Chemglass CHEMcell CLS-1200-2CH Operation Manual

Chemglass CHEMcell CLS-1200-2CH Operation Manual

Temperature control module

Advertisement

Quick Links

C
L
S
-
1
2
0
C
L
S
-
1
2
0
C
L
S
-
1
2
0
O
P
E
R
O
P
E
R
O
P
E
R
3800 North Mill Road • Vineland, NJ 08360 • USA
Tel: 1-800-843-1794 • Fax: 1-800-922-4361
Web: www.cglifesciences.com
C
C
C
T
e
m
p
e
T
e
m
p
e
T
e
m
p
0
-
2
C
H
0
-
2
C
H
0
-
2
C
H
A
T
I
O
N
S
A
T
I
O
N
S
A
T
I
O
N
S
H
E
M
c
e
l
H
E
M
c
e
l
H
E
M
c
e
l
r
a
t
u
r
e
r
a
t
u
r
e
e
r
a
t
u
r
e
M
o
d
u
l
e
M
o
d
u
l
e
M
o
d
u
l
e
For Serial Number:
M
A
N
U
A
M
A
N
U
A
M
A
N
U
A
l
l
l
C
o
n
t
r
o
l
C
o
n
t
r
o
l
C
o
n
t
r
o
l
L
L
L
Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHEMcell CLS-1200-2CH and is the answer not in the manual?

Questions and answers

Summary of Contents for Chemglass CHEMcell CLS-1200-2CH

  • Page 1 ™ ™ ™ For Serial Number: 3800 North Mill Road • Vineland, NJ 08360 • USA Rev. A Tel: 1-800-843-1794 • Fax: 1-800-922-4361 Web: www.cglifesciences.com...
  • Page 2: Table Of Contents

    Table of Contents: General Description………………………………….………………… page 3 Specifications……………………………………………………page 3 Features………………………………………………..…….…...page 3 Additional Products………………………………….…..……..page 3 Unpacking Instructions…………………………….…………..……….page 3 Front and Rear Views………………..…………..……………..……… page 4 Set-Up Guide………….…………………………………………..….…..page 4 Figure 1 – Cell Culture Bag/Vent Heater ….………………..page 4 Figure 2 – Tray attached to Base..………….……….……… page 5 Figure 3 –...
  • Page 3: General Description

    General Description The CG Life Sciences CHEMcell Temperature Control Module has an easy to read digital display with a ramp to set point feature. A 120VAC outlet for connection of the heater cord from either CLS-1200-250 or CLS-1200-300 Tray. Two 5vdc connections are provided for CLS-1200-FH, Filter Vent heaters. Specifications: •...
  • Page 4: Front And Rear Views

    CLS-1200-2CH, Temperature Control Module REAR VIEW FRONT VIEW SET-UP Guide (refer to Fig. 1, 2 & 3) 1. Place Controller on a flat stable surface. 2. Ensure adequate space around controller. 3. Plug Controller into suitable electrical outlet. 4. Place Vent Heater (if applicable) over Vent Filter and connect end to ‘Filter Vent Heater’ outlet on Front of Controller.
  • Page 5: Operating Instructions

    (RTD - Pt100 Sensor adhered to Tray) connector Tray Heater Plug Figure 2 – Tray attached to Chemcell Base Main Power Switch Filter Vent Heater, 5Vdc (CLS-1200-FH) Arrow Control Key Tray Heater (CLS-1200-250 or Down CLS-1200-300) Arrow RTD Sensor Pt100 (CLS-1200-RTD) Figure 3 –...
  • Page 6: Quick Reference Guide

    Quick Reference Guide – Entering Setpoint Temperature Value and Adjusting the Displayed Temperature Value (see Fig. 3) ❖ Entering Setpoint Temperature Value: [Default Setpoint is 37.0°C] 1) Press and hold the Control Key While holding in the Control Key, press the Up Arrow to increase or the Down Arrow to decrease the Setpoint Temperature value.
  • Page 7: Autotuning

    Autotuning (refer to Fig. 3) • Autotune is feature built into the temperature controller that automatically calculates the tuning parameters (i.e. delay times, heating efficiency, heating load, etc.) for any type heater. After the autotune procedure is complete and the tuning parameters are selected, the controller automatically loads them into its memory for current and future use.
  • Page 8: Autotuning The Controller For Very Fine Control

    ❖ In most cases if the over temperature protection circuit is active, it must be inactivated before starting this procedure. Set the equipment up in the exact configuration it will be used. Ensure all connections to the Temperature Control Module. Turn controller on an enter the desired set point temperature.
  • Page 9: Overtemperature Protection Circuit

    Over-Temperature Protection Circuit ❖ The temperature controller is equipped with an over-temperature protection circuit that turns off heating any time the temperature read-out goes 10°C above the entered setpoint. When the temperature cools below the 10°C threshold, the circuit is reset and the controller returns to operating normally.
  • Page 10: Ramp And Soak Features

    Ramp and Soak Features Page 10...
  • Page 11: Important Points To Know

    Important Points to Know Page 11...
  • Page 12: Activating/Programming Ramp-To-Setpoint Feature

    Activating & Programming the Ramp-to-Setpoint Feature Deactivating the Ramp-to-Setpoint Feature Troubleshooting Resetting the Controller to Original Factory Settings See Autotune section Page 12...
  • Page 13: Resetting Controller To Factory Default Settings

    Resetting Controller to Factory Default Settings Page 13...
  • Page 14: Service/Maintenance

    Warranty: Chemglass, Inc. guarantees this unit against defects in material and workmanship for a period of one year from the date of purchase. If the unit should malfunction, it must be returned for evaluation. If the unit is determined to have a defect in materials or workmanship, then it will be repaired or replaced at no charge.

Table of Contents