2. No Power
(1) Symptom
1) Doesn't minute discharge at module.
2) Non does not come in into the front LED.
(2) Check following
Is plug in power cord?
Is the Line Filter and Power
Board Cable connected?
Is the Fuse(F101) on
Power Board normal?
Is the Power Board and 13P of
VSC Board Cable connected?
After the cable connect is removed
to Power Board(except the SC101
connection cable), the AC voltage
marking is authorized on manual.
When ST-BY 5V is not operated,
replace Power Board.
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Yes
Yes
Yes
Yes
No
Plug in power cord.
No
Connect the Cable.
No
Replace the Fuse.
No
Connect the Cable.