Page 2
40-549 User Manual PXI 5 Amp Power EMR Matrix Module pickeringtest.com Issue 2.3 November 2020...
Page 3
Pickering Interfaces. Technical details contained within this publication are subject to change without notice. ISO 9001 Reg No. FM38792 5 AMP POWER EMR MATRIX MODULE 40-549 REED RELAY MODULE 40-110/115/120/125 Page (II) Page (II)
If this product is heavy reference should be made to the safety instructions for provisions of lifting and moving. STATIC SENSITIVE To indicate that static sensitive devices are present and handling precautions should be followed. REED RELAY MODULE 40-110/115/120/125 5 AMP POWER EMR MATRIX MODULE 40-549 Page (IV) Page (IV)
Programming The Matrix ............4.2 Using IVI Driver, Direct Driver or VISA Driver .....4.3 Section 5 Connector Information ..............5.1 Section 6 Troubleshooting ................6.1 Section 7 Maintenance Information ............7.1 Relay Look-Up Tables ............7.1 5 AMP POWER EMR MATRIX MODULE 40-549 Page (V)
Page 7
THIS PAGE INTENTIONALLY BLANK 5 AMP POWER EMR MATRIX MODULE 40-549 Page (VI)
4. Printed Circuit Boards (PCBs) fitted with these devices must be stored and transported in anti-static bags. 2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579 5 AMP POWER EMR MATRIX MODULE 40-549 Page (VII) Page (VII)
Page 9
• For suitably equipped products in the event of an emergency press the red “emergency stop” button situated on the front of the unit. 2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579 5 AMP POWER EMR MATRIX MODULE 40-549 Page (VIII) Page (VIII)
Page 10
• Supported by PXI or LXI Chassis • 3 Year Warranty The 40-549 is a single pole power matrix module, suitable for switching inductive/capacitive loads up to 5A with 110VDC/250VAC hot switching and 400VDC/250VAC cold switching. It is available in the following configurations: •...
SECTION 1 - TECHNICAL SPECIFICATION pickering Specifications 5A Power EMR Matrix – 40-549 Relay Type Power Requirements The 40-549 is fitted with electro-mechanical power relays, gold clad +3.3V +12V -12V silver alloy. 1.5A 30mA Switching Specification Mechanical Characteristics Contact Type: Gold clad silver alloy Single slot 3U PXI (CompactPCI card).
Page 12
• Alternative relay types office. • Mixture of relay types Mating Connectors & Cabling • Alternative number of relays For connection accessories for the 40-549 modules please • Different performance specifications refer to the 90-008D 25-pin D-type Connector Accessories data...
Page 13
We are the only switch provider with in-house reed relay manufacturing capability via our Relay Division. These instrument grade reed relays feature SoftCenter™ technology, ensuring long service life and repeatable contact performance. To learn more, please go to: pickeringrelay.com pickeringtest.com 5 AMP POWER EMR MATRIX MODULE 40-549 Page 1.4...
Page 14
We have also published handy reference books on Switching Technology and for the PXI and LXI standards. To view, download or request any of our product resources, please visit: pickeringtest.com/resources pickeringtest.com 5 AMP POWER EMR MATRIX MODULE 40-549 Page 1.5...
The module comprises a single PCB populated with 1-pole electro-mechanical relays configured as a single 16x4 (40-549-001), single 8x8 (40-549-002), dual 8x4 (40-549-003) or a single 8x4 (40-549-004) matrix. The relays are energised via control signals from relay drivers U17 to U20. Each relay driver is loaded with serial data from PCI bridge U1 to operate the required matrix crosspoint via digital isolators U21 and U22.
LabVIEW Runtime Engine installer via the shortcut on the Programs>>Pickering menu. In the absence of LabVIEW the Runtime Engine is required to support the Pickering Test Panels application. REED RELAY MODULE 40-110/115/120/125 5 AMP POWER EMR MATRIX MODULE 40-549 Page 3.2 Page 3.2...
Panels can be opened simultaneously for all the installed cards. Figure 3.3 - General Soft Front Panel Selector More details how to use the GSFP can be found in the manual, via menu Help\Manual REED RELAY MODULE 40-110/115/120/125 5 AMP POWER EMR MATRIX MODULE 40-549 Page 3.3 Page 3.3...
Page 21
SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK 5 AMP POWER EMR MATRIX MODULE 40-549 Page 3.4...
For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads Also, it can be accessed from the DVD supplied with the product: <DVD_DRIVE>\downloads\Documentation\Software-Manual.pdf 5 AMP POWER EMR MATRIX MODULE 40-549 Page 4.1...
PROGRAMMING THE POWER MATRIX The 40-549-001 is a single pole switching matrix with 16 connections on the X-axis and 4 connections on the Y-axis. Connections are made by operating the relays at the crosspoints between X and Y lines allowing single X-Y connections, or X-X connections using a Y line as a path.
SECTION 5 - CONNECTOR INFORMATION pickering SECTION 5 - CONNECTOR INFORMATION FP_GND Figure 5.1 - Pinout: 5 Amp Single 16x4 Power Matrix 40-549-001: (25-pin Male D-type Connector Viewed From Front of Module) FP_GND Figure 5.2 - Pinout: 5 Amp Single 8x8 Power Matrix 40-549-002:...
Page 27
SECTION 5 - CONNECTOR INFORMATION pickering FP_GND Figure 5.3 - Pinout: 5 Amp Dual 8x4 Power Matrix 40-549-003: (25-pin Male D-type Connector Viewed From Front of Module) FP_GND Figure 5.4 - Pinout: 5 Amp Single 8x4 Power Matrix 40-549-004: (25-pin Male D-type Connector Viewed From Front of Module) 5 AMP POWER EMR MATRIX MODULE 40-549 Page 5.2...
Please note that the Diagnostic Utility cannot access cards if they are currently opened by some other application, such as the Test Panels or Terminal Monitor. REED RELAY MODULE 40-110/115/120/125 5 AMP POWER EMR MATRIX MODULE 40-549 Page 6.1 Page 6.1...
PCB. The tables can be used in the fault finding process and should be used in conjunction with the corresponding PCB layout diagrams to identify the position of faulty relays. REED RELAY MODULE 40-110/115/120/125 5 AMP POWER EMR MATRIX MODULE 40-549 Page 7.1 Page 7.1...
Need help?
Do you have a question about the 40-549 and is the answer not in the manual?