ITL RLC-200-UNI Installation And Operation Manual

ITL RLC-200-UNI Installation And Operation Manual

Universal led & incandescent a-0 controller

Advertisement

Quick Links

Installation
RLC-0200-UNI
and
Universal
Operation
LED & Incandescent
A-0 Controller
Manual
Toll Free: +1 (866) 624-8309  www.itl-llc.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RLC-200-UNI and is the answer not in the manual?

Questions and answers

Summary of Contents for ITL RLC-200-UNI

  • Page 1 Installation RLC-0200-UNI Universal Operation LED & Incandescent A-0 Controller Manual Toll Free: +1 (866) 624-8309  www.itl-llc.com...
  • Page 2: Front Matter

    ITL, LLC. ITL, LLC and the ITL logo are trademarks of ITL, LLC. All other trademarks and brand names are the property of their respective proprietors.
  • Page 3: Safety Warning

    Do not wear any jewelry. Gold and silver are excellent conductors of electricity.  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 3 of 15...
  • Page 4: Table Of Contents

    Manual Mode Select Switch ..................13 Indicator Lights......................13 Spare Parts & Replacement Parts ................... 14 Technical Support and Contact Info ................15 Contact Info ......................... 15 ..........................15  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 4 of 15...
  • Page 5: Introduction

    Virtually all information necessary for installation and operation of the RLC-200 is available on the “quick info” card located in the door of the enclosure. RLC-200-UNI  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 5 of 15...
  • Page 6: Specifications

    Alarm Relays: 120/230 VAC, 1 Amp PEC: 120/230 Vac, 50/60 Hz, 1 VA 320 Joule, 275V, Input Power, Suppression Side Lights & PEC 23 Joule, 275V, All alarm relays  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 6 of 15...
  • Page 7: Installation

    FAA requirements.  Install cable from RLC-200 to L-810 obstruction lights (markers) per manufacturer’s instructions.  Install Photoelectric Cell and socket (ITL P/N: PEC-1800-120, PEC-SOCK-000).  Install 120Vac line power to the RLC-200 Controller.  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017)
  • Page 8: Rlc-200 Controller Mounting

    RLC-200 RLC-200 Controller Mounting  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 8 of 15...
  • Page 9: Electrical Connections

    Typical connections for a 120VAC system are shown below. It is the responsibility of the installer to comply with all applicable local, state, and federal regulations for installation and operation of this device.  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 9 of 15...
  • Page 10: Connector Descriptions

    Input Power Line Voltage Input Power Neutral Primary Obstruction Lights Power Supply Neutral Secondary (backup) Obstruction Lights Photoelectric Cell Line Power Photoelectric Cell Neutral Photoelectric Cell Signal (120Vac=Night, 0Vac=Day).  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 10 of 15...
  • Page 11: Setup And Operation

    Configuration DIP Switches, the Marker Alarm Setting dial, and the Manual Mode Select Switch. Configuration Configuration Marker Alarm Manual Mode Jumpers DIP Switches Setting Select Switch Alarm Contacts  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 11 of 15...
  • Page 12: Configuration Jumpers

    Note: This manual is subject to change without notice. Refer to the diagram in the door of the RLC-200 or the manual shipped with the RLC-200 for setup and configuration information.  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 12 of 15...
  • Page 13: Marker Alarm Setting

    BCN ALM Not used MKR ALM Indicates a marker alarm. PEC ALM Indicates a photoelectric cell alarm. BU ALM Indicates that the RLC-200 is operating the backup markers.  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 13 of 15...
  • Page 14: Spare Parts & Replacement Parts

    L-810(L) Double Obstruction Light, (LED with Infrared) LMP-116W-120-PHL 116W, 120VAC Marker Lamp LMP-116W-230 116W, 230VAC Marker Lamp LMP-100W-230-AERO 100W, 230VAC Marker Lamp PEC-1800-120 Photo-electric Control, 120VAC, Twilight Level PEC-SOCK-000 Photo-electric Control Socket  Copyright 1999-2017 ITL, LLC DOC-RLC200-MNL Rev8.doc (6/13/2017) Page 14 of 15...
  • Page 15: Technical Support And Contact Info

    Contact Info For information on the RLC-200 controller’s basic functions, refer to this manual. For additional help with the installation or operation of any ITL products, please contact ITL, LLC at one of the following below. Web and Internet Sites Corporate home page: http://www.itl-llc.com...