4.0 Electrical Installation
Please see the Quick Start Guide for UL Class 1 Division 2 installation instructions.
4.1 Wiring
4.1.1 Terminal Block
Operating Voltage
Maximum Surrounding Ambient Air Temp
Wiring Terminals
Wire Range
Tightening Torque
Temperature Rating of Field Installed Conductors
4.1.2 Power Supply Connections
Both power and data signals are connected to the terminal block. Figure 4-1 shows the
layout.
Figure 4-1
The radio modem requires power from an external source. The radio modem requires 10
to 30 VDC. Power use depends on the model:
ZXT9RM – 1.7 Watts typical, 5.8 Watts maximum.
ZXT24RM – 1.2 Watts typical, 3.5 Watts maximum.
Connect the positive and negative power leads to the Power In(+) and Power In (-)
terminals on the terminal block.
.
Section Four – Electrical Installation
10 to 20 VDC
74°C
Use Copper Wire Only, One Conductor Per Terminal
30 to 12 AWG
0.5 to 0.6 Nm
105°C minimum, sized for 60°C ampacity.
Terminal Block
Page
22
Document Number: pnZXTxRM-0712m