn will result if pump is not allowed to
cool. Do not lift the pump by the electrical cord.
9. This product does not require lubrication. A special oil has been put into the motor housing at the factory for lifetime lubrication of the
bearings. Use of any other oil can cause damage and void the warranty.
Installation Instructions
1. Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or gravel surfaces.
2. Install pump in a basin of at least 16 inches (405 mm) diameter and 24 inches (610 mm) depth.
1
#51448EF
8/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Professional Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Duro Professional Series

  • Page 1 Submersible Wastewater Pump Models DSBF300 & DSBW300 Operating & Installation Instructions Introduction This pump has been carefully packaged, inspected and tested to ensure safe operation and delivery. Before installing the pump, check to see if any damage has occurred to the pump from rough handling. Notify the dealer from whom you purchased the pump if any damage has occurred.
  • Page 2: Electrical Information

    Piping for Effluent Applications - 3/4" (19 mm) or less solids ABS, PVC and galvanized steel are suitable piping materials. Check local building codes before making a selection. Piping must be 1½" (32 mm) minimum to carry volume of pipe discharge. If a threaded discharge is required, secure adapter to volute with ABS cement. If a threaded discharge is not necessary, cement pipe directly to volute.
  • Page 3: Cleaning The Pump

    Maintenance Cleaning the Pump . The pump must be kept clean and free of debris. The following steps are for service and cleaning of the pump: . The inlet screen prevents the passage of dirt and other solid material from entering 1.
  • Page 4: Troubleshooting Checklist

    Trouble Shooting Checklist 1. Pump does not run or hums • Pump plug and liquid level control plug not securely fastened together. Push plugs together tightly. • Circuit breaker tripped or fuse blown. Replace fuse (15 amp time delay fuse) or reset breaker. •...
  • Page 5: Directives De Sécurité

    Pompe pour eaux usées submersible Modèles DSBF300 & DSBW300 Directives d'opération et d'installation Introduction Cette pompe a été mise en essai, contrôlée et emballée attentivement pour assurer qu'elle soit livrée en bon état et qu'elle fonctionne proprement. Avant d'installer cette pompe, vérifiez qu'il n'y a eu aucun endommagement causé par une manipulation brusque. Si c'est le cas, faite-le savoir à...
  • Page 6 Tuyauterie pour pompage d'effluent - matières solides de 3/4 po. (19 mm) ou moins La tuyauterie peut être autant faite d'ABS, de PVC ou d'acier galvanisé. Vérifiez les normes locales de construction avant de faire une sélection. La tuyauterie doit avoir au minimum 1½ po. (38 mm) pour supporter le volume du refoulement de la pompe. Si un tuyau à visser est requis pour le refoulement, sécurisez l'adaptateur à...
  • Page 7: Nettoyage De La Pompe

    2. La pompe ne doit jamais fonctionner lorsque la roue de pompe est hors de l'eau. Placez le flottant de sorte qu'il ne peut « s'accrocher » aux rebord du bassin ou à même la pompe. 3. Optional Alarm. Sump pumps can burn out, lose power, become Pour faire un ajustement, augmentez ou diminuez la longueur de la longe du flottant entre un minimum de 4 po.
  • Page 8: Garantie

    Figure 2 - Désassemblage pour le nettoyage d’article Description 302701 Volute de pompe (8097) 302728 Volute de Pompe (8098) 302702 Joint de caoutchouc 302703 Impulseur (8097-78.4 MM) 302704 Impulseur (8098-76.2 MM) — Pomper le crochet 302705 302706 Sceau méchanique — Stator 302707 Sceau...