Orion Power Systems Edge Pro Series User Manual page 2

Line-interactive ups

Advertisement

8.
Serial Port
This port allows connection and communication from the DB9 serial on the computer to the UPS
unit. The UPS communicates its status to the software.
9.
Power On/Off Button
Press the power Button to turn the UPS ON or OFF.
10. Mute Button
The audible alarm can be turned off/on by pressing this button for 3 seconds, and can also show
page flipping by pressing this button for 1 second.
11. LCD Display
The LCD will display the UPS status.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indicators
Line mode
Alarm/Fault
Bat mode: battery capacity
Line mode:
1. Battery charging: cycle
lighting
2. Battery full charged:
lighting
3. Line mode without
charger: battery capacity
Line mode & Bat mode
Line mode
Initial
2th
3th
TECHNICAL SPECIFICATIONS
Model
EP700R
Capacity (VA)
700VA
Capacity (Watts)
420W
Input
Input Voltage Range
Frequency Range
Output
On Battery Output Voltage
On Battery Output
Frequency
Overload Protection
AVR Function
Boost Function
Buck Function
Physical
Total # of UPS
Receptacles
Maximum Dimensions
(H x D x W)
Weight (lbs.)
25
Battery
Sealed Maintenance Free
12Vdc
Lead Acid Battery
Typical Recharge Time
Warning Diagnostics
Indicators
Communication
Communication port
SNMP Management
Options
Environmental
Operating Temperature
Operating Relative
Humidity
Management
Auto-Charger
Sound disable
(Press the mute
key 3s to disable
and enable the
buzzer sound)
Load capacity
Bat mode
EP1000R
EP1500R
1000VA
1440VA
600W
900W
82V~148V
60Hz +/- 5 Hz
Sine Wave at 100-127Vac +/-10%
60Hz +/-1%
Yes
Yes
Yes
Nema 5-15R *8
3.5 in x 16.9 in x 17.25 in
29
36
24Vdc
8 Hours
LCD
HID USB/RS232
External SNMP Adapter, External Temp Probe
32℉ to 122℉ (0℃ to 40℃ )
0 to 90% NON-CONDENSING
Yes
Auto-Restart
Problem
Abnormal
Mains normal but not
Works in AC mode
The UPS will not turn on
Outlets do not provide
power to equipment
Bat-mode
Alarm
Alarm code A06
Alarm code A09
Alarm code A14
Alarm code A16
Alarm code A18
Fault
Fault code F06
Fault code F07
Fault code F08
Fault code F09
Fault code F11
Fault code F12
Fault code F13
Fault code F14
Fault code F15
Fault code F18
Fault code F19
Other
Software is inactive
EP2000R
1920VA
1200W
Power Master management software provides a user-friendly interface for your power systems. The
graphic user-interface is intuitive and displays essential power information at a glance. Please follow
procedure below to install the software.
37
Yes
TROUBLE SHOOTING
Possible Causes
1. AC Input missing
1. Check AC input connection.
2. Unplug the power cord of the UPS
2. Input Breaker is tripped
then press the circuit breaker knob.
The on/off Button is designed
Turn the UPS off. Wait 10 seconds
to prevent damage by rapidly
and then turn the UPS on.
turning it off and on.
The unit is not connected
The unit must be connected to a
to an AC outlet.
100-127V 50/60Hz outlet.
The battery is worn out.
Contact Technical Support.
Mechanical problem.
Turn the UPS off and unplug at least
Circuit breaker is tripped
one piece connected equipment.
due to overload
Unplug the power cord of the UPS then
press the circuit breaker knob.
Allow the unit to recharge for at
Batteries are discharged
least 4 hours.
Unit has been damaged
Contact Technical Support.
by a surge or spike.
Battery capacity is low
Battery disconnected
Over load occurs.
EPO active
Over temperature
INV soft start fail
Restart the UPS, if the fault is still,
INV volt high
contact Technical Support
INV Volt low
Your attached equipment may have
Output circuit short.
problems, please remove them and
check again.
Battery voltage is too high.
1. Shut down the UPS
2. Check the counts of Battery
Battery voltage is too low
3.Check battery connector when
use battery packages.
Battery is overcharge
Shut off non-essential equipment.
If this solves the overload problem,
Over load occurs.
the UPS will transfer to normal
operation.
load unbalance
Fan has been damaged.
Shut down the UPS, Replace the fan
1. Shut down the UPS. Restart the
UPS to Check the fan for operation
Over temperature
and if the ventilation hole has been
covered.
2. Contact Technical Support.
Connect the serial cable to the UPS
The serial cable is not
unit and an open serial port on the back
connected.
of the computer. You must use the
cable that came with the unit.
Shutdown your computer and turn the
The unit is not providing
UPS off. Wait 10 seconds and turn the
battery power.
UPS back on. This should reset the
unit.
SOFTWARE DOWNLOAD
Remedy