Table of Contents

Advertisement

Quick Links

BJONG
User Manual
Firmware Revision: Flow-V1.0.1 / Standard-V1.0.1
App Revision: Easysetup 1.6.1
Manual Revision: V1.0 dtd 16/11/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BJONG and is the answer not in the manual?

Questions and answers

Summary of Contents for BM BJONG

  • Page 1 BJONG User Manual Firmware Revision: Flow-V1.0.1 / Standard-V1.0.1 App Revision: Easysetup 1.6.1 Manual Revision: V1.0 dtd 16/11/2020...
  • Page 2 B.M. TECNOLOGIE INDUSTRIALI s.r.l. Via Dell’ Industria, 12- 35035 RUBANO (PD)- ITALY Tel. +39(0)49-8841651 – Fax +39(0)49-8841654 e-mail: bm@bmtecnologie.it web: www.bmtecnologie.it Bjong – User Manual – V1.0 - pg.1...
  • Page 3 Documents revision REV. Type of Revision Approval Date First Version in English 16/11/2020 Bjong – User Manual – V1.0 - pg.2...
  • Page 4: Table Of Contents

    9.2 Discontinuous/Low power Mode 9.3 Data transmission 9.4 Freezing 10 Status led 11 App EasySetup 11.1 Device features for App EasySetup Installation 11.2 Installation and update 11.3 Authorizations 11.4 How does EasySetup works? Bjong – User Manual – V1.0 - pg.3...
  • Page 5 12.9 Variables log 12.10 Data 12.10.1 Real time data 12.10.2 Historical Data 12.11 Communication 12.11.1 Connection parameters 12.11.2 Data Transmission 12.11.3 SIM 12.11.4 Functional test 12.12 Alarms 12.12.1 Thresholds 12.12.2 Users 12.12.3 Download events Bjong – User Manual – V1.0 - pg.4...
  • Page 6 12.13.5 Battery calibration 12.13.6 Factory settings 12.13.7 Diagnostics 13 Conformity certificates of manufacturer 14 Maintenance 15 Service 16 Warranty 17 Disposal 18 Ordering Code 19 Appendix A – Batteries 19.1 Battery charging Bjong – User Manual – V1.0 - pg.5...
  • Page 7: Introduction

    The manual states the right way to use it. This manual describes all the functions of Bjong, referring to any specific version of hardware and/or software. Optional contents, dedicated functions or peculiar versions are NOT tagged specifically.
  • Page 8: General Information

    (on/off), etc. Bjong can be supplied by an internal primary battery to manage low consumption sensors for a long time, but it could also be supplied by an external battery, connected to a dedicated input, to manage sensors with higher power consumption.
  • Page 9: Main Sensors

    ✓ Calibration of numerical models. ✓ Long and short term measurement campaigns in aqueducts and sewers. ✓ Water balances. ✓ Pumping stations. ✓ Water treatment plants. ✓ Hydroelectric plants. ✓ Industrial processes monitoring. Bjong – User Manual – V1.0 - pg.8...
  • Page 10: Technical, Functional, Electrical And Mechanical Features

    2G and NBIoT (SIM holder included for standard SIM card) Wi-Fi Suitable for Android systems, for setup and data display ANTENNA Built-in Standard or high efficiency for transmissions in case of low signal. External Linear Up Polarization with 1.5 mt cable Bjong – User Manual – V1.0 - pg.9...
  • Page 11: Functional Features

    In, the user can download data and events, monitor the values read, diagnose the device. Bjong is connected to the user's device (tablet, smartphone) via a secure Wi-Fi connection. The downloaded files are in CSV format, easily processed in Excel.
  • Page 12 Alarm events can be sent via SMS to 3 users max. If the transmission fails, the device could be setup to retry sending SMS to selected intervals DATE/TIME SYNCHRONIZATION If enabled, time can be synchronized to a remote NTP server. Bjong – User Manual – V1.0 - pg.11...
  • Page 13: Dimensions And Fixing System

    4 Dimensions and fixing system Bjong was designed to be wall mounted with a bracket made of stainless steel. The bracket keeps the device in vertical position in order to reach external connectors easily. All dimensions are expressed in millimeters.
  • Page 14: Mounting Bracket

    This support is also particularly suitable when using external batteries, in order to simplify their replacement. Bjong – User Manual – V1.0 - pg.13...
  • Page 15: Combined Mounting Bracket

    It consists of two brackets with a coupler. The coupler allows two mounting brackets to be hold together, in order to reduce installation space and use a single quick-release system. Bjong – User Manual – V1.0 - pg.14...
  • Page 16: Case Opening And Closure

    5 Case opening and closure In standard operating conditions, it is not necessary to open or close the Bjong case. But it could be in these cases: ✓ Internal battery replacement ✓ SIM card Installation/replacement/removal ✓ Data transmission antenna replacement If necessary, unscrew the collar external clamp nut and use the quick-release system to remove the device.
  • Page 17 O-rings and drying bags must be replaced every time the case is opened. B.M. Tecnologie Industriali is not liable for any damage caused by failure to keep the case due to non-compliance with the indicated requirements. Bjong – User Manual – V1.0 - pg.16...
  • Page 18: Power Supply

    6 Power supply Bjong can be powered in three different ways: 1. Internal 3.6Vdc 2. Internal 8..24Vdc 3. External 8..24Vdc through POWER SUPPLY connector The internal power supply is intended to be supplied by primary (non-rechargeable) batteries inserted inside the instrument case. These are high-capacity batteries, almost completely free of self-discharge, which allow the instrument to remain active for medium-long term campaigns.
  • Page 19: Internal Connectors And Power Selector

    6.1 Internal connectors and power selector Inside the Bjong there are two power connectors (3.6Vdc e 8…24Vdc) and a power selector. The connection of any internal battery and the proper setting of the selector are made according to the customer request, so no need to be changed.
  • Page 20: Internal Battery Replacement

    A wrong disposition could cause an irreversible damage. 6.2 Internal battery replacement Bjong can be equipped wiht an internal primary battery. The battery pack can be composed of 2 or 4 cells, The configuration in series or parallel determines its voltage and overall capacity.
  • Page 21 The series or parallel configuration is determined by the type of battery holder. Contact the assistance service of B.M. Industrial technologies for different types of battery holders or in case of doubts about the possible configurations. Bjong – User Manual – V1.0 - pg.20...
  • Page 22: External Source Power Supply

    After replacing the battery, check the device connections. 6.3 External source power supply Bjong can be supplied by an external source, compatible with the features described in its dedicated chapter. The external power supply can be accessed by using the dedicated cable, connected to the POWER SUPPLY input.
  • Page 23: Wiring And Connections

    It is possible to request pre-wired connectors with additional cable lugs necessary for your purpose from the service or from your sales representative. If the Bjong is equipped with a pressure sensor, there will also be a hole for barometric compensation (vent). A specific hydrophobic membrane is inserted inside and allows the instrument to maintain the declared index of protection (IP).
  • Page 24: Wiring Id Colours

    RL2B (alarm) Pink Digital Event 1 Brown Digital Event 2 Configuration of pin AUX1…4: Configuration “A” Configuration “B” ConfigurationAUX1, AUX2 AUX1=RL1A AUX1=EXT_EVENT1 AUX2=RL1B AUX2=EXT_EVENT2 Configuration AUX3, AUX4 AUX3=RL2A AUX3=EXT_EVENT4: CHANGE MODE AUX4=RL2B AUX4=EXT_EVENT3 Bjong – User Manual – V1.0 - pg.23...
  • Page 25 The use of connectors not supplied by B.M. Tecnologie Industriali or incorrect connection with respect to what is indicated in this manual can cause irreversible damage to the instrument. Bjong – User Manual – V1.0 - pg.24...
  • Page 26: Sim Card

    8 SIM card Bjong is equipped with a SIM card holder for data transmission in 2G/NBIoT. To access the slot, follow these steps: 1. Open the case by acting on the external collar; 2. Remove the upper cover; 3. Unscrew the screws as shown in the picture to remove the battery pack (if present): 4.
  • Page 27 ...) are correct and that the data transmission tests are successful. The SIM used must not have the PIN code lock. Before installing a new SIM, make sure, for example using a mobile phone, that it is not protected. Bjong – User Manual – V1.0 - pg.26...
  • Page 28: Working Modes

    Battery life is highly reduced in this working mode. 9.2 Discontinuous/Low power Mode In low power Mode, Bjong is programmed to enter an energy saving mode in which any unnecessary internal and external peripherals are disconnected. In this way, the power absorption from the batteries is reduced to the minimum, ensuring greater autonomy.
  • Page 29: Data Transmission

    Data transmission can be activated both continuous and discontinuous mode. By activating this function, the Bjong will send the data via modem allowing remote monitoring of the values read. The user can choose the transmission frequency to prevent the system from being constantly connected to the Internet, with significant management costs in the case of time contracts with your telephone operator and in order to reduce the energy consumption associated with turning on the modem.
  • Page 30: Status Led

    10 Status led Bjong has four led indicating status and working mode of the device. Funzionalità Modalità Continua / Wake up Sleep mode Green Wi-Fi Fixed: Wi-Fi module is ON, you can Blinking: reading and logging Connection connect to the device...
  • Page 31: App Easysetup

    11 App EasySetup Bjong is completely configurable via EasySetup, a dedicated Android app that connects to the device via Wi-Fi network. Each device has a unique ID number consisting of an alphanumeric sequence of 12 characters (numbers from 0 to 9 and letters from A to F) shown on a label stick outside the case.
  • Page 32: Installation And Update

    The installation file is provided directly by the sales network or by the assistance service. EasySetup is pre- installed if a tablet for configuration is purchased together with Bjong. Download (copy) the APK installation file to a folder of the tablet's internal memory or SD card (if any).
  • Page 33: How Does Easysetup Works

    It is possible that not all buttons or not all options are enabled and selectable according to the device in use. For example, if the Bjong does not have the integrated pressure sensor available, the corresponding button to access the configuration will not be usable.
  • Page 34: Status Bar

    “Not connected” remains, but the name of the instrument (if set) and its identification will appear in the first row. In the example shown in the figure, Bjong has the name “ind12” and unique identifier “3C950900792C”. By connecting, in addition to the instrument name (if set) and its identification, the second line will indicate the date and time set on the Bjong to which you have connected.
  • Page 35: App Settings

    (see “operating mode” of the Bjong). To prevent the tablet from turning off the screen and pausing the application, it is possible to set the keeping of the display active while using the App.
  • Page 36: Codes And Passwords

    Using the appropriate connection button on the status bar, the App searches for available Wi-Fi networks and show only those whose name begins with BJONG and MKP in order to exclude those that are certainly not generated by Bjong and other managed instruments.
  • Page 37: Profiles Management

    ✓ Profile name: the name assigned to the profile, for simple identification; ✓ Instrument name and firmware version; ✓ MAC address; ✓ Last saved date. To access a series of available action for each profile, just press on it in the profile list. Bjong – User Manual – V1.0 - pg.36...
  • Page 38: Duplication And Association Of Profiles

    4. If needed, rename the device or make other changings (i.e. change ID); 5. Load the profile on the device. The same profile could be matched to different devices, only if they have the same hardware and the same firmware version. Bjong – User Manual – V1.0 - pg.37...
  • Page 39: Save" And "Save And Upload" Buttons

    The "save" button allows you to save the changes made only and exclusively on the tablet in use: the changes are saved only locally and not sent to the Bjong. This button is useful if you want to make multiple changes in multiple configuration tabs before loading the entire profile on the instrument.
  • Page 40: Configuration

    12 Configuration 12.1 Sensors connected to RS485 port This button on the left is used to access the settings of the RS485 port of the Bjong. There are two firmware versions of the instrument that allow different management of the port: EasySetup, based on the instrument firmware, will show different configuration screens.
  • Page 41 The Bjong connector has two pins for serial communication and two power pins whose voltage is that of the connected external battery. Before proceeding with the connection, make sure to make the correct connection of the external sensor to avoid, for example, inverting the polarity of the supply voltage.
  • Page 42 If selected, the first register has address 1. Error check: if selected, in case of error in reading the variable, the Bjong will generate and store an error event. Slave Type: in case of particular sensors, it is necessary to select the type.
  • Page 43: Rs485 Flow

    For this reason, before changing the variable settings, it is important to download the data saved on the Bjong memory in order to guarantee correct interpretation and saving. Also due to this, EasySetup displays a reminder requesting even if you intend to delete the historical data.
  • Page 44 Filling: tick the “Full pipe” box in case the flow rate calculation has to be done considering the maximum geometry level, ignoring the one read by the sensor. Level type: indicates how to determine the liquid level in the channel: Bjong – User Manual – V1.0 - pg.43...
  • Page 45 ✓ R is hydraulic radius (m) defined as a correlation between wet area and wet perimeter. It is automatically calculated; ✓ I is the bottom slope (m/m) Bjong – User Manual – V1.0 - pg.44...
  • Page 46 Flow direction: it is positive if water flows towards sloped sensor’s side. It is negative if water flows in the opposite way. If you select negative flow direction, velocity mark is inverted. (+ and -). Bjong – User Manual – V1.0 - pg.45...
  • Page 47 There may be a first header row which, if there are no numeric values, is ignored. Subsequent lines must contain two integer numeric values separated by “;”. The first value indicates the height of the channel, the second the respective width. Bjong – User Manual – V1.0 - pg.46...
  • Page 48 TTFM sensor configuration is possible only if it is connected to Bjong. Before setup, save and load the type of RS485 sensor, otherwise the device will not be able to communicate with TTFM.
  • Page 49 Enter the ones connected to the Bjong. Mounting mode: it the type of installation for the sensors: ✓ V – sensors on axis ✓ Z – opposite sensors Bjong – User Manual – V1.0 - pg.48...
  • Page 50 Low flow cutoff: it indicates the speed threshold, in m/s, below which the instrument displays the flow at 0 and stops the totalization. Scale factor: the correct scale factor calculated during calibration must be matched with each sensor. Depending Bjong – User Manual – V1.0 - pg.49...
  • Page 51 Tom Tos represents the transit time ratio calculated on the measured one. Under normal conditions the value should be 100% with a tolerance of +/- 3%. Differences greater than that indicate an error on installation or parameters settings. Bjong – User Manual – V1.0 - pg.50...
  • Page 52: Built-In Pressure Sensor

    During installation, take care the Tom Tos is close to 100% and the quality is as high as possible. 12.2 Built-in pressure sensor Bjong could be supplied with a built-in pressure sensor. Here are different pressure sensors available, depending on ranges (from 6 to 60 bar) and on installation needs. It is also possible to use external pressure sensors to be connected to analog inputs.
  • Page 53: Analog Inputs

    12.3 Analog inputs Bjong is equipped with 2 active analog inputs, with range 4-20mA and 0-10V (user can connect to the desired signal by using the dedicated wires – see wiring paragraph). Inputs can be configured independently, in order to guarantee to be the most suitable to the installation needs.
  • Page 54: Digital Inputs

    12.4 Digital inputs Bjong can be equipped with four digital inputs which, according to the operating mode set, allow it to operate as a status input or counter. Each digital can be configured in a different way than the others: ✓...
  • Page 55: Digital Events

    12.5 Digital events This section is dedicated to the of the behavior of Bjong when external digital events occur. Event 1, Event 2, Event 3: they allow the user to enable the storage of the occurrence of external digital events.
  • Page 56: Mathematical Functions

    A typical application is represented by the use with bidirectional flow meters. By appropriately connecting to digital 1 and 2 of the Bjong and enabling the mathematical difference function, it is possible to totalize the quantities of net water flow. The net value is saved on the second digital (DI2 or DI4). Another typical application could be that of having to perform the difference in flow rates between the system input and output recorded by meters with pulse output.
  • Page 57: Warm Up Times

    By setting the sampling per minute, it is easy to guess that a warm-up close to or greater than one minute is not possible: in these conditions, Bjong would not be able to go into sleep mode between one reading and another.
  • Page 58: Data

    12.10.2 Historical Data By historical data we mean all the values of the variables stored on the Bjong. Over 800,000 records can be stored on the instrument: with a sampling of 10 distinct variables every minute, there is a storage capacity of about 2 months.
  • Page 59 The waiting window provides evidence of the start and end dates of the currently copied data. The copying process can be stopped at any time. By downloading the data from Bjong into the App, they are copied and remain in the device internal memory.
  • Page 60: Communication

    12.11 Communication This section contains all the settings relating to the connection of Bjong to the Internet and the data transmission. The instrument, through the integrated modem, has the possibility of: ✓ Send stored historical data to the server ✓ Send alarm events to the server ✓...
  • Page 61 Port: port for connection. User, password: credentials for connecting to the MQTT broker. QoS, retain, time out, keep alive, clean session: you can choose typical configuration parameters communication with the MQTT broker. Bjong – User Manual – V1.0 - pg.60...
  • Page 62: Data Transmission

    Internet has several free NTP servers, despite the one factory set in Bjong. 12.11.2 Data Transmission In this section it is possible to set which data Bjong should send to the server and how. It is also possible to set SMS sending limits.
  • Page 63 Daily SMS sent: it is an unmodifiable counter of the messages sent during the current day. Enable sync: allows the user to enable automatic synchronization of the date with that provided by the server. Bjong – User Manual – V1.0 - pg.62...
  • Page 64: Sim

    To ensure correct access to the mobile network and optimize transmission, operators must be searched each time the instrument is moved or when there is frequent difficulty in data transmission. Bjong – User Manual – V1.0 - pg.63...
  • Page 65: Functional Test

    12.11.4 Functional test Bjong can perform a modem test to check that it is able to connect properly to the network. The test result provides: the operator, the network, the coverage signal and the registration. The test phases are displayed in a window.
  • Page 66: Alarms

    12.12.1 Thresholds Thresholds are the conditions under which one or more alarms are triggered. Bjong has a maximum of 8 thresholds that can be set on as many variables read. In the screen you can enable or disable the alarm relay and the list of settable alarms.
  • Page 67: Users

    In this menu it is possible to define a maximum of 3 users enabled to receive the warning SMS, sent by Bjong when exceeding one of the set thresholds. For each expected user it is possible to choose the name and telephone number.
  • Page 68: Service Function

    3. Wait for the completion of the operation Once the file has been uploaded to the Bjong, a short period of time is required for updating, restarting and restoring the Wi-Fi network. Before performing the update, make sure you have made a backup copy of the data.
  • Page 69: Wi-Fi Password

    ✓ punctuation and special characters! "# $% & '() * +, -. / :; <=>? @ [\\] ^ _` {|} ~ When setting the new password, the network of Bjong recreated. It is completely normal for the tablet to disconnect.
  • Page 70: Factory Settings

    By restoring the factory settings, all settings and data stored in the instrument's memory are deleted. Deleted data and settings cannot be restored. 12.13.7 Diagnostics This section includes the diagnostic tools of Bjong. With the current version of the application it is possible to manage the detection of the open case.
  • Page 71: Conformity Certificates Of Manufacturer

    13 Conformity certificates of manufacturer Bjong – User Manual – V1.0 - pg.70...
  • Page 72 Bjong – User Manual – V1.0 - pg.71...
  • Page 73: Maintenance

    By providing for appropriate disposal, you contribute to avoiding likely negative consequences for the environment and human health. If the instrument contains the lithium battery, it must be disposed separately. Bjong – User Manual – V1.0 - pg.72...
  • Page 74: Ordering Code

    Modem 2G/3G for global area Modem 4G for global area Secondary Radio Module No Radio Module Other (not available yet) Antenna Internal HF (high efficiency) Interna LF (standard) External (cable for connection) Bjong – User Manual – V1.0 - pg.73...
  • Page 75: Appendix A - Batteries

    4. LED2: RED= battery is charging; 5. When LED2 turns GREEN, battery is completely charged; 6. When charging is complete, disconnect the battery charger form mains and then remove all the used connectors and cables. Bjong – User Manual – V1.0 - pg.74...
  • Page 76 When the battery is completely down, charge it in max 7 days, otherwise it could be damaged and not reusable. Do not try to charge primary batteries. There is a danger of serious damage to property and people due to possible explosions. Bjong – User Manual – V1.0 - pg.75...