Caution for bodily injury
•Do not conduct any work at a location
where you do not have a sure footing.
(Failure to heed this caution may result in a fall.)
•Wear gloves when conducting work.
(Failure to heed this caution may result in injury
to your hands from sharp metal or other edges.)
Request during repair
•Inspect the grounding, and repair it if incomplete.
Make sure that the product operates correctly upon completion of repair. Clean the product as well as the sur-
rounding area, and then notify the customer of the completion of repair.

1. Specifications

Power
Model
Frequency
supply
name
(V)
Single-
GUF-50RDH3
phase
GUF-100RDH3
220-240
• The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic
chamber.
• The noise at the air outlets (at a 45° angle, 1.5 meters in front) is about 5-6 dB (A) higher than the values given in the table.
• The above values apply during Lossnay ventilation when the fan speed is set to high speed.
* Capacity in ( ) is heat recovery capacity by Lossnay core.
Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling:
Indoor: 27°C DB/19.5°C WB
Heating:
Indoor: 21°C DB/14.6°C WB
Incorrect handling of the product may result in serious injury
Caution
or damage to properties including buildings and equipment.
Power
Current
con-
(Hz)
(A)
sumption
(W)
1.15
235-265
50
2.20
480-505
Outdoor: 35°C DB/24°C WB
Outdoor: 7°C DB/6°C WB
♦ ♦
Prevent water leakage
•Before removing any of the water-related parts, com-
pletely drain the residual water from the piping.
•After the repair is complete, be sure to check the
drainage of the indoor unit and that no water leaks
Prohibited
from any of the piping connections.
(Water leakage may cause buildings to soil,
leading to secondary failure of other parts.)
Be sure to follow
this instruction.
External air load heat
processing capability (kw)
Air
volume
Cooling
capability
m
3
/h
L/S
5.29
500
139
(1.66)
10.81
1,000
278
(3.49)
— 4 —
Humidifying
Noise
volume
(dB)
Heating
capability
6.42
2.70
33.5-34.5
(2.25)
13.00
5.40
38-39
(4.70)
Be sure to follow
this instruction.
Equivalent
Weight
indoor unit
(kg)
capability
57
P32
98
P63