1/2”sq dr g3 air impact wrench

Advertisement

5.
MAINTENANCE
WARNING! Disconnect wrench from air supply before changing accessories, servicing or
performing maintenance. Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
5.1.
If the air system does not have an oiler lubricate the air wrench daily with a few drops of
Sealey air tool oil dripped into the air inlet.
5.2.
Clean the wrench after use. DO NOT use worn, or damaged sockets.
5.3.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or
type of hose connectors. To remedy, check the air supply and follow instructions in
Section 3.
b) Grit or gum deposits in the wrench may also reduce performance. Remove the strainer,
clean it and flush the wrench out with gum solvent oil or an equal mixture of SAE No 10
oil and paraffin. Allow to dry before use.
5.4.
For a full service contact your local Sealey service agent.
5.5.
When not in use, disconnect from air supply, clean wrench and store in a safe, dry,
childproof location.
Jack Sealey Limited 2013