INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
8
(
Flat head
Battery cover
wood screw
&
Flat head
wood screw
3
Batteries
2
Wireless remote control
The provided Remote Controller is a wireless
type, which also can be used as a wire.
Please see "How to Connect The Remote
Controller for Wired Operation", in case of
wired control is required.
Remark :
• Detail of accessory and installation parts can
see in the accessory sheet.
• Some pictures might be different from the
actual parts.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side
: Ø6.35 mm
Gas side
: Ø9.52 mm
A
(RAS-B10, 13N3KV2 Series
RAS-M07N3KV2 Series)
: Ø12.70 mm
(RAS-B16N3KV2 Series)
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
C
Putty, PVC tapes
5
Filter
8
Flat head
4
Remote control holder
wood screw
Q'ty
One
each
1
One
each
Hook
1
Installation
plate
Shield pipe
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available, provided
by installer)
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with À xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple 9 and cap
water proof ! to the bottom plate of the outdoor unit before installing it.
108 mm
28 mm
Air outlet
600 mm
When using a multi-system outdoor unit is used, refer to the installation
manual provided with the model concerned.
3
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
Rear
right
left
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
125 mm
Air inlet
* Drain nipple and cap
water proof are packed
in outdoor unit.
90 mm
Drain outlet
Left