MHC Medical Products SureLife Premium SL-BW102V User Manual

MHC Medical Products SureLife Premium SL-BW102V User Manual

Talking wrist blood pressure monitor

Advertisement

Talking Wrist Blood Pressure Monitor
Premium Model

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SureLife Premium SL-BW102V and is the answer not in the manual?

Questions and answers

Susan Morin
February 15, 2025

How do I change the language to English

1 comments:
Mr. Anderson
February 15, 2025

To change the language to English on the MHC Medical Products SureLife Premium SL-BW102V, follow these steps:

1. Press and hold the “MEMO” button until the screen displays the current month.
2. Press the “MEMO” button to select the language.
3. Use the “MEMO” or “PAGE” button to choose language option 1 (English).
4. Press the “AVG” button to confirm the selection.

This answer is automatically generated

MacIntyre
May 14, 2025

When it starts to take a BP measurement, the “P” code displays then quickly goes out. Is this normal?

Summary of Contents for MHC Medical Products SureLife Premium SL-BW102V

  • Page 1 Talking Wrist Blood Pressure Monitor Premium Model...
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS • Infants, young children or individuals who cannot express their consent are not suitable to take blood pressure measurement. • Individuals with serious arteriosclerosis are not suitable to take blood pressure measurement. • Blood pressure readings may change in case of pregnancy. Pregnant women should consult their doctor before taking measurement.
  • Page 3 QUICK START GUIDE Avoid smoking, eating, drinking ca einated drinks or exercising for 30 minutes before taking measurement. 1. Sit upright in a chair at a table with both feet on the oor. 2. If necessary, roll up your sleeve to bare your wrist.
  • Page 4 OVERVIEW Monitor Display Sticker (1-99 readings) Note: Peel o and remove display sticker before use Features • One Touch Operation • Irregular Heartbeat Detector • Blood Pressure Mode and Clock Mode • 4 User / 396 Total Memory • 4 Alarm Clock Settings •...
  • Page 5: Battery Installation

    PREPARATION 2.1 Battery Installation 1. Remove the battery cover according to the direction of the arrow. 2. Insert 2 AAA batteries with the polarities in the correct direction. *Enlarged to show correct battery direction 3. Slide the battery cover to close until the lock securely clicks into place.
  • Page 6: Date And Time Setting

    2.2 Date & Time Setting The SureLife® Talking Wrist Blood Pressure Monitor has a built-in clock function. Activating the clock function allows the exact date and time of measurements to be recorded in the device’s memory. Note: The Date & Time is turned o by the factory and may be turned on, at the user’s discretion, using the instructions below.
  • Page 7: Alarm Setting

    7. Press the “ MEMO” or “PAGE ” button to turn the Clock Function “ON” or “OF”. Press the “ AVG” button to con rm. Note: If you select Clock Function “ON”, you will continue at the Alarm Setting section. Otherwise, setting will end. If clock setting is turned on, the unit will power o after 1 minute of inactivity.
  • Page 8 Note: • Press the “ ” button anytime during clock setting/alarm setting to start over if an error occurs. • Each alarm clock lasts 45 seconds, or you can turn it o by pressing the “ ” button. 2.4 Language/Sound Setting When a measurement is completed, the results will read aloud;...
  • Page 9: Taking Measurement

    TAKING MEASUREMENT Note: • Avoid smoking, eating, drinking ca einated drinks or exercising for 30 minutes before taking measurement. • Do not move or talk during measurement. 3.1 Sitting Correctly 1. Relax 2. Sit upright in a chair at a table with both feet on the oor. 3.
  • Page 10: User Setting

    3.3 User Setting This unit allows up to 4 users to store measurement records in di erent User Pages. Each User Page can store up to 99 measurements. ” button to switch between User Page 1, 2, 3 Press “PAGE and 4.
  • Page 11 Irregular Heartbeat This unit has a unique feature that alerts the user of irregular heartbeat detection during measurement. Note: An irregular heartbeat is de ned as a heartbeat rhythm that has a variation of more than 25% from the average rhythm detected during measurement.
  • Page 12 Regular but Below Normal Heartbeat If the monitor detects a pulse rate below 60 beats per minute during measurement, the monitor will ash between the pulse value and “LO” symbol. Example: (58 / LO) Regular but Above Normal Heartbeat If the monitor detects a pulse rate above 100 beats per minute during measurement, the monitor will ash between the pulse value and “HI”symbol.
  • Page 13: Memory Functions

    MEMORY FUNCTIONS After measurement, the last set of measured values will be saved automatically when the unit is turned o by pressing “ ” button or by automatic power o after 3 minutes. 4.1 View Past Readings 1. Press the “ MEMO” button to enter memory function. 2.
  • Page 14: Delete Past Readings

    Symbol on Display Average Values of One Hour One Day One Week 30 d One Month All Readings 4.3 Delete Past Readings ” button to select the User Page you 1. Press the “PAGE want to delete. 2. Press and hold the “ MEMO” and “PAGE ”...
  • Page 15: Troubleshooting

    TROUBLESHOOTING Problem Cause Solution No display when Have the batteries Replace new you press the run out? batteries. Power/Start Are the battery Re-align batteries button polarities wrong? in correct polarities. Check if the cu is “Err P” displayed Fail to in ate properly connected.
  • Page 16: Storage And Maintenance

    STORAGE & MAINTENANCE • Keep the unit away from direct sunlight, extreme temperatures, humidity or moisture • Use a dry, soft cloth to clean the unit, or if desired, use a cloth lightly dampened with water. • Do not use alcohol, benzene, thinner or other volatile liquids to clean the unit.
  • Page 17: Specifications

    SPECIFICATIONS Model No. Premium (SL-BW102V) Measurement Method Oscillometric Measurement Range Pressure: 20 – 280 mmHg Pulse Rate: 40 – 195 beats/min Accuracy Pressure: +/- 3 mmHg Pulse Rate: +/- 5% In ation Pump driven Pressure Detection Semi-conductor Power Supply 2 x AAA batteries Auto Power O 3 minutes after last operation Storage Environment...
  • Page 18: Warranty

    WARRANTY A Full 5-Year Warranty on Your Monitor The SureLife® Talking Wrist Blood Pressure Monitor is warranted to be free from defects in materials and workmanship within 5 years from the date of purchase. The monitor must be used in accordance with the instructions provided.
  • Page 19 MHC Medical Products 8695 Seward Road Fair eld, Ohio 45011 www.MHCmed.com Made in China. Distributed by MHC Medical Products, LLC. Package design © 2010 SureLife® is a trademark of MHC Medical Products. Manufactured in accordance with FDA and International Standards...