6000 count, true rms digital multimeter

Advertisement

Quick Links

ENGINEER DMM
6000 count, true RMS
digital multimeter
Instruction Manual & Specification

Advertisement

loading

Summary of Contents for Socket & See ENGINEER DMM

  • Page 1 ENGINEER DMM 6000 count, true RMS digital multimeter Instruction Manual & Specification...
  • Page 2: Operational Safety

    The ENGINEER DMM is designed to be used by skilled persons in accordance with safe methods of work. If the ENGINEER DMM is used in a manner not specified by Socket & See, the protection provided by it may be impaired.
  • Page 3 Do not operate the ENGINEER DMM with the battery cover off as this will compromise the insulated safety barrier. Do not use the tester in unfavourable environments such as: ● Wet conditions or in high humidity ● Dust and flammable gasses, vapours or solvent ●...
  • Page 4 2.3 Indication REL/ ∆ Adjust reading to zero Capacitor nF / µF Alternating Current (AC) Nanofarad / Microfarad Millifarad Direct Current (DC) Millivolt Hz/kHz/MHz Hertz / Kilohertz / Megahertz Volt Duty cycle Milliampere AUTO Auto range / Measurement µA Microampere CAT IV Overvoltage category 4 Ampere...
  • Page 5 NCV / NCF sensor LC Display Backlight / NCV detection LED Range button (press once) Manual decimal point mode for voltage, resistance and current measuring. Select button (press once). a) V range: DCV / ACV / Hz% / NCF b) Ohm range: Ohm / diode/ continuity / capacitance c) Current (µA / mA / 10A) range: AC / DC d) Wake up at auto power off mode e) Continuous operation / data logging...
  • Page 6 3 Usage Do not exceed the maximum input values. Extreme caution should be used when voltages higher than 25 VAC or 35 VDC could be present. When testing is complete, turn the rotary dial to the off position. To wake the tester from Auto Power Off (APO) mode press the select button >3 seconds. 3.1 Voltage Turn the rotary dial to the voltage position.
  • Page 7 continuity by touching the probe tips together. The value must be approximately <0.5Ω. If the reading is not zero press REL to adjust to zero. Connect the probes across the object to be measured ensuring a good clean contact. The LC display will show the measurement in Ohms and an audible tone will sound if the circuit is less than 50 ohms.
  • Page 8: Maintenance And Service

    4. Maintenance and Service 4.1 Battery Replacement Ensure the meter is disconnected from all live sources. Remove test leads and switch the tester off. Lift the tester stand and unscrew the battery cover screws. Lift the battery cover taking care to retain the screws. Replace the 9V battery ensuring correct polarity.
  • Page 9: Specification

    5. Specification DC Voltage manual range AC Voltage manual range Range Resolution Accuracy Range Resolution Accuracy +0.6% +2 +0.6% +3 600.0mV 000.1mV 600.0mV 000.1mV digits digits +0.6% +2 +0.6% +3 6.000V 0.001V 6.000V 0.001V digits digits +0.6% +2 +0.6% +3 60.00V 00.01V 60.00V...
  • Page 10 Diode Resistance manual range Range Resolution Accuracy Range Resolution Accuracy +10% +5 +0.7% +5 3.000V 0.001V 600.0Ω 000.1Ω digits digits +0.6% + 2 6.000KΩ 0.001KΩ digits Non-Contact AC Voltage detect +0.6% +2 LC Displays EF When >100 VAC LED blinks 60.00KΩ...
  • Page 11 Temperature measurement Range Resolution Accuracy -40°C to 0°C + (3% + 5°C) -40°C to 1000°C 1°C 1°C to 250°C + (2% + 2°C) -40°F to 32°F + (3% + 5°F) -40°F to 1832°F 1°F 33.8°F to 482°F + (2% + 2°F) Note: K type thermocouple probe (Ni-Cr and Ni-Si) is only applicable for the measurement of temperature range -40°C to 250°C.
  • Page 12 Ordering Information TRMS Digital Multimeter SOC/ENGINEERDMM SOC/TECC6 Soft Carry Case 3 Wire Non-Fused Distribution Board SOC/DLMPROLEAD Test Lead Set Combined DMM, Loop and Socket SOC/DLMPRO Tester SOC/PDLPRO High Resolution Loop Tester SOC/IRCPRO Insulation and Continuity Tester SOC/IRCCHECK Calibration Checkbox Non Trip Installation Testing SOC/CB400 Calibration Checkbox SOC/VIP150...