All manuals and user guides at all-guides.com Power Analyzer Operating Instructions NORMA 4000 NORMA 5000 LEM NORMA GmbH Liebermannstraße F01 CAMPUS 21 A-2345 Brunn am Gebirge AUSTRIA Tel.: +43(0)2236-691-0 E-Mail: lno@lem.com Internet: www.lem.com...
View the measured values for the individual channels ....40 8.2.2 View totals of all measured values..........42 8.2.3 Compare measured values............43 8.2.4 View fundamentals ............... 44 8.2.5 User defined screen view.............. 45 Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 4
15.3 Packaging....................68 15.4 Housing ..................... 68 15.5 Electronic components ................68 Technical Data ....................69 16.1 Technical data NORMA 4000 ..............69 16.2 Technical data NORMA 5000 ..............72 16.3 Block diagrams..................75 Service and Accessories.................. 78 17.1 Instrument ....................78 17.2 Accessories ....................
Text formats Format Description Detail Names of software and operating elements, lettering on the device as well as numbers and text shown on the display are printed in italics. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Ensure that the power and connecting cables as well as all accessories used in conjunction with the device are in proper working order and clean. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 7
If you are in doubt as regards the safe operation of the device, immediately shut down the unit and the respective accessories, secure them against inadvertent switching on and bring them to an authorised service agent. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Do not remove the cover. Refer servicing to qualified personnel. Indoor use only The device may only be used indoors. Conformity mark re. EC Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Serial interface (RS 232) Power switch I: ON 0: OFF Mains connection Input for external synchronisation signal IF2 network adapter (LAN) (optional) Warning regarding max. voltage to earth Warning symbol; danger, observe operating instructions Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Channel Setup Menu bar with menu items Status Description Memory record active Wait for Trigger start condition(memory) Measurement active (Run mode) Measurement stopped (Hold mode) ∫ Integration of selected values active Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 11
The assignment of the function keys (9, page 8) varies, depending on the current menu. The current key assignment is shown on the assignment bar (10, page 8) located above the function keys. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
When extending the range using third-party shunts or clamp the extra errors due to these devices should be considered. The device caters for simultaneous measuring in up to 6 channels. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Set the power switch at the rear of the housing to position "0". If the device is not to be used for a prolonged period of time, disconnect the plug from the mains socket. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
3-phase power cables for this measurement should be connected to the measuring channels 1 to 3, so that the efficiency can be calculated and displayed directly on the device. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
VOLTAGE 1000 V max 1000 V max PROBE PROBE EXT.SHUNT EXT.SHUNT 10 V max 10 V max CURRENT CURRENT 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
We recommend using MCS measuring leads for triaxial shunts and MCP leads for planar shunts. Triaxial shunts are equipped with guard connectors in the plugs, while planar shuts are equipped with guard sockets. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
VOLTAGE 1000 V max 1000 V max PROBE PROBE EXT.SHUNT EXT.SHUNT 10 V max 10 V max CURRENT CURRENT 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
VOLTAGE 1000 V max 1000 V max PROBE PROBE EXT.SHUNT EXT.SHUNT 10 V max 10 V max CURRENT CURRENT 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
VOLTAGE 1000 V max 1000 V max PROBE PROBE EXT.SHUNT EXT.SHUNT 10 V max 10 V max CURRENT CURRENT 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
VOLTAGE 1000 V max 1000 V max PROBE PROBE EXT.SHUNT EXT.SHUNT 10 V max 10 V max CURRENT CURRENT 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
VOLTAGE 1000 V max 1000 V max PROBE PROBE EXT.SHUNT EXT.SHUNT 10 V max 10 V max CURRENT CURRENT 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
10 V max 10 V max 10 V max CURRENT CURRENT CURRENT CURRENT 10 A max 10 A max 10 A max 10 A max ALL INPUTS MAX 1000V CATII TO Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
300 ms of configuration 1:W3, and the new average time is displayed. Example: 309.9 ms at 22.585 Hz, corresponding to 7 periods. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
For instructions on how to configure the PI1 process interface, please refer to chapter 9: "PI1 Process Interface (optional)", page For instructions on how to delete a configuration, please refer to chapter 7.10 ”Delete configuration", page 37. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
PC, you must configure the parameters for the data exchange. This procedure consists of the following steps: Configure external printer Configure interface to PC Configure RS 232 Configure IEEE488 device address Configure LAN network addresses Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 26
IEEE488 interface (optional) USB2.0 interface (optional) Ethernet (LAN) interface (optional) SCPI Standard set of commands D5255S Previous set of commands (emulation) D5255T Previous set of commands (emulation) D5255M Previous set of commands (emulation) Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 27
A list with available addresses is displayed. Select an address that has not yet been assigned at the GPIB bus and confirm with Enter. The selected address is shown in line GPIB. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Call up Timing & Move the cursor to menu item Timing & Sync Setup and press Sync Setup Enter. The Timing & Sync Setup menu is displayed. The value in column Tavg[s] is highlighted. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 29
Enter the exponential power and confirm with Enter. Move the cursor to the return field of the calculator and press Enter. The average time is shown in column Tavg[s]. Save the settings with SAVE in the desired configuration. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 30
The low-pass filter enables you to modify signals with high filter harmonic content (e.g. PWM) so that they are synchronised to the resulting fundamental. This ensures that all measured values refer Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Move the cursor to the next field and repeat the above step until the correct date and time are shown. Menu field Clock Setup shows the time in hours, minutes and seconds. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Automatic range First field in column Auto is highlighted. adjustment (Auto) Press Enter. Select ON and confirm with Enter. The selected settings are shown in column Auto. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 33
The parameters of the formula must be entered as follows: scale factor x transducer ratio whereby scale factor: generally "1.0000" (one) transducer ratio: current (in ampere) to voltage (in volt) Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 34
Save the settings with SAVE in the desired configuration. Call up Voltage Call up Current Channel Setup. Channel Setup Note To configure the voltage channels, proceed as described for the current channels. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Press Enter, select ON and confirm with Enter. If you wish to configure all three current channels in this way press Set All. Save the settings with SAVE in the desired configuration. Auto range is now enabled. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Active power P1 to P3 and the sum power are preselected. Analyzer is switched on; start screen is displayed. Call up Integration Setup Press function key WAV. The integration symbol is displayed in the assignment bar for function keys. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 37
Press Enter, select ON and confirm with Enter. The integrations function is now enabled . If you want to disable it, select OFF and confirm with Enter Save the settings with SAVE in the desired configuration. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 38
Stop when key pressed (Key F2) ti-int Stop after time window -Date- Stop on date and time (only active at Trig time) after -time- Integrations time window in sec. ((only active at Trig ti-int) Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
If you do not keep this rule you will get results (frequencies or waveforms) that do not exist in truth (=Aliasing). Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 40
Note To work in the “undersampling mode” the anti-aliasing filter has to be turned OFF at the current and voltage channel (see chapter 7.6 “Configure current and voltage channels“ page: 30). Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
If you want to measure with external shunt or probe please make sure that there is no signal connected at the direct current inputs. Signals on both inputs (external- and direct current input) can damage the measurement unit. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Details regarding the voltage values, e.g. for channel 2, are shown. Display Description Rectified mean value 2 rm Mean value Crest factor 2 cf Form factor 2 ff Positive peak value 2 p+ Negative peak value 2 p- Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 43
Angle between U2 and I2 Press function key Detail again. Details regarding the measured values for phase-to-phase voltage are displayed. To return to the measured values for channel 2, press function key Detail again. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
. three times (or again) The efficiency and the total active power are displayed. Note The efficiency screen and totals channels 4-6 screen only appear if there are 4 to 6 power phases equipped Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
The power and power factor values are displayed. Display Description ... P Power at channels 1 to 3 λ ... λ Power factors at channels 1 to 3 To select channels 4 to 6, repeatedly press key WAV. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Press function key rms/h01. Detailed measured values in connection with the fundamentals at channel 3 are shown. Press function key Detail. Details of the voltage of the fundamental at channel 3 are shown. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Note If you enter the user defined screen the first time it is empty, showing dashes. In all other cases it shows the last saved configuration or the recently selected values. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 48
3 numeric values, double size 6 numeric values, common size (7mm) 9 numeric values, with size 5mm Press function key 3/6/9 User defined values are shown in desired size . Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
1...n and WAV to call up the graphs desired values, e.g. values measured at WAV power. Press measuring key Vector graphs. The measured values are shown in the form of vector graphs. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Press measuring key Oscilloscope curves. The measured values are shown in the form of oscilloscope curves. To view the details regarding a measured value, press function key Detail. The display shows the measured voltage. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
1...n and WAV to call up the desired values, e.g. current measured at channels 1 to 3. Press measuring key Recorder. The display shows a recording of the measured values. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
By using the cursor keys, you can adjust the positions of the axes. Press function key lin/log. The scale of the graph changes from linear to logarithmic or vice versa (here: change to logarithmic). Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 53
The default frequency range is set to maximum half of the Set frequency sampling frequency. range Important For signals with a lower frequency (e.g. 10 Hz), the frequency range must be adjusted, as measurements would otherwise be inaccurate. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
8.4.2 Harmonic Order mode View harmonics Press function key mode to call up a table showing the harmonics. The table shows the integer harmonics (here: voltages of the individual harmonics on channel 1). Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
The harmonic spectrum can be viewed in percentages of View spectrum fundamental H01. relative to H01 Note This view is important for the analysis of the input signal. Press function key mode. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
A key for the calculation of the electrical work is shown in the assignment bar for function keys. Press function key ∫. The assignment bar shows the functions used for the calculation. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 57
The totals of the reference power are shown. Press function key ∫. The totals of the output power are shown. To return to the overview of measured values for the selected channel, press function key ∫ again. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Check whether a printer is connected. Ensure that the interface is properly configured (see chapter 7.3: "Configure data transfer to printer and PC", page 23.) Press measuring key Print. The measured values are printed. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
± 10V DC output or a frequency output. Rotational speed The speed is measured by means of an incremental encoder with TTl or AC output; alternatively, an analog signal, e.g. from a speedometer might be used. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
(Pref) If you have already saved a configuration that suits the measuring layout: press function key LOAD, select this configuration and confirm with Enter. Adjust configuration as described below. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 61
To configure the device, adjust the settings in line Drv1 (for motor 1): Column Settings Description Type Motor Generator PPairs 1 ... 999 Number of pole pairs Pref P ... P3 Reference power for efficiency calculation Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 62
Move the cursor to a field in line A1 and press Enter. A list of possible options is displayed. Select a value and confirm with Enter. The value is now shown in the display field. Configure analog outputs A2 to A4 accordingly. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Press measuring keys 1...n to view the values of the respective channels. Press function key el/mech. View mechanical The measured values of motor 1 are shown. values Press measuring keys 1...n to view the values of the respective inputs. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 64
View all torques Press measuring key WAV. The torques of motors 1 to 4 are shown. Press key WAV again. The rotational speeds of motors 1 to 4 are shown. View all speeds Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
On the other hand, ensure that the resolution is sufficient to measure the frequency at low motor speeds. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
± 8000 counts for ± 10 V, 1 count ≈ 1.25 mV Rise time 10...90 %: approx. 10 ms Response time to ± 0.2 %: 25 ms to ± 1.0 %: approx. 20 ms Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
ω ϕ ω phase angular: ω 10.5 Uncertainty of measurement Uncertainty of × measurement - power: Uncertainty of measurement - voltage Uncertainty of measurement - current Uncertainty of measurement - angle Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
2 years. The device can be calibrated by the manufactorer service department or any other calibration specialist. 14 Maintenance Ensure that the ventilation slots are not blocked. Otherwise, the device is maintenance-free. Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
The housing is made in metal and can be recycled. 15.5 Electronic components The electronic components including the power adapter, filter, plug-in modules and wires have a weight of approx. 1500 g and a volume of approx. 3000 cm Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
128 MB additional memory for EA 1010 Z NORMA 5000 Rs232 cable 1,5m length 1:1 connected EA 1011Z LAN cable 2m length, crossed EA 1012Z USB cable 1,5m length, A to B plug EA 1013Z Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
LNO test report Cal 500 Recalibration of a shunt of up to 500A EA 1075 Z Cal 1500 Recalibration of a shunt of up to 1500A EA 1076 Z Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 82
All manuals and user guides at all-guides.com Service and Accessories Power Analyzer NORMA 4000, NORMA 5000 EO1111G REV G...
Page 83
All manuals and user guides at all-guides.com Printed in Austria / Gedruckt in Österreich / Imprimé en Autriche / Impreso en Austria / Stampato in Austria LEM NORMA GmbH Distributor / Vertragshändler / Distributeur / Distribuidor / Distributore Liebermannstraße F01, CAMPUS 21...