SecEng SED-902 Manual

Remote & master wireless wiegand / cardax system & i/o
Hide thumbs Also See for SED-902:

Advertisement

Quick Links

SED-902
Remote & Master
Wireless Wiegand / Cardax System
& I/O
Jan 2019
WARNING: PLEASE READ
INSTALLATION INSTRUCTIONS
FIRST
PRODUCT WARRANTY
This product is covered by a 12 month, back to base warranty from date of purchase,
and proof of purchase should be supplied. The warranty does not cover damage that
has resulted in the improper installation or improper use of this product.
The warranty does not cover lightning damage, product misuse, electrical surges or acts of God.
LIMITATION OF LIABILITY
Sec Eng Systems Pty Ltd does not accept any liability for the loss or damage to property
or persons in relation to goods supplied. This disclaimer is only limited to the warranty
of the goods supplied and the intended use.
NOTE: THIS MANUAL IS SUBJECT TO COPYRIGHT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SED-902 and is the answer not in the manual?

Questions and answers

Summary of Contents for SecEng SED-902

  • Page 1 SED-902 Remote & Master Wireless Wiegand / Cardax System & I/O Jan 2019 WARNING: PLEASE READ INSTALLATION INSTRUCTIONS FIRST PRODUCT WARRANTY This product is covered by a 12 month, back to base warranty from date of purchase, and proof of purchase should be supplied. The warranty does not cover damage that has resulted in the improper installation or improper use of this product.
  • Page 2: Please Read First

    3. If installing multiple SED-902 systems in one location, call Sec.Eng Systems for assistance on how to best configure. 4. The SED-902 system supplied is ready to use out of the box - No programming required. Failing to follow the installation instruction may void the...
  • Page 3 INSTALLATION - START HERE INTRODUCTION The SED-902 wireless Wiegand / Cardax system is a combination of 2 devices - SED-902 Master and SED-902 Remote. This allows Wiegand / Cardax card and control information to pass over a 915 MHz low power link...
  • Page 4 INSTALLATION - SED 902 Wiegand Remote SED-902 MASTER Board Layout & Connections Note: The SED-902 has dual markings for MASTER & REMOTE MODE Wiegand POWER COPY PROG TEST RS232 CHARGE @115k in CTx1 LINK readers CRx1 MEMORY xxxx Reader CTx2...
  • Page 5: Dip Switches

    INSTALLATION - SED-902 Wiegand Master SED-902 MASTER Board Layout & Connections Note: The SED-902 has dual markings for MASTER & REMOTE MODE POWER COPY PROG TEST RS232 CHARGE @115k in CTx1 LINK CRx1 OUTPUT XXXX MEMORY CTx2 DATA LEDS CRx2...
  • Page 6 INSTALLATION - SED-902 Cardax Remote SED-902 MASTER Board Layout & Connections Note: The SED-902 has dual markings for MASTER & REMOTE Cardax MODE POWER COPY PROG TEST RS232 CHARGE readers @115k in CTx1 LINK xxxx Reader CRx1 MEMORY blue beep...
  • Page 7 INSTALLATION - SED 902 Wiegand Master SED-902 MASTER Board Layout & Connections Note: The SED-902 has dual markings for MASTER & REMOTE MODE POWER COPY PROG TEST RS232 CHARGE @115k in CTx1 LINK CRx1 Output XXXX MEMORY WHITE CTx2 Data...
  • Page 8: Address Switch

    SED-902 MASTER GUIDE LED’S Power LED = power on Charge LED indicates battery charging (if fitted) Power Link LED indicates that it can see RF link Charging Memory LED indicated SD card fitted CTX1 Link TX = packet being transmitted...
  • Page 9 INSTALLATION - SED-902 Adding Expanders The SED-902 system can support expanders please read Setup 1/ Ensure you set the mode switch on the SED-902 on your expander 2/ Set the address switch according to the number of expanders you have hanging off...
  • Page 10 INSTALLATION - SED-902 Expander Programming The Sed 902 Master & Remote Expanders To enrol a board for self learning 1/ Ensure they are all wired and configured and set up also check dip switches 2/ On the (Master Expander) board the press the Copy & Prog buttons until the signal leds begin to flash.
  • Page 11 SED-902 MASTER GUIDE AC Power in 16V AC 1.5A Battery in 12V Backup battery 7 AH gel cell (do not wire 12V DC into this) RS485 Port (not used for comms) RF Link Relay Relay is active when the Master and Remote units are within range and linked...
  • Page 12 On the SED-902 Remote - the signal light should be ON This means that the link is established and functioning Test an alarm input on the SED-902 Master Relay Board, this should trigger a relay on the SED-902 Remote. Wiring the SED-902 MASTER...
  • Page 13: Technical Specifications

    SED-902 TECHNICAL SPECS TECHNICAL SPECIFICATIONS RADIO SPECIFICATIONS Type Semtech LoRa Frequency Operational 916MHz - 927MHz Transmit Power 100mW Security Encryption By Request Operational Range 500 metres (Line of sight) ACCESS PROTOCOL SUPPORTED Wiegand 240bit (up to) Gallagher/Cardax G BUS (H BUS not supported)
  • Page 14: For Technical Support

    SED-902 TESTING GUIDE NOTE: Both the 915 MHz radio units require line of sight signal, they will work through buildings, however, this may effect signal coverage. Position the Remote at the location where you require to install it and do a field test to...