Mega 115V HXV Single Zone Wall Mounted Indoor Unit Error Codes
Table 25: Mega 115V HXV Single Zone Wall Mounted Indoor Unit Error Codes.
Error
Code
1
Indoor unit room temperature sensor error
2
Indoor unit inlet pipe sensor error
4
Float switch error (optional)
5
Communication error between indoor unit and outdoor units
6
Indoor unit outlet pipe sensor error
9
Indoor unit EEPROM error
10
Indoor unit BLDC motor fan lock
12
Indoor unit middle pipe sensor error
21
DC Peak (IPM Fault); Compressor DC voltage was too high
22
Current Transformer2 (CT2) error; Alternating current (AC) input too high
23
DC Link Low Volt
25
AC Low/High Volt
26
DC Comp Position Error (not providing rotation), Locking
27
PSC Fault; Current to inverter compressor between AC and DC converter circuit too high
28
Inverter compressor DC voltage is too high
29
Inverter compressor amperage is too high
31
Current-to-current transformer (CT) thermistor is too low
32
Inverter Compressor Discharge Pipe (D-Pipe) Overheat
40
CT Sensor Error; Thermistor is disconnected or shorted out
41
D-Pipe Sensor INV is disconnected or shorted out
44
Outdoor Air Sensor is disconnected or shorted out
45
Middle thermistor of outdoor unit condenser coil is disconnected or shorted out
46
Outdoor unit suction line thermistor is disconnected or shorted out
48
Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out
53
Communication failure from outdoor unit to indoor unit
60
Outdoor unit printed circuit board (PCB) EEPROM check sum error
61
Outdoor unit condenser coil temperature is too high
62
Outdoor unit inverter compressor PCB heat sink temperature is too high
63
Condenser coil pipe thermistor temperature is too low
65
Heat sink thermistor has disconnected or has shorted out
67
Outdoor brushless direct current (BLDC) fan motor lock error
Description
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
TROUBLESHOOTING
Figure 136: Mega 115V HXV Error Code Display LEDs.
No. of Times Indoor Unit
LED1
(Units Place)
1X
2X
4X
5X
6X
9X
-
2X
2X
2X
2X
2X
2X
2X
2X
2X
3X
3X
4X
4X
4X
4X
4X
4X
5X
6X
6X
6X
6X
6X
6X
Error Codes
LED 1
(UNITS PLACE)
LED 2
(TENS PLACE)
Receiver
LEDs Blink
LED2
(Tens Place)
-
-
-
-
-
-
1X
1X
1X
2X
3X
5X
6X
7X
8X
9X
1X
2X
-
1X
4X
5X
6X
8X
3X
-
1X
2X
3X
5X
7X
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents