Ortech MH20-ST Instruction Manual page 3

Advertisement

Receptacles
MODEL
MH20-ST
INSTALLATION GUIDE
Connecting the Wires (choose A or B): A — One Cable (2-3 wires) Entering the Box
Connecting the Wires (choose A or B): B — Two cables (4 or 6 wires) Entering the Box
Connect the LINE cable wires to the LINE terminals:
• The WHITE wire connects to the WHITE terminal (Silver)
• The BLACK wire connects to the HOT terminal (Brass)
Connect the LOAD cable wires to the LOAD terminals:
• Remove the yellow sticker to reveal the LOAD terminals
• The WHITE wire connects to the WHITE terminal (Silver)
• The BLACK wire connects to the HOT terminal (Brass)
Connect the grounding wires (only if there is a grounding wire):
• Connect a 6" bare copper (or GREEN) 12 or 14AWG wire to the grounding
terminal on the GFCI. If the box has a grounding terminal, also connect a similar
wire to the grounding terminal on the box. Connect the ends of these wires to
the LINE and LOAD cable's bare copper (or GREEN) wire using a wire connector.
If these wires are already in place, check the connections.
info@ortechindustries.com
www.ortechindustries.com
13376 Comber Way
375 Admiral Blvd
Mississauga
Surrey BC V3W 5V9
Complete the installation:
• Fold the wires into the box, keeping the
grounding wire away from the WHITE and HOT
terminals. Screw the receptacle to the box and
attach the faceplate
• Go to the next step "Test Your
Work" (explained on the last page of this
instruction manual)
,
ON L5T 2N1
Instruction Manual
1-888-543-6473
1-888-541-6474