Setting the handle type:
This procedure will select the handle type: standard handle or handheld remote. The handle has to be
configured as a Handheld remote to enable the use of the auxiliary switch inputs that are used to control the
handheld relay junction box.
1. Press the sync button three times, the warm LED will flash.
2. Press the warm button once, you have now selected handle type configuration.
3. Press the sync button until the desired handle type configuration is displayed on the LEDs as
follows:
4. When the desired handle type configuration is displayed on the LEDs, press the warm button to
store it in memory. This will return you to the main menu (4 LEDs flashing).
5. Mark the handle type on the tag attached to the bottom of the handle.
Handle hardware verification:
This procedure will verify that the handle hardware is operating correctly.
1. Press the sync button four times, the troll LED will flash.
2. Press the warm button once, you have now entered hardware verification mode.
3. Move both handles to neutral.
4. Verify that all the 12 LEDs are lit. This indicates that all the LEDs are working.
5. Verify that the take LED is turned off while the take button is held down.
6. Verify that the sync LED is turned off while the sync button is held down.
7. Verify that the warm LED is turned off while the warm button is held down.
8. Verify that the troll LED is turned off while the troll button is held down. Steps 5-8 indicate that
the buttons are working.
9. Press and hold the sync and the warm buttons for 3-4 seconds.
10. Verify that the LEDs turn dim.
11. Press and hold the sync and the warm buttons for 3-4 seconds.
12. Verify that the LEDs turn bright.
13. Move the port handle to full ahead.
14. Verify that the take LED is lit. This indicates that the potentiometer is reaching the full ahead
voltage reading.
15. Move the port handle to full astern.
16. Verify that the sync LED is lit. This indicates that the potentiometer is reaching the full astern
voltage reading.
17. Move the port handle to neutral.
18. Move the stbd handle to full ahead.
19. Verify that the warm LED is lit. This indicates that the potentiometer is reaching the full ahead
voltage reading.
20. Move the stbd handle to full astern.
21. Verify that the troll LED is lit. This indicates that the potentiometer is reaching the full astern
voltage reading.
22. Move the stbd handle to neutral.
23. Press and release the sync and the warm buttons. This will exit the hardware verification and
bring you to the main menu (4 LEDs flashing).
24. Turn the system off and back on to operate the newly configured handle.