Download Print this page

Specification - Socket & See ENGINEER DMM Instruction Manual & Specification

6000 count, true rms digital multimeter

Advertisement

5. Specification

AC Voltage manual range
Range
Resolution Accuracy
600.0mV
000.1mV
6.000V
0.001V
60.00V
00.01V
6000.0V
000.1V
1000V
1V
AC Current µA manual range
Range
Resolution
600.0µA
000.1µA
6000µA
1µA
AC Current 10A manual range
Range
Resolution
6.000A
0.001A
10.00A
00.01A
DC Current mA manual range
Range
Resolution
60.00mA
00.01mA
600.0mA
000.1mA
Range
600.0Ω
Audible sound when
< 50Ω (approx)
+0.6% +3
digits
+0.6% +3
digits
+0.6% +3
digits
+1.0% +3
digits
+1.0% +3
digits
Accuracy
Range
+0.15% +5
60.00mA
digits
+0.15% +5
600.0mA
digits
Range
Accuracy
+1.5% +5
600.0µA
digits
+1.5% +5
6000µA
digits
Accuracy
Range
+0.15% +5
6.000A
digits
+0.15% +5
10.00A
digits
Continuity
Resolution
000.1Ω
0.001Ω
DC Voltage manual range
Range
Resolution Accuracy
600.0mV
000.1mV
6.000V
0.001V
60.00V
00.01V
6000.0V
000.1V
1000V
1V
AC Current mA manual range
Resolution
00.01mA
000.1mA
DC Current µA manual range
Resolution
000.1µA
1µA
DC Current 10A manual range
Resolution
0.001A
00.01A
Accuracy
+0.8% +6 digits
+0.8% +6 digits
+0.6% +2
digits
+0.6% +2
digits
+0.6% +2
digits
+1.0% +2
digits
+1.0% +2
digits
Accuracy
+0.15% +5
digits
+0.15% +5
digits
Accuracy
+0.12% +3
digits
+0.12% +3
digits
Accuracy
+1.5% +5
digits
+1.5% +5
digits

Advertisement