Gentex Smarter Vision CO1209 Series Installation Instructions Manual

Gentex Smarter Vision CO1209 Series Installation Instructions Manual

Electrochemical carbon monoxide (co) alarm

Advertisement

Quick Links

ELECTROCHEMICAL TYPE SINGLE/MULTIPLE STATION
CARBON MONOXIDE ALARM, AC POWERED, WITH BATTERY BACK-UP
Installation Instructions - Owner's/User's Information Manual -READ CAREFULLY AND SAVE
INTRODUCTION CO1209 SERIES
The CO1209 electrochemical carbon monoxide (CO) alarm is for
use as an evacuation device in all dwelling units. The device has a
solid state piezo signal to warn and alert the occupants to the
presence of carbon monoxide.
Your CO alarm is designed to detect abnormal amounts of
carbon monoxide gas, only. Consequently, it is uncommon for
household sources of combustion, including properly functioning
household appliances, to produce sufficient levels of CO to cause an
alarm.
BASIC SAFETY INFORMATION
Dangers, Warnings, Cautions and notices alert you to important
operating procedures or to potentially hazardous situations. Pay
special attention to these items.
WARNING!
This CO alarm is listed for use in single-family and multi-family
residences, along with hotel, motels and other dwelling units.
This CO alarm will only indicate the presence of increased levels
of carbon monoxide gas at the sensor. Increased levels of carbon
monoxide gas may be present in other areas.
This CO alarm must receive continuous 120VAC, 60Hz , pure
sine wave electrical power. (battery is meant for emergency
back-up only). In order for the emergency battery back-up to work,
a new battery must be properly installed (see BATTERY
INSTALLATION section).
NEVER ignore your CO alarm if it sounds. Refer to IF YOUR CO
ALARM SOUNDS section for more information. Failure to do so
can result in serious injury or death.
Test this device once a week. If the device ever fails to test
correctly, replace immediately! If the device is not working
properly, it can not alert you to a problem.
This product is intended for use in indoor locations of family
dwelling units. It is not designed to measure CO levels in
compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards. Individuals with
medical conditions that may make them more sensitive to carbon
monoxide may consider using warning devices which provide
audible and visual signals for carbon monoxide concentrations
under 30 ppm. For additional information on carbon monoxide and
your medical condition, contact your physician.
MODELS
(SEE BACK OF CO ALARM FOR EXACT MODEL)
CO1209..........................120VAC, 60Hz
CO1209F........................120VAC, 60Hz with Form A/Form C auxilary
relay contact
NOTICE: In the event AC Power fails, a 9VDC battery will provide
proper alarm operation for a minimum of 24 hours.
HOW THE CO ALARM WORKS
GENERAL INFORMATION
NOTICE: CO problems can occur at any time.
When fully powered, the device samples the air and takes a new
reading about every 30 seconds. A microchip inside the unit stores
each reading and remembers the levels of CO it has been exposed
to over time. The CO alarm will sound when it has been exposed to
a critical level of CO (measured in parts per million or ppm) within a
specified time (measured in minutes). This CO alarm features a
permanently installed sensor, an indicator light and an 85dBA,
temporal 4 alarm horn. It also has a reset feature to temporarily
CO1209 SERIES
ELECTROCHEMICAL CARBON
MONOXIDE (CO) ALARM
& TANDEM WIRE CONNECTION
quiet the alarm horn. If critical levels of CO remain, the alarm will
re-activate and sound.
NOTICE: MALFUNCTION WARNING This unit performs a self-
diagnostic test. If the alarm malfunctions it should be replaced
immediately. See IF THE CO ALARM IS NOT OPERATING
PROPERLY for more information.
HOW TO TELL IF THE CO ALARM IS WORKING
PROPERLY
Your device is provided with an alarm horn and flashing red Light
Emitting Diode (LED) indicator, which flashes every 15-30
seconds, and a green AC power on LED and red LED for CO.
WHAT YOU CAN DO TO MAKE YOUR FAMILY SAFE
FROM CARBON MONOXIDE (CO)
a. Install CO alarms properly following the instructions in
this manual. Keep your units clean. Test your CO alarm
weekly and replace when it no longer functions.
As with any electronic product, CO alarms have a limited life,
it is recommended that CO alarms be replaced every five (5)
years. CO alarms that don't work cannot protect you.
b. Develop a family escape plan and practice it with your
entire family, especially small children.
Draw and post a floor plan of your home and find ways to
exit from each room.
Teach children what the CO alarm signal means, and that
they must be prepared to leave the residence by themselves
if necessary.
Decide on a meeting place a safe distance from your house and
make sure that all your children understand that they should go
and wait for you if there is a CO alarm.
Hold CO drills at least every 6 months to make sure that
everyone, even small children, know what to do to escape
safely.
Know where to go to call the fire department from outside your
residence.
WHAT TO DO IF THERE IS A CO EMERGENCY IN
YOUR HOME
If you have prepared family escape plans and practiced them with
your family, you have increased their chances of escaping safely.
Review the following rules with your children when you have CO
drills so everyone will remember them in a real CO emergency. If
alarm should sound:
a. Don't panic; stay calm. Your safe escape may depend on thinking
clearly and remembering what you have practiced.
b. Open windows or doors. Opening windows or doors can
significantly reduce CO levels.
c. Get out of the house following a planned escape route as quickly
as possible. Do not stop to collect anything or to get dressed.
d. Meet at your prearranged meeting place after leaving the house.
e. Call the Fire Department as soon as possible from outside your
house. Give the address and your name.
f. Never re-enter the building while the device is in alarm.
Contact your local Fire Department for more information on
making your home safer from CO and about preparing your family's
escape plans.
NOTE: Current studies have shown CO alarms may
not awaken all sleeping individuals, and that it is
the responsibility of individuals in the household
550-0498
Pg. C-1

Advertisement

Table of Contents
loading

Summary of Contents for Gentex Smarter Vision CO1209 Series

  • Page 1 CO1209 SERIES ELECTROCHEMICAL CARBON MONOXIDE (CO) ALARM ELECTROCHEMICAL TYPE SINGLE/MULTIPLE STATION CARBON MONOXIDE ALARM, AC POWERED, WITH BATTERY BACK-UP & TANDEM WIRE CONNECTION Installation Instructions - Owner's/User’s Information Manual -READ CAREFULLY AND SAVE INTRODUCTION CO1209 SERIES quiet the alarm horn. If critical levels of CO remain, the alarm will re-activate and sound.
  • Page 2: What You Need To Know

    Because CO may dissipate by the time an investigator arrives, it door is closed or only partially open. Even persons who are awake may be difficult to locate the source of CO. Gentex Corporation may not hear the sounding alarm if the sound is blocked by distance shall not be obligated to pay for any carbon monoxide (CO) or closed doors.
  • Page 3 To help prevent CO problems and reduce the risk of CO poisoning: These conditions can come and go, they are also hard to recreate Clean chimneys and flues yearly. Keep them free of debris, during a CO investigation. PLACEMENT OF CO ALARMS leaves, and nests for proper air flow.
  • Page 4: Important Consideration

    In addition to CO alarms outside of the sleeping areas, NFPA 720 requires the installation of a CO alarm on each additional level Figure 7 of the dwelling unit, including the basement. These installations are shown in Figure 5. The living area CO alarm should be installed in the living room or near the stairway to the upper level, or in both locations.
  • Page 5 NOTES ON TANDEM INTERCONNECTING MODELS DO NOT connect Gentex CO alarms to other manufacturers' CO alarms. No more than 12 Gentex models CO1209 may be tandem interconnected. WIRING TWO OR MORE ALARMS All units connected in tandem MUST get their power from the...
  • Page 6: Battery Installation

    CHECKOUT & TROUBLESHOOTING Do not tandem using both the red/yellow wire and brown/yellow wire. Only 1 tandem interconnect wire is needed between units. 1. Supply house power to the CO alarm, green indicator will be on. CAUTION: Failure to observe any of the conditions set forth may The red indicator light should flash approximately every 15-30 seconds, showing that the CO alarm is operating properly.
  • Page 7: Maintenance

    DO NOT TRY TO FIX IT YOURSELF. horn; use the reset feature. Removing the battery, removes Gentex recommends CO alarms be tested a minimum of once a your protection! See “If Your CO Alarm Sounds” for details week. The test feature of your CO alarm accurately simulates CO on responding to an alarm.
  • Page 8 Important Notice: These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no rep- resentations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns.

Table of Contents