(Bit Address+Destination End Point =
0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x28
DS-100 AC load current (I) example:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x05) (Bit Address =0 ; Destination End Point =
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x4A
value will be 0)
(Bit Address =0;Destination End Point
range1~3)
( Command_Class_Meter_V3 = 0x32)
(Meter_Get = 0x01)
(Scale = A = 0x05)
(Meter report = Endpoint3)
command inquirer's Endpoint value)
(Command_Class_Meter_V3 = 0x32)
(Meter_Report = 0x02)
(Scale Bit2 = 1, Rate Type = 0x01,
Meter Type=0x01)
(Precision = 2, Scale Bit1Bit0 = 0x01,
Size = 2)
Parameter 3 = 0x00
Parameter 4 = 0x2B
2-3-5-5 Get power factor PF from endpoint
Meter_GET example:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05
(Bit Address+Destination End Point =
0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x30
DS-100 power factor report example:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
11
Current = 0x002B = 0.43A
(this is the endpoint of command inquirer,
here we assume endpoint is 5,if the
inquirer doesn't support multi Channel this
value will be 0)
(Bit Address =0;Destination End Point
range1~3)
( Command_Class_Meter_V3 = 0x32)
(Meter_Get = 0x01)
(Scale = PF = 0x06)