ECO II AMALGAM SEPARATOR ECO II EXCHANGE OLD TO NEW PureWay Compliance, Inc. 16225 Park Ten Place, Suite 830 Houston, TX 77084 • 877.765.3030 www.PureWay.com...
Page 2
It is not possible to open the ECO II+ and reuse it! Every attempt to open the amalgam separator results in the malfunction of the device. Moreover, the required separation rate will no longer be achieved! PureWay.com...
Page 3
Remove the secure clamp, remove the adapter with the tube and tightly close the waste water outlet with the sealing plug. STEP INLET Remove the secure clamp and remove the adapter with the tube. STEP Remove the screws from the stainless-steel cylinders and remove them completely from the foundation brackets. PureWay.com...
Page 4
For Disposal see page 7: „Disposal of the full collection container“ STEP Fit the O-rings onto the ECO II+ „INLET“ and „OUTLET“ openings as shown. STEP OUTLET Put the fitting elements onto the ECO II+ Canister and secure them with the clip. PureWay.com...
Page 5
Put the fitting elements onto the ECO II+ Canister and secure them with the clip. Connect the ECO II+ with the adapter which was used with the ECO II and secure it with the secure clamp. Then connect the tube onto the adapter. PureWay.com...
Page 6
Check inlet and outlet of the ECO II+ for tightness! Suck in a large quantity of water (at least 0.5 gal or 2 l) to check the system for leakages. If leakages are found, check the hose connections. PureWay.com...
Page 7
STEP Need assistance installing your ECO II+? Put the amalgam Call 877.765.3030 and PureWay can assist separator and the you in finding a qualified technician to install styrofoam shells into your system! the box and close it.
Page 8
ECO II+ AMALGAM SEPARATOR Contact Us PureWay Compliance, Inc. 16225 Park Ten Place, Suite 830 Houston, TX 77084 877.765.3030 www.PureWay.com...