Frigidaire PLKU1267D Use & Care Manual page 5

Household beverage cooler
Table of Contents

Advertisement

CO
CANISTER BRACKET INSTALLATION
2
• Align the two bracket holes with the screw anchor holes
located on the lower left side of the cabinet (the actual
screw anchor holes are centered behind the taped hole).
• Secure the CO
canister bracket (4) to the cabinet with
2
the two supplied mounting screws (5) using a Phillips
screwdriver.
DRIP TRAY ASSEMBLY INSTALLATION
• Make sure the notched back corners are on top and attach
the Drip Tray Bracket (3) to the door using four supplied
mounting screws (5).
• Drop the Drip Tray (1) onto the bracket.
• Drop the Drip Tray Cover (2) onto the drip tray.
(3) DRIP TRAY
BRACKET
FAUCET ASSEMBLY INSTALLATION
• Attach Faucet Knob (12) to Faucet & Shank Assembly (9).
• Slip the Faucet & Shank Assembly through the black plastic
Collar (10) and hole in the door.
• Thread on the large Shank Nut (11) and, using an
adjustable wrench, tighten until snug. DO NOT OVER
TIGHTEN.
(11) SHANK
NUT
CLIP ATTACHMENT TO DOOR PANEL
• Attach the two supplied hose routing clips (8) to the door
panel approximately 1~2 in (25~50mm) from the left door
edge. See delivery hose arrangement on page 6.
TM
(4) CO
2
CANISTER
BRACKET
(5)
MOUNTING
SCREWS
(2) DRIP TRAY
COVER
(1) DRIP
TRAY
(5) MOUNTING
SCREW
(12) FAUCET KNOB
(9) FAUCET &
SHANK ASSEMBLY
(10) P
LASTIC
COLLAR
(8) HOSE
ROUTING CLIP
DOOR PANEL
REGULATOR INSTALLATION
• Fasten the CO
regulator (13) to the CO
2
tightening the nut securely. DO NOT over tighten. Over
tightening may damage the gasket in nut of the regulator.
(23)
REGULATOR
RED HOSE TO REGULATOR CONNECTION
• Attach one end of the red hose (16) to the hose barb of the
CO
regulator (13). Secure the hose using one of the two
2
hose clamps (18) provided. Use pliers to snap the hose
clamp tight to assure that there is no gas leak.
RED HOSE TO COUPLER CONNECTION
• Fasten the other end of the red hose (16) to the keg
coupler (14) using the remaining hose clamp (18). Use
pliers to snap the clamp tight to assure that there is no gas
leak.
CLEAR HOSE TO COUPLER CONNECTION
• Attach the end of the clear hose (15) (beverage delivery
line) with the large wing nut to keg coupler (14). Be sure to
place the supplied rubber washer (17) inside the nut to
prevent leakage.
(15) CLEAR
HOSE
5
canister (19),
2
NUT
(29) CO
2
CANISTER
(13) REGULATOR
(18) HOSE CLAMP
(16) RED HOSE
(14) KEG COUPLER
(18) HOSE CLAMP
(16) RED HOSE
(14) KEG
COUPLER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plku1267ds0

Table of Contents